• Title/Summary/Keyword: probe image

Search Result 211, Processing Time 0.025 seconds

Study on the histomorphometry of guided bone regeneration using automated image analysis system (자동 영상분석 계기를 이용한 골 유도재생능력의 분석에 관한 조직계측학적 연구)

  • Kim, T.I.;Ku, Y.;Rhyu, I.C.;Chung, C.P.;Han, S.B.;Choi, S.M.;Son, S.H.
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.771-778
    • /
    • 1996
  • The assessment of alveolar bone changes on dental radiographs to indicate progression of periodontal diseases or healing response to therapy is routine procedure. However, the diagnostic accuracy in detecting small alveolar bone changes is very limited. Recently, guided bone regeneration therapy is popular, but the quantification of new bone is somewhat difficult with conventional evaluation method. To quantificate the amount of new bone, various evaluating methods have been introduced including histomorphometry, radiomorphometry, biochemical analysis, X-ray probe microanalysis, scanning electron microscope backscatter method. In this study, guided bone regeneration using resorbable membrane with & without PDGF-BB is quatificated through histomorphmetry to evaluate the efficacy of histomorphometric analysis. 4 beagle dogs and 8 Sprague-Dawley rats were selected as experimental animals. In beagle dog experiment, $4{\times}4mm$ Class II defects were created in maxillary both second premolars, and biodegradable membrane containing PDGF-BB(experimental group) were covered over one defect, and same membrane without PDGF-BB(control group) were covered over the other defect. At 2 weeks, 5 weeks after surgery, each beagle dogs were sacrificed, and the tissues were treated by undecalcified fixation. In Sprague-Dawley rat experiment, 5mm round defect were created in temporal bone, the same membranes were covered on the defects. At 1 week, 2 weeks after surgery, each rats were sacrificed, and undecalcified fixation were taken. After grinding tissue specimen, we analyse them histomorphometrically using image analysis system. In beagle dog 2 weeks specimens, new bone formation area were $0.03123mm^2$ in experimental group,and $0.03012mm^2$ in control group. At 5 weeks specimens, $0.15324mm^2$ in experimental group, and $0.09123mm^2$ in control group. In Sprague-Dawley rat specimens, new bone fomation area were $0.20448mm^2$ in 1 week experimental group, $0.03604mm^2$ in 1 week control group. At 2 weeks specimens, $0.46349mm^2$ in experimental group, $0.17741mm^2$ in control group. The results indicated that histomorphometric analysis of new bone formation using image analysis system is very effective quantification method to evaluate the efficacy of treatment modalities.

  • PDF

A Study on Image Analysis of Graphene Oxide Using Optical Microscopy (광학 현미경을 이용한 산화 그래핀 이미지 분석 조건에 관한 연구)

  • Lee, Yu-Jin;Kim, Na-Ri;Yoon, Sang-Su;Oh, Youngsuk;Lee, Jea Uk;Lee, Wonoh
    • Composites Research
    • /
    • v.27 no.5
    • /
    • pp.183-189
    • /
    • 2014
  • Experimental considerations have been performed to obtain the clear optical microscopic images of graphene oxide which are useful to probe its quality and morphological information such as a shape, a size, and a thickness. In this study, we investigated the contrast enhancement of the optical images of graphene oxide after hydrazine vapor reduction on a Si substrate coated with a 300 nm-thick $SiO_2$ dielectric layer. Also, a green-filtered light source gave higher contrast images comparing to optical images under standard white light. Furthermore, it was found that a image channel separation technique can be an alternative to simply identify the morphological information of graphene oxide, where red, green, and blue color values are separated at each pixels of the optical image. The approaches performed in this study can be helpful to set up a simple and easy protocol for the morphological identification of graphene oxide using a conventional optical microscope instead of a scanning electron microscopy or an atomic force microscopy.

A Study on Improving the Efficiency of Facility Safety Inspection Work Using Images (영상을 활용한 시설물 안전점검 작업 효율성 향상 방안 연구)

  • Jeon, Kyungsik;Kim, Jintae;Lee, Byoungkil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.3
    • /
    • pp.179-186
    • /
    • 2021
  • In general, the daily safety inspection activities, which investigate damages in structures and measures the size of the damage, have been relied heavily on the visual inspection so far. Since the probe of the condition and performance of facilities by such personnel is often dependent on the subjective judgment of the investigator, the consistency and repeatability of the probing results may reduce. Particularly, damage located in a difficult-to-reach place depends mainly on experience with the naked eye, and an unsafe method using a ladder has mainly applied when necessary. Therefore, in this study, we tried to propose a way of using images that can reduce the deviation between safety inspection investigators, enhance objectivity, and improve the safety of workers. In this study, we have applied homographic transformation as a method of correcting the image. As a result of analyzing the size of the damage in the corrected image of the test subject, it confirms that the accuracy of measuring the magnitude of the damage can satisfy the target levels of 5.0mm and 0.005m2, the target accuracy levels. As a result of the field verification test to which the proposed image correction technique applied, the coefficient of variation of the crack length in the structure decreased from 5.4~7.0% to 0.072~0.12%, and that of the damaged area from 10.9% to 1.6%. It confirms that the measurement accuracy is improved. Therefore, it is expected that this study on the image utilization technique in safety inspection activities can increase the accuracy of damage measurement and improve the reliability of the safety inspection reports and exterior survey drawings.

Usability Evaluation of Gel Pad Materials for Superficial Structures used in Musculoskeletal Ultrasonography (근골격계 초음파검사에 사용되는 표재성 검사용 젤 패드 물질의 유용성 평가)

  • Han, Mi-Ran;Kwak, Jong-Gil;Song, Jong-Nam;Jang, Seong-Ju;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.899-909
    • /
    • 2021
  • In Musculoskeletal ultrasound examination, a linear transducer (12-5 MHz) with a contact surface length of 6 cm, which is commonly distributed in medical institutions, does not contact with bent fingers and wrist depressions only by using a conventional liquid ultrasound gel, which causes image loss. In order to solve this image loss, the use of commercially available Water gel pad is increasing. However, it is a disposable medical product. Repeated use is prohibited and expensive. In this study, in order to reduce the economic burden caused by the use of the commercialized Water gel Pad, we searched for water-soluble food thickener powder that can be easily purchased around our lives and manufactured Gel pads. Among them, kappa-Carrageenan Gel Pad, iota-Carrageenan Gel Pad, and Agar-Agar Gel Pad satisfied the evaluation criteria without artifacts in image evaluation using the N-365 Multipurpose Phantom. Also, the price to purchase the food thickener powder was about 38 times cheaper than the existing commercialized Water gel pad. As a result, if you use the food thickener powder such as kappa-Carrageenan, iota-Carrageenan and Agar-Agar to make solidified elastic Gel pad without a cover instead of the commercially available expensive disposable Water gel pad, the convenience and usefulness of use are improved. It is judged that the manufactured Gel pads can contribute well to the role of efficient ultrasound propagation medium.

Geophysical Techniques for Underwater Landslide Monitoring (수중 산사태 모니터링을 위한 지반물리탐사기술)

  • Truong, Q. Hung;Lee, Chang-Ho;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.5-16
    • /
    • 2007
  • The monitoring and investigation of underwater landslide help to understand its mechanism, increase the usefuless of design and construction and reduce the losses. This paper presents three high resolution geophysical techniques electrical resisitance, ultrasonic wave reflection imaging, and shear wave tomography conducted to determine the lab-scaled submerged landslide. Electrical resistance profiles of a soil mass obtained by an electrical resistance probe provide detailed information to assess the spatial distribution of the soil mass with milimetric resolution. An ultrasonic wave image obtained by recording the reflections from interfaces of different impedance materials permits detecting layers and landslide with submilimetric resolution. The pixel based image of immersed landslides is created by the inversion of the boundary information achieved from the traveling time of shear waves. The experimental results show that the ultrasonic wave imaging and the electrical resistance can provide complementary information; and their association with S-wave tomography image can produce a 3-D view of the underwater landslide. This study suggests that geophysical techniques may be effective tools for the detection of the underwater landslides and spatial distribution offshore.

A Prostate Segmentation of TRUS Image using Average Shape Model and SIFT Features (평균 형상 모델과 SIFT 특징을 이용한 TRUS 영상의 전립선 분할)

  • Kim, Sang Bok;Seo, Yeong Geon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.1 no.3
    • /
    • pp.187-194
    • /
    • 2012
  • Prostate cancer is one of the most frequent cancers in men and is a major cause of mortality in the most of countries. In many diagnostic and treatment procedures for prostate disease, transrectal ultrasound(TRUS) images are being used because the cost is low. But, accurate detection of prostate boundaries is a challenging and difficult task due to weak prostate boundaries, speckle noises and the short range of gray levels. This paper proposes a method for automatic prostate segmentation in TRUS images using its average shape model and invariant features. This approach consists of 4 steps. First, it detects the probe position and the two straight lines connected to the probe using edge distribution. Next, it acquires 3 prostate patches which are in the middle of average model. The patches will be used to compare the features of prostate and nonprostate. Next, it compares and classifies which blocks are similar to 3 representative patches. Last, the boundaries from prior classification and the rough boundaries from first step are used to determine the segmentation. A number of experiments are conducted to validate this method and results showed that this new approach extracted the prostate boundary with less than 7.78% relative to boundary provided manually by experts.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

The Study on Ultrasound Physical Characteristic and Synthesis of Tissue Mimicking Materials Used New Materials (신소재를 사용한 인체조직모사물질의 합성과 초음파 물리적 특성에 관한 연구)

  • Ma, Sang-Chull;Kim, Hwa-Sun;Ann, Young-Man
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.245-252
    • /
    • 2010
  • This study analyzed speed of sound, impedance, attenuation coefficient in accordance with acoustic characteristic standard of body soft tissue corresponding with Annex DD of IEC standard 60601-2-37(2007) which is about tissue mimicking materials (TMM) synthesized by polyurethane as a main material and new type of n-type scatter materials. This study reached the following conclusion after analyzing and evaluating image characteristic with SONOACE 9900 c PRIME (MEDESON Co.) and brightness, maximum penetration with convex probe (2.5~5.0 MHz). When n-type scatter materials are increasingly synthesised 0~8% with prepolymer as a main material and polyol mixture as a catalyst, 1. The more scatter materials are increased, the more sound speed of TMM becomes closely similar to soft tissue. 2. The more scatter materials are decreased, the more acoustic impedance becomes closely similar to soft tissue. 3. The more scatter materials are increased, the more attenuation coefficient is increased. 4. The more scatter materials are increased, the more average brightness of images is increased, but there is threshold. 5. The maximum penetration becomes closely similar to soft tissue at the 6% TMM as a scatter material.

Flame Propagation Characteristics Through Suspended Combustible Particles in a Full-Scaled Duct (이송 배관 내 분진폭발의 화염전파특성)

  • Han, OuSup
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.572-579
    • /
    • 2009
  • This study is to investigate experimentally the flame structure and propagation mechanism in dust explosions and to provide the fundamental knowledge. Upward propagating laminar dust flames in a vertical duct of 1.8 m height and 0.15 m square cross-section are observed and flame front is visualized using by a high-speed video camera. Also, the thicknesses of preheated and reaction zone have been determined by a schlieren, electrostatic probe and thermocouple. The thickness of preheated zone in lycopodium dust flame is observed to be 4~13 mm, about several orders of magnitude higher than that of premixed gaseous flames. From the experimental results by a PIV(Particle Image Velocimetry) system, a certain residence time of the unburned particle in preheated zone is needed to generate combustible gas from the particle. The residence time will depend on preheated zone thickness, particle velocity and flame propagation velocity.

Morphologic Analysis of Water-Cooled Bipolar Radiofrequency lesions on Egg White in Vitro

  • Kang, Sang-Soo;Park, Jung-Chan;Yoon, Young-Jun;Shin, Keun-Man
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.151-154
    • /
    • 2012
  • Background: The aim of this study was to document the optimal spacing of two cannulae to form continuous strip lesions and maximal surface area by using water-cooled bipolar radiofrequency technology. Methods: Two water-cooled needle probes (15 cm length, 18-gauge probe with 6 mm electrode tip) were placed in a parallel position 10, 20, 24, 26, and 28 mm apart and submerged in egg white. Temperatures of the probes were raised from $35^{\circ}C$ to $90^{\circ}C$ and the progress of lesion formation was photographed every 1 minute with the increase of the tip temperature. Approximately 30 photographs were taken. The resultant surface areas of the lesions were measured with the digital image program. Results: Continuous strip lesions were formed when the cannulae were spaced 24 mm or less apart; monopolar lesions around each cannula resulted if they were spaced more than 26 mm apart. Maximal surface areas through the formation of continuous strip lesion were 221 $mm^2$, 375 $mm^2$, and 476 $mm^2$ in 10, 20, and 24 mm, respectively. Summations of maximal surface area of each monopolar lesions were 394 $mm^2$ and 103 $mm^2$ in 26 and 28 mm, respectively. Conclusions: Water-cooled bipolar Radiofrequency technology creates continuous "strip" lesions proportional in size to the distance between the probes till the distance between cannulae is 24 mm or less. Spacing the cannulae 24 mm apart and treating about $80^{\circ}C$ for 24 minutes maximizes the surface area of the lesion.