A Test on Quality Improvement of Printed Circuit Board Using Mold Compensation (금형보정을 이용한 PCB 품질향상에 관한 실험)

  • 전영호;권이장
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.1
    • /
    • pp.135-141
    • /
    • 1997
  • The Copper-Clad Laminate (CCL) is a main electronic component of specialtype printed circuit boards (PCBs) such as Silver Through Hole PCB. This CCL should have high reliability under the aging test, and usually the test is done at a higher temperature (110-$150^{\circ}C$) than the normal. Then, this test condition of high temperature may cause such quality problems as hole eccentricity and reduction of distance between part holes. After measuring the CCL shrinkage affected by temperature, the correction factor of a press mold was a, pp.ied to solve these problems. The results showed that the tolerance of hole pitch(${\pm}$$100{\mu}m$) was satisfactory and the internal and external failure costs were reduced by 55%.

  • PDF

A Study for Removing of the Solder from Printed Circuit Boards(PCBs) (인쇄회로기판으로부터 땜납 제거방법에 관한 연구)

  • 이화조;이성규
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.76-85
    • /
    • 2003
  • In this paper, a technical method for removing the solder from PCBs has been proposed to simplify the pulverizing process and to get higher quality of materials for recycling of the electronic parts in the Printed Circuit Boards (PCBs). There are several techniques to remove the solder from PCB, such as physical and chemical method, vibration, suction and blowing and so on. Among them, the suction technique turned out the best method by investigation. In the suction method, there are three variables for removing the solder. They are a temperature of the thermal wire, a velocity of moving PCB and a gap between PCB and thermal wire. To find the optimal variables for the system, an experiment has been conducted by a trial and error method. The optimal variables were found $220^{\circ}C$ of temperature, 11.58mm/s of velocity, 10mm of gap (A gap between suction hole and bottom of PCBs is 5mm). The result of the experiment shows that 50% of the solder were removed.

Optimization Problems for improving Productivity in Printed Circuit Board Manufacturing (PCB 생산에서 생산성 향상을 위한 최적화 문제들)

  • 임석철;김내헌;김형석
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.16 no.28
    • /
    • pp.1-8
    • /
    • 1993
  • Electrical or electronic products have been becoming smaller and high integrated recently, with printed circuit boards(PCB's) being the key components for these products. The introduction of new technology of surface mounted devices(SMD) opens new ways towards high integration on the PCB. Many plants in eletronical industry which produce high variety of PCB's to meet the demands of customer orders require flexibility in PCB's production lines. This survey paper describes the related optimization problems and solution methods to the automated surface mount technology(SMT) assembly lines, and provides with the research direction for improving flexibility.

  • PDF

Development of FPC Vision Aligning Mounter with Two Picker Heads (2개의 헤드를 갖는 FPC 비전 정렬 장착기의 개발)

  • Shin Dong-Won
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.390-393
    • /
    • 2005
  • he FPCs(Flexible Printed Circuit) are currently used in several electronic products like digital cameras, cellular phones because of flexible material characteristics. Because the FPC is usually small size and flexible, only one FPC should not enter chip mounting process, instead, several FPCs is placed on the large rigid pallette and go to the chip mounting process. Currently the job of mounting FPC on the pallette is carried by totally manual way. Thus, the goals of the research is develop the automatic machine of FPC mounting on pallette using vision alignment. The procedure of operating machine is firstly to measure alignment error of FPC, correct alignment errors, and finally mount well-aligned FPC on the pallette. The vision technology is used to measure alignment error accurately, and precision motion control is used in correcting errors nd mounting FPC. The two picker heads handling two FPC together is used to increase the productivity.

  • PDF

Natural Cconvection in a Vertical Channel with Thermal Blocks (장방형 발열체가 부착된 채널에서 자연대류 연구)

  • 최용문;박경암
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.2
    • /
    • pp.438-444
    • /
    • 1993
  • The circuit board of an electronic equipment were simulated with a vertical channel which had thermal blocks protruded from one of the channel walls. A rought front plate was made of a circuit board attached with short wires to simulate the back side of a printed circuit board. Natural convection experiments were carried out to study the effects of channel space and rough front plate and to find the suitable characteristic value after the fourth row. The effect of a rough front plate was negligble. There were negligible effects of the channel space on the first and second heaters. Heat transfer coefficients after the third row decreased as the channel space decreased. Heat transfer coefficients were almost constant for larger than 20 mm channel space. A characteristic length was suggested to non-dimensionalize Nu and Ra numbers in a vertical channel with protruded heaters. A correlation was obtained using the new characteristic lengths.

KSLV-I 하이드라진 추력기 제어기의 진동 해석 및 검증 시험

  • Kim, Ji-Hun;Jung, Ho-Lak;Jeon, Sang-Woon;Choi, Hyung-Don
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.203-208
    • /
    • 2005
  • Electronic components for space launch vehicles are exposed to a severe vibrational environment at launch and flight. The structural reliability of each component can be verified using mathematical approaches. In order to verify the structural reliability, an important parameter is the natural frequency of PCB(Printed Circuit Board) assembly mounted electronic components on and housing mounted PCB assembly in. In this paper, in order to find natural frequencies of PCB assemblies and the housing of hydrazine TCU(Thruster Control Unit), FEM(Finite Element Method) is adapted. The analytical result of FEM is verified by experimental method.

  • PDF

A Numerical Study on the Effect of PCB Structure Variation on the Electronic Equipment Cooling (PCB 구조변화가 전자장비 냉각에 미치는 영향에 관한 수치적 연구)

  • ;;Park, Kyoung-Woo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.12
    • /
    • pp.3329-3343
    • /
    • 1995
  • The interaction of mixed convection and surface radiation in a printed circuit board(PCB) is investigated numerically. The electronic equipment is modeled by a two-dimensional channel with three hot blocks. In order to calculate the turbulent flow characteristics, the low Reynolds number k-.epsilon. model which is proposed by Launder and Sharma is applied. The S-4 approximation is used to solve the radiative transfer equation. The effects of the Reynolds number and geometric configuration variation of PCB on the flow and heat transfer characteristics are analyzed. As the results of this study, it is found that the thermal boundary layer occured at adiabatic wall in case with thermal radiation included, and the effect of radiation is also found to be insignificant for high Reynolds numbers. It is found, as well, that the heat transfer increases as the Reynolds number and block space increase and the channel height decreases and the heat transfer of vertical channel is greater than that of horizontal channel.

Development of the Insufflator for Endoscopic Surgery using the Fluidic System in Printed Circuit Board (유공압 부품이 내장된 인쇄회로기판을 활용한 내시경 수술용 기복기의 개발)

  • Lee, Hee-Nam;Kim, In-Young;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.32-36
    • /
    • 2011
  • The insufflators in endoscopic surgery supply carbon dioxide to make the air-filled cavity in the abdomen. It contains many kinds of pneumatic and electronic parts and they are connected with the air tubes and electrical wires. The printed circuit boards (PCB) perform wiring, holding and cooling tasks in electronic systems. In this study, the PCB is used as the air channel for insufflators to decrease the cost, volume, and the malfunction according to aging of the device. Three layers of PCB made of FR4 are combined with prepreg as adhesive which has the internal airway channel according to the design. By mounting the pressure sensors and valves, the PCB based fluidic system is implemented. After calibration of flow sensor, the flow rate of the gas also can be measured. The climate test, temperature test, and biocompatibility test showed this idea can be used in insufflators for laparoscopic surgery.

A MICRO FLUXGATE SENSOR IN PRINTED CIRCUIT BOARD (PCB) (인쇄회로 기판에 내장된 마이크로 플럭스게이트 센서)

  • 최원열;황준식;나경원;강명삼;최상언
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.151-155
    • /
    • 2002
  • This paper presents a micro fluxgate magnetic sensor in printed circuit board (PCB). The fluxgate sensor consists of five PCB stack layers including one layer magnetic core and four layers of excitation and pick-up coils. The center layer as a magnetic core is made of a micro patterned amorphous magnetic ribbon with extremely high DC permeability of ∼100,000 and the core has a rectangular-ring shape. The amorphous magnetic core is easily saturated due to the low coercive field and closed magnetic path for the excitation field. Four outer layers as an excitation and pick-up coils have a planar solenoid structure. The chip size of the fabricated sensing element is 7.3${\times}$5.7m㎡. Excellent linear response over the range of -100${\mu}$T to +100${\mu}$T is obtained with 540V/T sensitivity at excitation square wave of 3V$\_$P-P/ and 360kHz. The very low power consumption of ∼8mW was measured. This magnetic sensing element which measures the lower fields than 50${\mu}$T, is very useful for various applications such as: portable navigation systems, military research, medical research, and space research.

  • PDF