• 제목/요약/키워드: primary cooling system

검색결과 100건 처리시간 0.025초

SAFETY ANALYSIS OF INCREASE IN HEAT REMOVAL FROM REACTOR COOLANT SYSTEM WITH INADVERTENT OPERATION OF PASSIVE RESIDUAL HEAT REMOVAL AT NO-LOAD CONDITIONS

  • SHAO, GE;CAO, XUEWU
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.434-442
    • /
    • 2015
  • The advanced passive pressurized water reactor (PWR) is being constructed in China and the passive residual heat removal (PRHR) system was designed to remove the decay heat. During accident scenarios with increase of heat removal from the primary coolant system, the actuation of the PRHR will enhance the cooldown of the primary coolant system. There is a risk of power excursion during the cooldown of the primary coolant system. Therefore, it is necessary to analyze the thermal hydraulic behavior of the reactor coolant system (RCS) at this condition. The advanced passive PWR model, including major components in the RCS, is built by SCDAP/RELAP5 code. The thermal hydraulic behavior of the core is studied for two typical accident sequences with PRHR actuation to investigate the core cooling capability with conservative assumptions, a main steam line break (MSLB) event and inadvertent opening of a steam generator (SG) safety valve event. The results show that the core is ultimately shut down by the boric acid solution delivered by Core Makeup Tank (CMT) injections. The effects of CMT boric acid concentration and the activation delay time on accident consequences are analyzed for MSLB, which shows that there is no consequential damage to the fuel or reactor coolant system in the selected conditions.

비상노심냉각계통 주입에 따른 저온관 및 강수관에서 단상 열성층 수치해석 : 부력항 고려 필요성에 관한 연구 (Numerical Analysis of Single Phase Thermal Stratification in both Cold Legs and Downcomer by Emergency Core Cooling System Injection : A Study on the Necessity to Consider Buoyancy Force Term)

  • 이공희;정애주
    • 설비공학논문집
    • /
    • 제29권12호
    • /
    • pp.654-662
    • /
    • 2017
  • When emergency core cooling system (ECCS) is operated during loss of coolant accident (LOCA) in a pressurized water reactor (PWR), pressurized thermal shock (PTS) phenomenon can occur as cooling water is injected into a cold leg, mixed with hot primary coolant, and then entrained into a reactor vessel. Insufficient flow mixing may cause temperature stratification and steam condensation. In addition, flow vibration may cause thermal stresses in surrounding structures. This will reduce the life of the reactor vessel. Due to the importance of PTS phenomenon, in this study, calculation was performed for Test 1 among six types of OECD/NEA ROSA tests with ANSYS CFX R.17. Predicted results were then compared to measured data. Additionally, because temperature difference between the hot coolant at the inlet of the cold leg and the cold cooling water at the inlet of the ECCS injection line is 200 K or more, buoyancy force due to density difference might have significant effect on thermal-hydraulic characteristics of flow. Therefore, in this study, the necessity to include buoyancy force term in governing equations for accurate prediction of single phase thermal stratification in both cold legs and downcomer by ECCS injection was numerically studied.

전력변환장치 캐비넷에서의 내부발열 개선을 위한 열유동 분석 및 유통안전성 향상을 위한 진동특성 분석 (Theoretical Heat Flow Analysis and Vibration Characteristics During Transportation of PCS(Power Conversion System) for Reliability)

  • 주민정;서상욱;오재영;정현모;박종민
    • 한국포장학회지
    • /
    • 제28권2호
    • /
    • pp.143-149
    • /
    • 2022
  • PCS needs to freely switch AC and DC to connect the battery, external AC loads and renewable energy in both directions for energy efficiency. Whenever converting happens, power loss inevitably occurs. Minimization of the power loss to save electricity and convert it for usage is a very critical function in PCS. PCS plays an important role in the ESS(Energy Storage System) but the importance of stabilizing semiconductors on PCB(Printed Circuit Board) should be empathized with a risk of failure such as a fire explosion. In this study, the temperature variation inside PCS was reviewed by cooling fan on top of PCS, and the vibration characteristics of PCS were analyzed during truck transportation for reliability of the product. In most cases, a cooling fan is mounted to control the inner temperature at the upper part of the PCS and components generating the heat placed on the internal aluminum cooling plate to apply the primary cooling and the secondary cooling system with inlet fans for the external air. Results of CFD showed slightly lack of circulating capacity but simulated temperatures were durable for components. The resonance points of PCS were various due to the complexity of components. Although they were less than 40 Hz which mostly occurs breakage, it was analyzed that the vibration displacement in the resonance frequency band was very insufficient. As a result of random-vibration simulation, the lower part was analyzed as the stress-concentrated point but no breakage was shown. The steel sheet could be stable for now, but for long-term domestic transportation, structural coupling may occur due to accumulation of fatigue strength. After the test completed, output voltage of the product had lost so that extra packaging such as bubble wrap should be considered.

주기적안전성평가를 위한 원전 열교환기 Fouling 평가 (Fouling Analyses of Heat Exchangers for PSR)

  • 황경모;진태은;한상길;김병섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1467-1472
    • /
    • 2003
  • Fouling of heat exchangers is generated by water-borne deposits, commonly known as foulants including particulate matter from the air, migrated corrosion produces; silt, clays, and sand suspended in water; organic contaminants; and boron based deposits in plants. This fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. This paper focuses on fouling analyses for six heat exchangers of two primary systems in two nuclear power plants; the regenerative heat exchangers of the chemical and volume control system and the component cooling water heat exchangers of the component cooling water system. To analyze the fouling for heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. Based on the results of the fouling analyses, the present thermal performances and fouling levels for the six heat exchangers were predicted.

  • PDF

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

탄화수소 항공유의 흡열반응 성능향상을 위한 촉매 분해 및 수증기 개질 기술분석 (Analysis of Catalytic Cracking and Steam Reforming Technologies for Improving Endothermic Reaction Performance of Hydrocarbon Aviation Fuels)

  • 이형주
    • 한국추진공학회지
    • /
    • 제25권2호
    • /
    • pp.98-109
    • /
    • 2021
  • 극초음속 비행체용 능동냉각시스템의 전체적인 운용 성능을 결정하는 주요 요소는 크게 탄화수소흡열연료, 재생냉각 채널, 시스템 소재 및 구조로 구분되며, 그 중에서도 효율적인 재생냉각시스템 개발을 위한 일련의 연구는 탄화수소 항공유의 흡열반응 성능 향상으로부터 시작된다. 따라서 이전 연구에서는 탄화수소 항공유 자체의 흡열분해 특성에 대한 광범위한 연구 동향을 정리하였으며, 본 연구에서는 그에 대한 후속 연구로서 효과적인 흡열분해 특성 개선 및 성능 향상 방안으로 다양하게 시도되고 있는 촉매 분해와 수증기 개질 연구들에 대한 세부기술 분석을 수행하였다.

연구용 원자로 냉각계통의 ASME 스트레이너 설계 및 성능시험 (Design and Test of ASME Strainer for Coolant System of Research Reactor)

  • 박용철;박종호
    • 한국유체기계학회 논문집
    • /
    • 제2권3호
    • /
    • pp.24-29
    • /
    • 1999
  • The ASME strainers have been newly installed at the suction side of each reactor coolant pump to get rid of the foreign materials which may damage the pump impeller or interfere with the coolant path of fuel flow tube or primary plate type heat exchanger. The strainer was designed in accordance with ASME SEC. III, DIV. 1, Class 3 and the structural integrity was verified by seismic analysis. The screen was designed in accordance with the effective void area from the result of flow analysis for T-type strainer. After installation of the strainer, it was confirmed through the field test that the flow characteristics of primary cooling system were not adversely affected. The pressure loss coefficient was calculated by Darcy equation using the pressure difference through each strainer and the flow rate measured during the strainer performance test. And these are useful data to predict flow variations by the pressure difference.

  • PDF

강관 토목구조물이 설치된 지열 히트펌프 시스템의 냉방 성능 평가 (Evaluation on Cooling Performance of Ground Source Heat Pump System Equipped with Steel-pipe Civil Structures)

  • 이석재;양정훈;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권3호
    • /
    • pp.14-22
    • /
    • 2023
  • Steel-pipe civil structures, including steel-pipe energy piles and cast-in-place piles (CIPs), utilize steel pipes as their primary reinforcements. These steel pipes facilitate the circulation of a working fluid through their annular crosssection, enabling heat exchange with the surrounding ground formation. In this study, the cooling performance of a ground source heat pump (GSHP) system that incorporated steel-pipe civil structures was investigated to assess their applicability. First of all, the thermal performance test was conducted with steel-pipe CIPs to evaluate the average heat exchange amount. Subsequently, a GSHP system was designed and implemented within an office container, considering the various types of steel-pipe civil structures. During the performance evaluation tests, parameters such as the coefficient of performance (COP) and entering water temperature (EWT) were closely monitored. The outcomes indicated an average COP of 3.74 for the GSHP system and the EWT remained relatively stable throughout the tests. Consequently, the GSPH system demonstrated its capability to consistently provide a sufficient heat source, even during periods of high cooling thermal demand, by utilzing the steel-pipe civil structures.

Coolant Options and Critical Heat Flux Issues in Fusion Reactor Divertor Design

  • Baek, Won-Pil;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • 제29권4호
    • /
    • pp.348-359
    • /
    • 1997
  • This paper reviews cooling aspects of the diverter system in Tokamak fusion devices with primary emphasis on the critical heat flux (CHF) issues for oater-cooled designs. General characteristics of four (4) coolant options for diverter cooling gases, oater, liquid metal, and organic liquid - are discussed first, focusing on the comparison of advantages and disadvantages of those options. Then results of recent studies on the high-heat-flux CHF of water at subcooled high-velocity conditions are reviewed to provide a general idea on the feasibility of the water-cooled diverter concept for future Tokamak fusion reactors. Water is assessed to be the most viable and practical coolant option for diverters of future experimental Tokamaks.

  • PDF

차세대 원자로 정지냉각계통의 냉각 성능에 대한 연구 (A Study of Cooldown Performance of Shutdown Cooling System of Korea Next Generation Reactor)

  • 유성연;이상섭
    • 에너지공학
    • /
    • 제8권4호
    • /
    • pp.525-532
    • /
    • 1999
  • 한국형 차세대 원자로는 ABB-CE사의 System 80+의 설계개념을 근간으로 하여 표준화된 원자로의 계통설계를 추진하고 있다. 본 연구에서는 차세대 원자로 정지냉각계통의 운전시 요구되는 인허가 요건등제반 조건을 충족시킬 수 있는지를 해석하였다. 또한 운전시 필요한 열교환기의 유효면적과 원자로 기기냉각수 유량등 기본적인 설계자료를 산출하여 차후 차세대 원자로 정지냉각계통의 상세설계 업부를 수행하는데 필요한 기초자료를 제시하여 핵증기공급계통 (NSSS)의 기술개발을 이루는데 목적이있다. 차세대 원자로는 울진 3, 4호기 열출력 2.825MWth 에 비해 열출력이 4,000MWth 로 증가되어 정지냉각계통의 관련서례자료를 새로 산출해야하므로 정지냉각계통의 냉각능력을 평가하는 KDESCENT 전산코드를 이용하여 원자로 노심의 잔열과 정지냉각계통의 현열을 제거할 수 있는 최소 유량을 제시하였으며 주요 구성기기인 열교환기, 펌프, 밸브 및 기타 기기의 기능 및 정지냉각계통의 운전절차를 고찰하였다.

  • PDF