Development of a Time-selective Self-triggering Water Sampler and Its Application to In-situ Calibration of a Turbidity Sensor

  • Jin, Jae-Youll;Hwang, Keun-Choon;Park, Jin-Soon;Yum, Ki-Dai;Oh, Jae-Kyung
    • Journal of the korean society of oceanography
    • /
    • 제34권4호
    • /
    • pp.200-206
    • /
    • 1999
  • Seawater sampling is the primary task for the study of the marine environmental parameters that require shipboard or laboratory experiments for their analyses, and is also required for the calibration of some instruments for in situ measurement. A new automatic bottle (AUTTLE) is developed for seawater sampling at any desired time and water depth by self-triggering. Both any type of single or assembled mooring for 15 days and manual actuation by using a remote messenger as existing instantaneous single point water samplers are possible. Its sampling capacity and the resolution of time setting are 2 liters and 1 second, respectively. The result of a field experiment with an optical backscattering sensor (OBS) and a total of 14 AUTTLES for the in situ calibration of the OBS shows that the AUTTLE must improve our understanding on the behavior of the sand/mud mixtures in the environments with high waves and strong tides. The AUTTLE will serve as a valuable instrument in the various fields of oceanography, especially where synchronized seawater sampling at several sites is required and/or the information in storm period is important.

  • PDF

Identification and Correction of Microlens-array Error in an Integral-imaging-microscopy System

  • Imtiaz, Shariar Md;Kwon, Ki-Chul;Alam, Md. Shahinur;Hossain, Md. Biddut;Changsup, Nam;Kim, Nam
    • Current Optics and Photonics
    • /
    • 제5권5호
    • /
    • pp.524-531
    • /
    • 2021
  • In an integral-imaging microscopy (IIM) system, a microlens array (MLA) is the primary optical element; however, surface errors impede the resolution of a raw image's details. Calibration is a major concern with regard to incorrect projection of the light rays. A ray-tracing-based calibration method for an IIM camera is proposed, to address four errors: MLA decentering, rotational, translational, and subimage-scaling errors. All of these parameters are evaluated using the reference image obtained from the ray-traced white image. The areas and center points of the microlens are estimated using an "8-connected" and a "center-of-gravity" method respectively. The proposed approach significantly improves the rectified-image quality and nonlinear image brightness for an IIM system. Numerical and optical experiments on multiple real objects demonstrate the robustness and effectiveness of our proposed method, which achieves on average a 35% improvement in brightness for an IIM raw image.

Absolute calibration of near-infrared Period-Luminosity-Metallicity relations for RR Lyrae variables using Gaia EDR3

  • Bhardwaj, Anupam;Rejkuba, Marina;Yang, Soung-Chul
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.35.1-35.1
    • /
    • 2021
  • RR Lyrae stars are sensitive probe for the precision stellar astrophysics and also for the cosmic distance scale thanks to their well-defined near-infrared Period-Luminosity relations (PLRs). These horizontal branch variables can be used for primary calibration of the first-rung of population II distance ladder providing an evaluation of the ongoing tension between Cepheid-Supernovae based Hubble constant and the Planck results. Therefore, absolute calibration of RR Lyrae PLRs is now crucial to complement or test the tip of the red giant branch based distances, and in turn, population II star based Hubble constant measurements. While the pulsation models of RR Lyrae can reproduce most observables, they predict a significant metallicity effect on their JHKs-band PLRs that is inconsistent with so-far limited observational studies. We remedy this inconsistency of metallicity dependence in RR Lyrae PLRs by combining their near-infrared observations in the globular clusters of different mean-metallicities with the new parallaxes from the Gaia early data release 3 (EDR3). Our empirical results on Period-Luminosity-Metallicity (PLZ)relations are consistent with theoretical predictions but the precision of absolute calibrations is still affected by the parallax uncertainties and the systematic zero-point offset present in the Gaia EDR3.

  • PDF

Uncertainty Analysis in Potential Transformer Calibration Using a High Voltage Capacitance Bridge

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Kwon, Sung-Won;Kim, Myung-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.401-407
    • /
    • 2007
  • Precise absolute measurement of the errors in a potential transformer (PT) can be achieved using high voltage capacitance bridge (HVCB) and capacitive divider. The uncertainty in a PT measurement using the HVCB system was evaluated by considering the overall factors affecting during the calibration of a PT. The expanded uncertainties are found to be not more than $30{\times}10^{-6}$ for ratio and $30{\mu}rad$ for phase up to the primary voltage of $V_p=22kV$. For same PTs, the measured errors in KRISS (Korea Research Institute of Standards and Science) using our bridge are well coincide with those in NMIA (National Measurement Institute of Australia) and PTB (Physikalisch-Technische Bundesanstalt) within the corresponding uncertainties.

EVALUATION OF THE RADIOMETRIC AND SPECTRAL CHARACTERISTICS OF THE CAISS

  • Lee, Kwang-Jae;Yong, Sang-Soon;Kim, Yong-Seung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.243-246
    • /
    • 2008
  • The Compact Airborne Imaging Spectrometer System (CAISS) was jointly designed and developed as the hyperspectral imaging system by Korea Aerospace Research Institute (KARI) and ELOP inc., Israel. The primary mission of the CAISS is to acquire and provide full contiguous spectral information with high quality spectral and high spatial resolution for advanced applications in the field of remote sensing. The CAISS consists of six physical units; the camera system, the gyro-stabilized mount, the jig, the GPS/INS, the power inverter and distributor, and the operating system. These subsystems shall be tested and verified in the laboratory before the flight. Especially the camera system of the CAISS shall be calibrated and validated with the calibration equipments such as the integrated sphere and spectral lamps. To improve data quality and availability, it is the most important to understand the mechanism of hyperspectral imaging system and the radiometric and spectral characteristics. This paper presents the major characteristics of camera system on the CAISS and summarizes the results of radiometric and spectral experiment during preliminary system verification.

  • PDF

Intercomparison of KAERI Reference Photon Radiation Fields

  • S.Y.Chang;J.C.MacDonald;M.K.Murphy;Kim, B.H.;Lee, K.C.
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(4)
    • /
    • pp.34-39
    • /
    • 1996
  • A series of measurements was peformed between KAERI and PNNL, U.S.A at KAERI secondary calibration laboratory to intercompare and verify the KAERI reference photon radiation fields by using air equivalent plastic walled ionization chambers, Different ionization chambers of two laboratories were used to determine the air kerma rate, free-in-air, at reference positions in the KAERI photon radiation fields, As the results, the agreement in the cross measurements between two laboratories was found to be within less than ${\pm}$ 3 %. This degree of consistency was considered to be encouraging, because each laboratory maintains independently its calibration traceablity with its national primary standard

  • PDF

판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 - (Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period)

  • 이원홍;손순룡;노성순;이인화;강성호;이용문;박재수;윤석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권1호
    • /
    • pp.55-60
    • /
    • 2008
  • 목적: 판독용 모니터의 성능을 평가하는데 있어 불필요한 시간 및 인력 등을 줄이고 판독의 최적화 유지와 모니터의 upgrade 시기, 그리고 교체 시기를 결정할 수 있는 시스템을 구축하는데 필요한 적절한 수준의, 일정기간의 성능평가 관리 주기 및 calibration 주기를 결정하고자 하였다. 대상 및 방법: 판독용 LCD 컬러 모니터(CCL350i, Totoku, Japan) 20대를 대상으로 2007년 3월부터 8월(첫 calibration 후 3, 4, 5, 6, 7, 8개월째)까지 매달 1회에 걸쳐 한 달 주기로 총 6회의 성능 평가를 하였다. 성능 평가에 사용된 측정 도구는 휘도계(DTP 94 39630, X-Rite Inc. U.S.A.)와 조도계(LX-101 Q031871, Lutron, U.S.A.) 그리고 모니터 성능관리 프로그램인 AAPM TG 18 protocol를 이용하였다. 성능평가 항목은 기하학적 왜곡(geometric distortion), 반사 테스트(reflection test), 휘도 반응 평가(luminance response evaluation), 휘도 균일도(luminance uniformity), 분해능(resolution), 노이즈(noise), 베이링 그레어(veiling glare), 색도(chromaticity) 등 8개 항목을 포함하였다. 결과: 기하학적 왜곡 평가와 반사 테스트, 휘도 균일도 테스트, 분해능, 노이즈 평가, 베이링 그레어 테스트, 색도 테스트 등은 AAPM TG 18에서 권고하는 기준치에 모두 부합되었다. 휘도반응평가 중 예측되는 최대 휘도와 관측되는 휘도의 편차 항목에서 4개월째부터 25%(4대)의 모니터가 8개월째까지 기준 편차를 벗어나기 시작하였으며, 8개월째에는 다른 모니터 7대에서도 편차를 보이기 시작하여 전체적으로 55%(11대)의 모니터에서 기준 편차를 벗어나고 있었다. 또한 대조도 반응의 편차 항목에서 4개월째부터 예측되는 최대 휘도와 관측되는 휘도의 편차의 기준치를 벗어나기 시작한 4대의 모니터 중 5%(1대)에서 4개월째부터 8개월째까지, 또다른 2대는 8개월째부터 편차를 보여 전체적으로 8개월째에는 15%(3대)의 모니터에서 기준 편차를 벗어났다. 결론: 성능평가의 주기는 calibration 후 4개월째부터 오차 범위를 벗어나는 결과와 모니터 수 그리고 성능 검사에 소요되는 인력 및 시간을 고려할 때 3개월에 한번씩 평가함이 효율적이라고 판단된다. 또한 calibration 주기는 8개월째부터 50% 이상에서 편차를 보인 결과 및 성능평가 주기를 고려할 때 calibration 후 6개월을 주기로 calibration을 다시 시행하여야 할 것으로 판단된다.

  • PDF

2차원 시분해 레이저 유도 백열법을 이용한 에틸렌 확산 화염에서의 매연 입자 크기 측정 (Soot Primary Particle Size Measurement in a Ethylene Diffusion Flame Using Time-Resolved Laser-Induced Incandescence)

  • 손무강;문건필;김규보;이종호;정동수;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1140-1145
    • /
    • 2004
  • Laser-induced incandescence (LII) is introduced as a valuable tool for the characterization of nanoparticles in flame environments. This technique is based on the heating of the particles by a short laser pulse and the subsequent detection of the thermal radiation. It has been applied successfully for the investigation of soot in different fields of application. The evaluation of the temporal decay of the laser-induced incandescence (LII) signal from soot particles is introduced as a technique to obtain two-dimensional distributions of particle sizes and is applied to a laminar diffusion flame. This novel approach to soot sizing exhibits several theoretical and technical advantages compared with the established combination of elastic scattering and LII, especially as it yields absolute sizes of primary particles without requiring calibration. With this technique a spatially resolved 2-D measurement of soot primary particle sizes is feasible in a combination process form the ratio of emission signals obtained at two delay times after a laser pulse, as the cooling behavior is characteristic of particle size.

  • PDF

물흡수선량 표준에 기반한 $^{192}Ir$ 근접치료 선원 교정 시 원통형 이온함의 이온함 간 변화 (Chamber to Chamber Variations of a Cylindrical Ionization Chamber for the Calibration of an $^{192}Ir$ Brachytherapy Source Based on an Absorbed Dose to Water Standards)

  • 김성훈;허현도;최상현;김찬형;민철희;신동오;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.7-13
    • /
    • 2009
  • 본 논문은 물 흡수선량 표준에 기반하여 근접치료 선원인 $^{192}Ir$을 교정하는 것에 대한 예비적 연구를 위한 것이다. 이온함을 사용하여 물흡수선량 표준에 기반하여 근접치료 선원을 교정하기 위해선, 빔 선질 교정인자인 $k_{Q,Q_0}$가 필요하다. 본 연구에선 일차 표준을 사용하여 지정된 거리에서의 흡수선량를 측정하는 데 있어서의 현실적인 어려움 때문에 몬테칼로 전산모사와 반실험적인 방법을 통하여 $k_{Q,Q_0}$를 결정하였다. 본 연구를 위해 PTW30013 이온함 5개를 선택하였다. 포괄적 $k^{gen}_{Q,Q_0}$ 값의 경우엔 이온함간 변화가 최대 4.0%에 이른 반면, 개별적 $k^{ind}_{Q,Q_0}$ 경우엔 이온함간 변화가 최대 0.5% 이내였다. 이 결과는 물 흡수선량에 기반하여 근접치료 선원인 $^{192}Ir$을 교정시에 이온함을 왜 개별적으로 교정해야 하는지, 개별적인 교정이 얼마나 중요한 지를 보여 준다. 가까운 장래에 공기커마 세기 대신에 사용자가 근접치료 선원을 고에너지 광자빔과 전자빔의 교정에서처럼 치료에서 관심있는 물리량인 물흡수선량의 관점에서 교정할 수 있기를 희망한다.

  • PDF

위성 데이터에 의한 선박 탐지: RADARSAT의 대기보정과 기하보정 (Ship Detection by Satellite Data: Radiometric and Geometric Calibrations of RADARS AT Data)

  • 양찬수
    • 해양환경안전학회지
    • /
    • 제10권1호
    • /
    • pp.1-7
    • /
    • 2004
  • RADARSAT 위성은 레이더센서를 가지고 있어 전천후 및 주야불문이라는 두 가지 주요 이점을 가지고 있기 때문에, 선박탐지를 포함하는 해상감시 분야에 있어서 중요한 역할을 할 수 있다 그러나, 합성개구레이더의 이미징 시에 대기의 영향은 무시될 수 없으며, 또한 다양한 형태로 기하 변형이 발생하게 된다. 본 연구에서는, 레벨 1의 georeferenced SGX 데이터를 사용해서 RADARSAT의 합성개구레이더에 대한 대기/기하 보정을 실시하였다. 동일 이미지 내에서도, near range와 far range 세션의 비교를 위해서도 이와 같은 보정이 필요하다. 대기 보정은 후방산란에 대한 국소 조사부분과 입사각의 효과를 보정하여 수행되었으며, DN값은 beta nought와 sigma nought로 변환시켰다. 마지막으로 위성자세정보에서 추정되는 4점의 위치정보를 이용하여 자동 기하보정을 실시하였으며, 그 결과를 실제 좌표 값과 비교하였다. 오차는 위도방향으로 300m, 경도방향으로 260m범위 내에 있는 것으로 확인되었다. 이것은 추가로 지상기준점을 통해 보정될 수 있으며, 외해의 경우에는 적용 가능한 것으로 판단된다.

  • PDF