• 제목/요약/키워드: preventing electric fire

검색결과 23건 처리시간 0.021초

Electrical Fire Hazards Analysis of Electric Iron and Heater Using Fault Tree Analysis

  • Hong, Sung-Ho
    • International Journal of Safety
    • /
    • 제7권1호
    • /
    • pp.15-20
    • /
    • 2008
  • The primary goal of this study is to analyze fire hazards of electric home appliances such as electric iron and electric heater using fault tree analysis(FTA). A fault tree(FT) is constructed and used to analyze fire hazards in electric home appliances. The fault tree is built from events that may occur in electric home appliances. The failure rate of basic events are derived from the value of experimental results and reference. And an algorithm analyzing fire in electric home appliances is suggested. We show how fault tree analysis, carried out by means of failure rate, is able to diagnose fire hazards of electric home appliances in a precise manner. We present numerical results such as fire probability of electric home appliances, importance measure, fire cause, etc. It can be helpful in preventing the fire hazards in electric home appliances.

Integrated Safety System based on IoT

  • Shin, Jin Seob
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권10호
    • /
    • pp.159-165
    • /
    • 2019
  • 현재 화재의 58%정도는 전기에 의한 화재이다. 본 연구에서는 전기에 의한 화재의 요인을 분석하여 미연에 화재를 예방이 가능한 시스템에 대하여 연구하였다. 재난재해를 예방하기 위해서는 기본적으로 화재 징후를 알아내기 위한 다양한 전기에 관한 IoT 센서들이 필요하다. 이러한 센서들은 각각 발생하는 많은 상황정보들을 계속적으로 수신하고 메인시스템으로 전송한다. 이렇게 모아진 빅 데이터들은 패턴분석을 통해 재난이 발생할 수 있는 임계치를 벗어나는지 여부를 계속적으로 체크하며 데이터의 비교를 통하여 어느 부분의 문제가 있는지 여부도 체크할 수 있다. 임계치를 벗어나는 상황에는 경보신호를 알려주고 문제 있는 부분에 대한 정보도 전달한다. 이를 통해 과전류, 누설전류 등과 같은 전기적인 문제를 미연에 방지함으로써 화재를 예방할 수 있는 결과를 보여준다.

화재방지제어 시스템 IC (A System IC for Controlling the Fire Prevention)

  • 김병철
    • 한국정보통신학회논문지
    • /
    • 제13권4호
    • /
    • pp.737-746
    • /
    • 2009
  • 본 연구에서는 정보가전기기에서 과부하를 방지하고 이상신호를 검출하며 화재방지를 제어할 수 있는 원 칩(one chip) 시스템 IC를 개발하였다. 이를 위하여 화재에 직접적으로 영향을 미치는 아크(arc) 검출회로와 감전을 방지하기 위한 누전검출회로를 설계하였다. 시뮬레이션과 표준트랜지스터를 이용한 bread boarding 평가에 의해 블록별로 설계된 회로를 검증하였다. 평가결과로부터 34 V 2 Metal $1.5{\mu}m$바이폴라 트랜지스터 공정을 이용하여 시스템 IC를 제작하였다. 제작된 시스템 IC와 IC응용회로를 PCB보드에 실장하여 화재방지 시스템보드의 전기적 성능을 평가하였으며, 아크와 GF(ground fault) 신호에 잘 동작함을 확인하였다.

4M 기법을 활용한 전기화재 예방대책 수립 연구 (A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique)

  • 오택흠;박찬석
    • 대한안전경영과학회지
    • /
    • 제23권4호
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

화재사례를 통한 에어컨의 화재위험성 연구 (Study on Fire Risk of Air Conditioner through Fire Cases)

  • 최승복;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.70-77
    • /
    • 2017
  • 삶의 질이 높아짐에 따라 에어컨의 사용이 증가하고 있다. 따라서 에어컨 사용에 따른 화재 또한 빈번하게 발생하고 있어, 이에 따른 예방대책이 요구된다. 지난 2016년 전국 화재발생은 43,413건 이며, 이중 전기로 인한 화재가 8,655건으로 약 20%를 차지하였다. 전기화재 중 에어컨은 134건으로 약 1.5%를 차지하였고, 불완전접촉, 합선, 트래킹과 같은 다양한 원인으로 발생하는 것으로 나타났다. 본 연구는 에어컨 설치과정에서 실외기에 연결된 전원코드를 임으로 연결하는 접속부위에서 발화한 사례에 대하여 연구하고 그 원인에 따른 예방대책을 제시하여 전기화재로부터 인명과 재산피해를 다소나마 줄이고자 한다.

전기로 인한 화재 원인 통계와 고찰 (A statistics and study of fire cause by electrics)

  • 이영수;김명수;황병표;김형수;송영학
    • 한국화재조사학회지
    • /
    • 제10권1호
    • /
    • pp.47-57
    • /
    • 2007
  • 급격한 경제발전과 더불어 전기로 인한 화재가 발생하면 막대한 인명과 재산피해가 발생하여 국가적으로 크나큰 손실이 아닐 수 없다. 이러한 전기화재를 예방하기 위해서는 원인과 장소별 등으로 분류된 세부적인 통계를 생산하고 정확한 화재원인을 규명하여 화재예방 자료로 활용하는 것이 가장 근본적인 대책이라 할 수 있다. 이 논문에서는 최근 10년간 화재발생 현황 및 2006년 전기화재 원인별, 장소별, 월별로 분석하였고 또한, 2005년 전기화재 8,554건에 대하여 전국의 소방서를 우리공사 직원이 직접 방문하여 심층적이고 전문적인 전기화재 실태조사를 실시하였다. 따라서 이번 논문이 전기화재를 예방하는 자료로 활용되고 정확한 화재통계 생산에 디딤돌이 되었으면 하는 바람으로 제시하였다.

  • PDF

동파방지열선 화재 흔적분석과 발화원인 연구 (A Study for the Fire Analysis and Igniting Cause of Freezing Protection Heating Cables)

  • 이정일;하각천
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.15-20
    • /
    • 2018
  • There have been a number of major fatal fire accidents in Korea recently. The number of fires in 2017 were 44,178, which is not only increasing number of fires but also increasing in casualties. Particularly, the fire at Jecheon Sports Center, which suffered many casualties, is expected to have a huge impact. The cause of the fire has not been determined yet, but heat waves on the ceiling have also been pointed out. As such, the copper heating waves, which are used as a preventive measure against damage of pipes due to freezing of pipes, etc., always have a fire hazard. To determine the possibility of a flame-resistant heated fire, a positive electric cable product was used to artificially ignite and analyze the results. In case of a short circuit, the external covering of the positive electric cable is damaged, but not short circuit unless the heating material surrounding the wire is damaged. Due to the characteristics of heating cable for preventing copper waves, the chances of insulation becoming more severe due to moisture and temperature changes are higher than normal wires. If the internal heating system is carbonized by insulating deterioration without damage to the outer coating, it is likely to cause trekking, to form a winding loop in the heating materials, and to cause short circuit in the heated materials. For the positive temperature line, if the middle is shorted, the current continues to flow to the short circuit unless the breaker disconnects. Consequently, a heated fire that does not cut off the power immediately may leave multiple marks or cuts.

인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석 (The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current)

  • 김재현;임용배;이상익;김동우
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

아크 검출기 관련 규정 마련에 관한 연구 (A study on working out arc detector related regulations)

  • 박용서
    • 디지털융복합연구
    • /
    • 제16권11호
    • /
    • pp.115-122
    • /
    • 2018
  • 국내에서 전기 화재의 70% 이상이 아크로 인하여 발생하고 있다. 본 논문에서는 이를 예방하기 위한 방안을 마련하기 위하여 기존의 누전 차단기에 관한 기술기준 및 규정을 분석하였으며, 아크 검출기에 관한 기술기준 및 규정은 아크의 특성을 고려하여 기존의 누전 차단기에 관한 기술기준 및 규정과는 별도로 제정되어야 한다는 결론을 얻었다. 따라서 본 논문에서는 아크 검출기 관련 규정은 기존 누전 차단기의 관련 규정에 추가 되거나 이것과 별개인 규정으로 제정되어야 한다고 제안하였다. 특히 아크로 인한 화재를 예방하기 위해서는 아크 검출기의 신속한 보급이 필요하고 그 설치를 의무화하는 것이 바람직하다. 따라서 이 같은 여건을 고려했을 때 기존 누전차단기 규정에 아크 검출기 관련 사항들을 추가할 것을 제안하였다. 아크 검출기의 기술 기준에는 아크의 판단 규격과 차단 임계치, 그리고 차단기가 반응하지 말아야 할 불요신호의 범위 등이 반드시 반영되어야 한다.

식료품제조업 전기설비의 전기화재방지를 위한 위험우선순위 분석 (Risk Priority Analysis for Preventing Electrical Fires in Food Manufacturing Electrical Facilities)

  • 이승구;김두현;김성철
    • 한국안전학회지
    • /
    • 제39권1호
    • /
    • pp.16-26
    • /
    • 2024
  • This study aims to introduce a method for risk assessment analysis aimed at preventing electrical fires within the manufacturing industry. Initially, we provided a functional block diagram illustrating the electrical equipment employed in various processes within a food manufacturing company in Chungcheongbuk-do. Subsequently, we categorized the components of each machine outlined in the functional block diagram and determined the priority of failure for each classified component. Upon implementing the model in the frying process of the food manufacturing company, specific components, including MC, motor, mixer heater, electric wiring, and terminal block, exhibit a risk priority number (RPN) of 40 or higher. This identified an electrical issue within the manufacturing process and environment. Consequently, we propose a methodology to identify latent failure modes that could escalate into fires or systemic issues if not promptly addressed. It is essential to note that while the FMEA presented in this study may not immediately impact food manufacturing, its applicability extends to various workplaces.