• 제목/요약/키워드: pretensioned

검색결과 66건 처리시간 0.019초

고강도 프리텐션 프리스트레스트 콘크리트 부재 단부 영역에서의 PS 강연선 부착특성 연구 (Bond Characteristics of PS Strand around the End Zones of High Strength Pretensioned Prestressed Concrete Members)

  • 김동백;김의성
    • 한국안전학회지
    • /
    • 제15권3호
    • /
    • pp.102-107
    • /
    • 2000
  • The extensive use of pretensioned prestressed concrete in the modem construction industry, together with wider application of pretensioned components for structural purposes requires some important consideration on the adequate transfer of prestress force into the concrete, especially around the end zones of pretensioned member. The main objective of this paper is to study the effects of various important parameters on the bond characteristics of prestressing strand around the end zone of high strength pretensioned concrete members. To this end, a comprehensive experimental program has been set up. The principal test variables considered were strand diameter, concrete strength, concrete cover size. The present study provides valuable test data for the realistic and accurate determination of transfer length, which can be efficiently used for improving the design equation of transfer length in pretensioned prestressed concrete members.

  • PDF

Theoretical Determination of Transfer Length in Pretensioned Members Using Thick Cylinder Theory

  • Oh, Byung-Hwan;Kim, Eui-Sung
    • KCI Concrete Journal
    • /
    • 제12권2호
    • /
    • pp.31-43
    • /
    • 2000
  • The extensive usage of pretensioned prestressed concrete component in modem construe- tion as structural members mandates precise understanding of its mechanism. Especially, an adequate transfer of prestressing force from steel tendons to concrete around the end regions of the member is a critical issue. Due to the importance of the topic, several investigators have formulated equations modeling the transfer bond length based on various bonding mechanism between steel and concrete. However, the existing models are still inadequate in predicting the bond development in pretensioned prestressed concrete members. Therefore, this study presents a model of transfer bond length based on rational theory that can simulate experimental results. The model is developed into solid mechanics based structural analysis computer program. The program is validated by comparing the analysis results with experimental results of bond stress distribution, concrete strain profiles, and transfer length in pretensioned prestressed concrete members. The proposed analytical procedure in this study can be utilized as a useful tool for realistic evaluation of transfer length in pretensioned prestressed concrete members.

  • PDF

프리텐션공법의 프리스트레스트 콘크리트 부재의 정착길이 산정에 관한 실험 및 이론연구 (Derivation of Development Length in Pretensioned Prestressed Concrete Members)

  • 오병환;김의성;최영철
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.3-11
    • /
    • 2000
  • In pretensioned concrete structures, bond between prestressing steel and concrete is an essential component to ensure the integrity of a pretensioned member. The anchorage and development of the prestressing force depend exclusively on bond. The purpose of this study is to investigate the characteristics of bond and development length between pretensioned steel and concrete. To resolve the controversy over the adequacy of the current code provision on development length of prestressing strands, a comprehensive test program has been scheduled and twenty four rectangular prestressed concrete beams have been tested to determine development length. Major test variables include diameter of strands (12.7mm, 15.2mm) and concrete covers (3cm, 4cm, 5cm). The test results indicate that the development length based on the bond stress-slip relation. The proposed model can evaluate realistically the development length of pretensioned prestressed concrete members and can be the good basis for the future basis of code equations on development length of PSC members.

프리텐션 부재의 휨부착에 의한 강연선 정착길이 연구 (An Experimental Study on Development Length of Strand in Pretensioned Concrete Members)

  • 오병환;최영철;김의성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.367-370
    • /
    • 1999
  • An experimental study was carried out to estimate development lengths of the prestressing strand in pretensioned beams. Recent studies had indicated that current desing provision were inadequate. Objective of this investigation is to determine the effect of strand diameter and concrete cover in pretensioned beams. Strand of the 1.52cm diameter is more useful and economic than that of the 12.7mm diameter, but current provision does not include 15.2mm diameter strand in experimental data. Because the property of strand has been developed, current provision need to be improved. Based on the experimental data, it was determined that bond failure would be prevented if no cracking occured in transfer zone of a pretensioned strand.

  • PDF

전단벽의 내진보강을 위한 방법에 관한 연구 (Retrofitting Device to Increase Seismic Resistant Capactiy of Shear Walls)

  • 홍성걸;이지형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.25-28
    • /
    • 2005
  • The elastic buckling load or strength of a concentrically loaded slender metal column may be increased many times by reinforcing it with an assemblage of pretensioned stays and rigidity connected crossarm members. The complete system is herein referred to as a 'stayed column'. The purpose of the pretensioned stays and crossarm members is to introduce, at several points along the length of the column, restraint against translation and rotation and thereby decrease the effective unsupported buckling length of the column. This paper verifies that pretensioned cable of stayed column is effective for cyclic load and increases strength of shear wall against earthquake by reinforcing side of wall. Design process of stayed column which satisfies demanded capacity and ductility of wall is presented by analyzing result of experiment.

  • PDF

Analysis of stress distribution in anchorage zones of pretensioned beams

  • Gens, F.;Dotreppe, J.C.
    • Computers and Concrete
    • /
    • 제1권3호
    • /
    • pp.249-260
    • /
    • 2004
  • The stress transmission mechanism in pretensioned concrete beams, though very interesting from an economical point of view, is very complex, integrating various phenomenons such as sliding, bond, bursting. For long the complexity of this mechanism has led engineers to provide a massive rectangular anchorage zone at each end of the beam. The necessity of using such a concrete reinforcement is certainly unquestionable in post-tensioned beams. However in pretensioned elements the stresses induced in concrete in the anchorage zone are smaller than in post-tensioned elements. In this article the stress field in the end zone is calculated numerically and from this analysis the possible reduction of the cross-section of the anchorage block is examined.

프리텐션 PSC부재의 전달길이 해석 및 예측에 관한 연구 (Finite Element Analysis of Transfer Length in Pretensioned Prestressed Concrete Members)

  • 오병환;임시내;최영철
    • 콘크리트학회논문집
    • /
    • 제16권3호
    • /
    • pp.293-302
    • /
    • 2004
  • 국내외의 건설공사에 프리텐션 방식을 이용한 프리스트레스트 콘크리트 구조물이 폭넓게 활용됨에 따라 프리텐션부재 단부에서의 응력전달에 관한 관심이 증가되고 있다. 그러나 전달길이에 대한 현행 기준에서는 프리스트레스 힘의 크기와 PS 강재의 직경만을 고려하고 있으나 프리스트레스를 도입할 때의 콘크리트의 강도 및 피복두께 등의 인자들도 전달길이에 영향을 미치는 것으로 나타나고 있다. 따라서 본 연구에서는 강선의 직경과 유효 프리스트레스의 크기뿐만 아니라 콘크리트의 압축강도와 콘크리트의 피복두께 등이 PSC부재의 전달길이에 미치는 영향을 정량적으로 규명하고, 이로부터 이 영향 인자들을 고려한 합리적인 전달길이 예측식을 제안하였다. 이 식의 제안을 위하여 먼저 강선과 콘크리트 사이의 부착거동에 대한 부착응력-슬립 모델을 실험 자료로부터 도출한 후 이를 계면요소에 도입하여 다양한 설계변수에 대하여 유한요소해석을 실시하여 전달길이를 구하였다. 이로부터 각 변수가 전달길이에 미치는 영향을 분석하고 이를 바탕으로 설계시 사용할 수 있는 전달길이의 예측식을 유도하여 제안하였다. 본 연구에서 제시한 예측식은 보다 실제적이고 정확한 전달길이를 결정하는데 유용하게 사용될 수 있으며 프리텐션 프리스트레스트 콘크리트 부재의 전달길이에 대한 현행 설계기준을 개선하는 데에 유용한 자료를 제공할 것으로 사료된다.

휨과 비틀림을 동시에 받는 PSC 역티형보와 직사각형보의 거동 비교 (Comparison on Flexural and Torsional Behaviors of Inverted Tee and Rectangular Precast Pretensioned Concrete Beams)

  • 설동재;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.190-193
    • /
    • 2003
  • Flexural-torsional behaviors of the typical architectural precast beam sections - inverted tee and rectangular - were compared. The inverted-tee beams were designed with a parking live load - 500kgf/$\textrm{m}^2$ and a market-1,200kgf/$\textrm{m}^2$ according to the currently used typical shape in the domestic market building site. The rectangular beams were also designed as the same bottom dimension and area, and reinforced for similar strength as in the cases of inverted tee beams. Two rectangular and two inverted precast pretensioned concrete beams were tested and analyzed

  • PDF

80MPa급 고강도 프리텐션 거더의 휨성능 평가 (Flexural Behaviors of Pretensioned Prestressed Girders with 80MPa High-Strength Concrete)

  • 신현오;이재성;신현양;박동규;김재기;윤영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.1-2
    • /
    • 2010
  • 본 연구는 80MPa 고강도 프리텐션 거더의 휨성능 평가를 실시하였으며, 이를 통해 고강도 콘크리트의 적용가능성을 평가하고자 하였다.

  • PDF