A Mechanical Model of the End Anchorage Zone of Prestressed Concrete Members

  • Kang, Won-Ho;You, Young-Min;Oh, Seung-Hyun;Lee, Sang-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.35-41
    • /
    • 2006
  • It is expected that recent development of mechanical models will soon supersede previous empirical methods of detailing. In this study, a mechanical model is proposed to analyze the behavior of the anchorage zone of prestressed concrete members. The main characteristics of the proposed model lies in its rational consideration of material properties such as concrete strength in biaxial stress state and that of local zone reinforced by spirals. The shear friction strength of concrete surrounding a spiral is also considered. The computational results of the proposed model as well as the existing Strut-and-Tie model(STM) and nonlinear finite element analysis are compared with experimental results. The results of the comparison revealed that the proposed model showed better prediction of the failure mode as well as the failure load. Additionally, the proposed model also explained the three-dimensional failure mechanism very well, while other methods based on two-dimensional analysis could not do so well.

Stress intensity factors for double-edged cracked steel beams strengthened with CFRP plates

  • Wang, Hai-Tao;Wu, Gang;Pan, Yu-Yang;Zakari, Habeeb M.
    • Steel and Composite Structures
    • /
    • 제33권5호
    • /
    • pp.629-640
    • /
    • 2019
  • This paper presents a theoretical and finite element (FE) study on the stress intensity factors of double-edged cracked steel beams strengthened with carbon fiber reinforced polymer (CFRP) plates. By simplifying the tension flange of the steel beam using a steel plate in tension, the solutions obtained for the stress intensity factors of the double-edged cracked steel plate strengthened with CFRP plates were used to evaluate those of the steel beam specimens. The correction factor α1 was modified based on the transformed section method, and an additional correction factor φ was introduced into the expressions. Three-dimensional FE modeling was conducted to calculate the stress intensity factors. Numerous combinations of the specimen geometry, crack length, CFRP thickness and Young's modulus, adhesive thickness and shear modulus were analyzed. The numerical results were used to investigate the variations in the stress intensity factor and the additional correction factor φ. The proposed expressions are a function of applied stress, crack length, the ratio between the crack length and half the width of the tension flange, the stiffness ratio between the CFRP plate and tension flange, adhesive shear modulus and thickness. Finally, the proposed expressions were verified by comparing the theoretical and numerical results.

조립식 프리스트레스트 콘크리트 교각의 비탄성거동에 관한 해석적 연구 (Analytical Study on the Inelastic Behavior of Precast Segmental Prestressed Concrete Bridge Piers)

  • 김태훈;진병무;김영진;신현목
    • 한국지진공학회논문집
    • /
    • 제9권5호
    • /
    • pp.29-40
    • /
    • 2005
  • 이 연구의 목적은 조립식 프리스트레스트 콘크리트 교각의 비탄성 거동을 파악하는데 있다. 사용된 프로그램은 철근콘크리트 구조물의 해석을 위한 RCAHEST이다. 재료적 비선형성에 대해서는 균열콘크리트에 대한 인장, 압축, 전단모델과 콘크리트 속에 있는 철근모델을 조합하여 고려하였다. 사용된 비부착 텐던요소는 유한요소법에 근거하며 프리스트레스트 콘크리트 부재의 콘크리트와 텐던의 상호작용을 구현할 수 있다. 개발된 접합요소는 세그먼트 접합부의 비탄성거동을 예측할 수 있다. 이 연구에서는 조립식 프리스트레스트 콘크리트 교각의 비탄성 거동의 파악을 위해 제안한 해석기법을 신뢰성 있는 연구자의 실험결과와 비교하여 그 타당성을 검증하였다.

조립식 프리스트레스트 콘크리트 교각의 접합부에 관한 해석적 연구 (Analytical Study on Joints in Precast Segmental Prestressed Concrete Bridge Piers)

  • 김태훈;진병무;김영진;신헌목
    • 한국지진공학회논문집
    • /
    • 제11권1호
    • /
    • pp.79-87
    • /
    • 2007
  • 이 논문에서는 조립식 프킥스트레스트 콘크리트 교각의 접합부에 관한 해석기법을 제시하였다. 사용된 프로그램은 철근콘크리트 구조물의 해석을 위한 RCAHEST이다. 재료적 비선형성에 대해서는 균열콘크리트에 대한 인장, 압축, 전단모델과 콘크리트 속에 있는 철근모델을 조합하여 고려하였다. 사용된 비부착 텐던요소는 유한요소법에 근거하며 프리스트레스트 콘크리트 부재의 콘크리트와 텐던의 상호작용을 구현할 수 있다. 개발된 접합요소는 세그먼트 접합부의 비탄성거동을 예측할 수 있다. 이 연구에서는 조립식 프리스트레스트 콘크리트 교각의 접합부에 관한 해석기법을 신뢰성 있는 연구자의 실험결과와 비교하여 그 타당성을 검증하였다.

프리스트레스가 도입된 강섬유보강콘크리트의 균열면 전단거동 (Shear Behavior of Prestressed Steel Fiber-Reinforced Concrete at Crack Interfaces)

  • 갈경완;황진하;이득행;김강수;최일섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.78-88
    • /
    • 2012
  • 일반적으로 콘크리트는 경제성이 뛰어나지만 낮은 인장강도로 인하여 구조성능상의 한계를 가지고 있기 때문에 콘크리트와 결합된 다양한 합성재료의 특성을 활용한 구조부재의 개발이 진행되고 있다. 강섬유 보강 콘크리트(SFRC)는 높은 인장강도로 인하여 콘크리트의 재료적 단점을 보완할 수 있는 우수한 합성재료로서 알려져 있고, 특히 고강도 콘크리트의 화재시 폭렬현상에 대한 대안으로 여겨지고 있다. 또한, 프리스트레스트콘크리트(PSC) 부재는 장경간 구조에 매우 유리하며 일반철근콘크리트(RC) 부재에 비해 높은 전단강도를 가진다. 따라서, 이 연구에서는 SFRC에 프리스트레스를 적용한 강섬유 보강 프리스트레스트 콘크리트(SFR-PSC)부재의 전단거동을 이해하기 위하여 총 22개의 직접전단실험체를 제작하여 실험을 수행하였다. 또한, 실험결과를 바탕으로 SFR-PSC부재의 균열면에서의 균열전달 구성방정식을 제안하였다. SFR-PSC의 거동특성을 반영하여 제안된 재료관계식은 실험결과와 잘 일치하는 것으로 나타났다.

Long-gauge 광섬유 센서를 이용한 철도교 PSC 거더의 처짐유추 (Deflection Estimation of a PSC Railroad Girder using Long-gauge Fiber Optic Sensors)

  • 정원석;김성일;김남식;이희업
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.467-472
    • /
    • 2006
  • This paper deals with the applicability of long-gauge deformation fiber optic sensors (FOS) to prestressed concrete structures. A main motivation is the desire to monitor the deflection of the railway bridges without intervenes of the signal intensity fluctuations. A 25 m long, 1.8 m deep PSC girder was fabricated compositely with 22 cm thick reinforced concrete deck. Two pairs of 3 m long-gauge sensors are attached to the prestressed concrete girder with parallel topology. Using the relationship between curvature and vortical deflection and the quadratic regression of curvatures at the discrete point, it is possible to extrapolate the deflection curve of the girder. The estimated deflection based on the developed method is compared with the results using conventional strain gauges and LVDTS. It has been demonstrated that the proposed instrumentation technique is capable of estimating the vertical deflection and neutral axis position of the prestressed concrete girder up to weak nonlinear region.

부식을 고려한 콘크리트 교량의 최대 균열폭 제어 (Maximum Crack Width Control in Concrete Bridges Affected By Corrosion)

  • 조태준
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.114-121
    • /
    • 2006
  • As one of the serviceability limit states, the prediction and control of crack width in reinforced concrete bridges or PSC bridges are very important for the design of durable structures. However, the current bridge design specifications do not provide quantitative information for the prediction and control of crack width affected by the initiation and propagation of corrosion. Considering life span of concrete bridges, an improved control equation about the crack width affected by time-dependent general corrosion is proposed. The developed corrosion and crack width control models can be used for the design and the maintenance of prestressed and non-prestressed reinforcements by varying time, w/c, cover depth, and geometries of the sections. It can also help the rational criteria for the quantitative management and the prediction of remaining life of concrete structures.

외부강선으로 보강되는 PSC I 합성거더의 해석 기법 (Analytical Method on PSC I Girder with Strengthening of External Tendon)

  • 박재근;이병주;김문영;신현목
    • 콘크리트학회논문집
    • /
    • 제20권6호
    • /
    • pp.697-704
    • /
    • 2008
  • 이 논문은 외부 강선으로 보강된 PSC 교량의 시공단계가 고려된 비선형거동 예측을 위한 연구이다. 해석시 비부착 텐던 요소와 유연도법에 근거한 보-기둥 요소를 사용하였다. 비부착 텐던 모델은 PSC 구조물의 콘크리트내의 텐던의 거동을 모사하며 포스트텐션 (posttensioned) 구조물의 프리스트레싱력과 전달을 효율적으로 모사할 수 있다. 이 모델은 여러 절점과 세그먼트로 구성되며 PSC 구조물내의 같은 위치의 텐던을 하나의 텐던 요소로 모사할 수 있다. 보-기둥 요소는 분산균열 개념에 기초한 철근콘크리트 비선형 재료모델을 포함하고 있다. 유연도법에 근거하여 유도된 보-기둥 요소의 각각의 파이버는 콘크리트와 철근의 일축 거동을 모사한다. 보-기둥요소와 비부착 텐던 요소는 RC 및 PSC 구조물의 상세 비선형해석을 수행할 수 있는 RCAHEST (reinforce concrete analysis in higher evaluation system technology)에 이식하였다. 외부 강선으로 보강된 PSC 구조물에 대한 수치기법은 신뢰성 있는 실험 결과와 비교하여 검증하였다.

Fatigue behavior of concrete beams reinforced with HRBF500 steel bars

  • Li, Ke;Wang, Xin-Ling;Cao, Shuang-Yin;Chen, Qing-Ping
    • Structural Engineering and Mechanics
    • /
    • 제53권2호
    • /
    • pp.311-324
    • /
    • 2015
  • The purpose of this study was to investigate experimentally the fatigue performance of reinforced concrete (RC) beams with hot-rolled ribbed fine-grained steel bars of yielding strength 500MPa (HRBF500). Three rectangular and three T-section RC beams with HRBF500 bars were constructed and tested under static and constant-amplitude cyclic loading. Prior to the application of repeated loading, all beams were initially cracked under static loading. The major test variables were the steel ratio, cross-sectional shape and stress range. The stress evolution of HRBF500 bars, the information about crack growth and the deflection developments of test beams were presented and analyzed. Rapid increases in deflections and tension steel stress occured in the early stages of fatigue loading, and were followed by a relatively stable period. Test results indicate that, the concrete beams reinforced with appropriate amount of HRBF500 bars can survive 2.5 million cycles of constant-amplitude cyclic loading with no apparent signs of damage, on condition that the initial extreme tensile stress in HRBF500 steel bars was controlled less than 150 MPa. It was also found that, the initial extreme tension steel stress, stress range, and steel ratio were the main factors that affected the fatigue properties of RC beams with HRBF500 bars, whose effects on fatigue properties were fully discussed in this paper, while the cross-sectional shape had no significant influence in fatigue properties. The results provide important guidance for the fatigue design of concrete beams reinforced with HRBF500 steel bars.

New technique for strengthening reinforced concrete beams with composite bonding steel plates

  • Yang, Su-hang;Cao, Shuang-yin;Gu, Rui-nan
    • Steel and Composite Structures
    • /
    • 제19권3호
    • /
    • pp.735-757
    • /
    • 2015
  • Composite bonding steel plate (CBSP) is a newly developed type of structure strengthened technique applicable to the existing RC beam. This composite structure is applicable to strengthening the existing beam bearing high load. The strengthened beam consists of two layers of epoxy bonding prestressed steel plates and the RC beam sandwiched in between. The bonding enclosed and prestressed U-shaped steel jackets are applied at the beam sides. This technique is adopted in case of structures with high longitudinal reinforcing bar ratio and impracticable unloading. The prestress can be generated on the strengthening steel plates and jackets by using the CBSP technique before loading. The test results of full-scale CBSP strengthened beams show that the strength and stiffness are enhanced without reduction of their ductility. It is demonstrated that the strain hysteresis effect can be effectively overcome after prestressing on the steel plates by using such technique. The applied plates and jackets can jointly behave together with the existing beam under the action of epoxy bonding and the mechanical anchorage of the steel jackets. The simplified formulas are proposed to calculate the prestress and the ultimate capacities of strengthened beams. The accuracy of formulas was verified with the experimental results.