• Title/Summary/Keyword: pressurized pipe

Search Result 68, Processing Time 0.025 seconds

Ratcheting boundary of pressurized pipe under reversed bending

  • Chen, Xiaohui;Chen, Xu;Li, Zifeng
    • Steel and Composite Structures
    • /
    • v.32 no.3
    • /
    • pp.313-323
    • /
    • 2019
  • Ratcheting boundary is firstly determined by experiment, elastic-plastic finite element analysis combined with C-TDF and linear matching method, which is compared with ASME/KTA and RCC-MR. Moreover, based on elastic modulus adjustment procedure, a novel method is proposed to predict the ratcheting boundary for a pressurized pipe subjected to constant internal pressure and cyclic bending loading. Comparison of ratcheting boundary of elbow pipe determined by the proposed method, elastic-plastic finite element analysis combined with C-TDF and linear matching method, which indicates that the predicted results of the proposed method are in well agreement with those of linear matching method.

Effect of local wall thinning on ratcheting behavior of pressurized 90° elbow pipe under reversed bending using finite element analysis

  • Chen, Xiaohui;Chen, Xu
    • Steel and Composite Structures
    • /
    • v.20 no.4
    • /
    • pp.931-950
    • /
    • 2016
  • Ratcheting deformation of pressurized Z2CND18.12N stainless steel $90^{\circ}$ elbow pipe with local wall thinning subjected to constant internal pressure and reversed bending was studied using finite element analysis. Chen-Jiao-Kim (CJK) kinematic hardening model, which was used to simulate ratcheting behavior of pressurized $90^{\circ}$ elbow pipe with local wall thinning at extrados, flanks and intrados, was implemented into finite element software ANSYS. The local wall thinning was located at extrados, flanks and intrados of $90^{\circ}$ elbow pipe, whose geometry was rectangular cross-section. The effect of depth, axial length and circumferential angle of local wall thinning at extrados, flanks and intrados on the ratcheting behaviors of $90^{\circ}$ elbow pipe were studied in this paper. Three-dimensional elastic-plastic analysis with Chen-Jiao-Kim (CJK) kinematic hardening model was carried out to evaluate structural ratcheting behaviors. The results indicated that ratcheting strain was generated mainly along the hoop direction, while axial ratcheting strain was relatively small.

An Analysis on the Effect of Pressure System Installation on the Pipeline to Identify Pressurized Water and Self-inspection Ease in Apartment Building (아파트에 설치하는 옥내소화전 압력계 설치가 배관의 가압수 식별 및 자체점검 용이성 간의 영향 분석)

  • Son, Joo-Dal;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.33-44
    • /
    • 2020
  • This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study's results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building's stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system's internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.

Evaluation of Pressurized Water Mixing of Big Pipe with CFD at Water Treatment Process (CFD를 활용한 수처리공정 대형관에서 압력수 혼합공정 평가)

  • Cho, Young-Man;Yu, Hyun-chul;Jang, Gyeong-Hyuk;Jung, Yong-Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.3
    • /
    • pp.168-174
    • /
    • 2021
  • Mixing is a very important unit in water treatment process. A mechanical stirring method is generally used for mixing, but recently, the use of pressurized water mixing method (pump diffusion flash mixer) has gained interest because it is more advantageous in terms of mixing time, noise, energy consumption, and maintenance. The following conclusions were obtained from the study of pressurized water mixing method by Computational Fluid Dynamics. Firstly, the mixing degree in the pipe increased as the density of water increased. Secondly, even if the relative velocity between flow rate in the pipe and the pressurized water was constant, the mixing degree decreased as the flow velocity in the pipe increased. Thirdly, the stronger the injection energy the higher the mixing degree. It was also found that the mixing degree was greatly affected by the injection velocity as compared to the injection flow amount. Finally, the required energy to achieve 95% mixing degree at the distance of 10 times diameter in big pipes of 500 mm to 3000 mm was 0.3 to 4.5 kJ. The result of this study could be used in the process design of injection with water purification chemicals, such as, ozone, chlorine, and coagulant.

Bending ratcheting behavior of pressurized straight Z2CND18.12N stainless steel pipe

  • Wang, Lei;Chen, Gang;Zhu, Jianbei;Sun, Xiuhu;Mei, Yunhui;Ling, Xiang;Chen, Xu
    • Structural Engineering and Mechanics
    • /
    • v.52 no.6
    • /
    • pp.1135-1156
    • /
    • 2014
  • The ratcheting effect greatly challenges the design of piping components. With the assistance of the quasi-three point bending apparatus, ratcheting and the ratcheting boundary of pressurized straight Z2CND18.12N stainless steel pipe under bending loading and vertical displacement control were studied experimentally. The characteristics of progressive inelastic deformation in axial and hoop directions of the Z2CND18.12N stainless steel pipes were investigated. The experiment results show that the ratcheting strain occurs mainly in the hoop direction while there is less ratcheting strain in the axial direction. The characteristics of the bending ratcheting behavior of the pressure pipes were derived and compared under load control and displacement control, respectively. The results show that the cyclic bending loading and the internal pressure affect the ratcheting behavior of the pressurized straight pipe significantly under load control. In the meantime, the ratcheting characteristics are also highly associated with the cyclic displacement and the internal pressure under displacement control. All these factors affect not only the saturation of the ratcheting strain but the ratcheting strain rate. A series of multi-step bending ratcheting experiments were conducted under both control modes. It was found that the hardening effect of Z2CND18.12N stainless steel pipe under previous cyclic loadings no matter with high or low displacement amplitudes is significant, and the prior loading histories greatly retard the ratcheting strain and its rate under subsequent loadings. Finally, the ratcheting boundaries of the pressurized straight Z2CND18.12N stainless steel pipe were determined and compared based on KTA/ASME, RCC-MR and the experimental results.

Comprehensive Consideration on the Discharge of Gases from Pressurized Vessels through Pressure Relief Devices (압력용기로부터 압력방출장치를 통한 가스 방출에 관한 포괄적 고찰)

  • Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.32-45
    • /
    • 2020
  • The problem of determining the discharge rates of gases from pressurized vessels through pressure relief devices was dealt with comprehensively. First, starting from basic fluid flow equations, detailed modeling procedures were presented for isentropic nozzle flows and frictional flows in a pipe, respectively. Meanwhile, physical explanations were given to choking phenomena in terms of the acoustic velocity, elucidating the widespread use of Mach numbers in gas flow models. Frictional flows in a pipe were classified into adiabatic, isothermal, and general flows according to the heat transfer situation around the pipe, but the adiabatic flow model was recommended suitable for gas discharge through pressure relief devices. Next, for the isentropic nozzle flow followed by adiabatic frictional flow in the pipe, two equations were established for two unknowns that consist of the Mach numbers at the inlet and outlet of the pipe, respectively. The relationship among the ratio of downstream reservoir pressure to upstream pressure, mass flux, and total frictional loss coefficient was shown in various forms of MATLAB 2-D plot, 3-D surface plot and contour plot. Then, the profiles of gas properties and velocity in the pipe section were traced. A method to quantify the relationship among the pressure head, velocity head, and total friction loss was presented, and was used in inferring that the rapid increase in gas velocity in the region approaching the choked flow at the pipe outlet is attributed to the conversion of internal energy to kinetic energy. Finally, the Levenspiel chart reproduced in this work was compared with the Lapple chart used in API 521 Standatd.

Ratcheting behavior of pressurized Z2CND18.12N stainless steel pipe under different control modes

  • Chen, Xiaohui;Chen, Xu;Chen, Gang;Li, Duomin
    • Steel and Composite Structures
    • /
    • v.18 no.1
    • /
    • pp.29-50
    • /
    • 2015
  • With a quasi-three point bending apparatus, ratcheting deformation is studied experimentally on a pressurized austenitic stainless steel Z2CND18.12N pipe under bending load and vertical displacement control, respectively. The characteristic of ratcheting behavior of straight pipe under both control methods is achieved and compared. The cyclic bending loading and internal pressure influence ratcheting behavior of pressurized straight pipe significantly under loading control and the ratcheting characteristics are also highly associated with the cyclic displacement and internal pressure under displacement control. They all affect not only the saturation of the ratcheting strain but the ratcheting strain rate. In addition, ratcheting simulation is performed by elastic-plastic finite element analysis with ANSYS in which the bilinear model, Chaboche model, Ohno-Wang model and modified Ohno-Wang model are applied. By comparison with the experimental data, it is found that the CJK model gives reasonable simulation. Ratcheting boundaries under two control modes are almost same.

Evaluation of Pressurized Water Diffusion in Water Treatment Process Using CFD (전산유체역학(CFD)를 활용한 정수공정에서 압력수 확산공정 진단)

  • Cho, Young-Man;Yoo, Soo-Jeon;Roh, Jae-Soon;Bin, Jae-Hoon;Choe, Kwang-Ju;Lee, Kwang-Ug;Lee, Gi-Bong;Lee, Jeong-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.359-367
    • /
    • 2011
  • The Process of Pressurized water diffusion is mixing process by pressurized water injection with coagulate and chlorine water in the water treatment system. The objectives of this research were to evaluate the mixing length and diameter of diffusion plate and distance from injection pipe for complete mixing by using computational fluid dynamics. From the results of CFD simulation, when diameter of injection pipe is 50 mm, 100 mm and injection pressure is $5kg/cm^2$ and the diameter of inlet pipe is 2,200 mm, the complete mixing length is 4D (D: Length as diameter of inlet pipe). When diameter of injection pipe is 50 mm, the diameter of the diffusion plate in o.1D and distance from injection pipe is 0.2D, the complete mixing length is 3D that is the most short mixing length. But when diameter of injection pipe is 100 mm and mutually related the diameter, distance of diffusion plate, the complete mixing length is 4D over. Therefore, as the diameter of inlet pipe is 2,200 mm, the injection pipe 50 mm is more efficient than 100 mm.

Comparative Study on Water Hammer for Pump Station in High Pressurized Pipes in Kuwait

  • Shim, Kyu Dae;Kang, Yong Suk;Choung, Joon Yeon;Abdellatif, Mohamed;Kim, Dong Kyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.265-269
    • /
    • 2017
  • Because of abrupt changes for velocity in water, transient flow is occurred in practical life. To reduce and avoid the high or low pressure of pipe network system, various surge protection facilities are used to prevent the risk in pipe network system. Especially, we focused on study not only preventing positive and negative pressure but also selecting adequate equipment for high pressurized pipelines. Several critical cases were considered by undertaking a steady state hydraulic study and transient dynamic simulation and we suggested that the surge vessel of various surge protection system was recommended to control high and low pressures on pipeline system in perspective.

  • PDF

Development of a Guided Wave Technique for the Inspection of a Feeder Pipe in a Pressurized Heavy Water Reactor

  • Cheong, Yong-Moo;Lee, Dong-Hoon;Kim, Sang-Soo;Jung, Hyun-Kyu
    • Corrosion Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.108-113
    • /
    • 2005
  • One of the recent safety issues in the pressurized heavy water reactor (PHWR) is the cracking of the feeder pipe. Because of the limited accessibility to the cracked region and a high dose of radiation exposure, it is difficult to inspect all the pipes with the conventional ultrasonic method. In order to solve this problem, a long-range guided wave technique has been developed. A computer program to calculate the dispersion curves in the pipe was developed and the dispersion curves for the feeder pipes in PHWR plants were determined. Several longitudinal and/or flexural modes were selected from the review of the dispersion curves and an actual experiment has been carried out with the specific alignment of the piezoelectric ultrasonic transducers. They were confirmed as L(0,1)) and/or flexural modes(F(m,2)) by the short time Fourier transformation(STFT) and were sensitive to the circumferential cracks, but not to the axial cracks in the pipe. An electromagnetic acoustic transducers(EMAT) was designed and fabricated for the generation and reception of the torsional guided wave. The axial cracks were detected by a torsional mode(T(0,1)) generated by the EMAT.