• Title/Summary/Keyword: pressurization

Search Result 337, Processing Time 0.028 seconds

SBLOCA AND LOFW EXPERIMENTS IN A SCALED-DOWN IET FACILITY OF REX-10 REACTOR

  • Lee, Yeon-Gun;Park, Il-Woong;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.347-360
    • /
    • 2013
  • This paper presents an experimental investigation of the small-break loss-of-coolant accident (SBLOCA) and the loss-of-feedwater accident (LOFW) in a scaled integral test facility of REX-10. REX-10 is a small integral-type PWR in which the coolant flow is driven by natural circulation, and the RCS is pressurized by the steam-gas pressurizer. The postulated accidents of REX-10 include the system depressurization initiated by the break of a nitrogen injection line connected to the steam-gas pressurizer and the complete loss of normal feedwater flow by the malfunction of control systems. The integral effect tests on SBLOCA and LOFW are conducted at the REX-10 Test Facility (RTF), a full-height full-pressure facility with reduced power by 1/50. The SBLOCA experiment is initiated by opening a flow passage out of the pressurizer vessel, and the LOFW experiment begins with the termination of the feedwater supply into the helical-coil steam generator. The experimental results reveal that the RTF can assure sufficient cooldown capability with the simulated PRHRS flow during these DBAs. In particular, the RTF exhibits faster pressurization during the LOFW test when employing the steam-gas pressurizer than the steam pressurizer. This experimental study can provide unique data to validate the thermal-hydraulic analysis code for REX-10.

Effect of Final Annealing and Stress on Creep Behavior of HANA Zirconium Fuel Claddings (HANA 지르코늄 핵연료피복관의 크립거동에 미치는 최종 열처리 및 응력의 영향)

  • Kim, H.G.;Kim, J.H.;Jeong, Y.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.4
    • /
    • pp.235-241
    • /
    • 2005
  • Thermal creep properties of the advanced zirconium fuel claddings named by HANA alloys which were developed for high burn-up application were evaluated. The creep test of HANA cladding tubes was carried out by the internal pressurization method in temperature range from 350 to $400^{\circ}C$ and in the hoop stress range from 100 to 150 MPa. Creep tests were lasted up to 800 days, which showed the steady-state secondary creep rate. The creep resistance of HANA fuel claddings was affected by final annealing temperature and various factors, such as alloying element, applied stress and testing temperature. From the results the microstructure observation of the samples before and after creep test by using TEM, the dislocation density was increased in the sample of after creep test. The Sn as an alloying element was more effective in the creep resistance than other elements such as Nb, Fe, Cr and Cu due to solute hardening effect of Sn. In case of HANA fuel claddings, the improved creep resistance was obtained by the control of final heat treatment temperature as well as alloying element.

A Study on the Calculation Method of Infiltration for Detached Houses (기존 단독주택의 침기량 산정법에 관한 연구)

  • Kim, Giltae;Yoo, Jung-Hyun;Hwang, Ha-Jin;Kim, Kyoung-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.493-498
    • /
    • 2013
  • The purpose of this study is to find the infiltration of detached houses, for energy consumption analyses. The pressurization and depressurization method is used to determine infiltration. Blower door tests are expressed in terms of ACH 50, which stands for the hourly air change rate at 50 Pa of fan pressure. The ACH 50 of existing Detached Houses ranges from 5 to 50. Air infiltration is related to construction year and accuracy, maintenance conditions, and so on. When estimating the infiltration of random detached houses, the year used can be the base value of the infiltration rate from 0.25 to 2.0 times/h. The maintenance conditions, construction accuracy and repair affect the air infiltration 0 to 0.5 times/h, 0 to 0.3 times/h, 0 to 1 times/h, respectively.

Numerical analysis of melting process in a water tank for fuel-cell vehicles (연료전지 자동차의 물탱크 해빙과정에 대한 수치해석적 연구)

  • Kim, Hark-Koo;Jeong, Si-Young;Hur, Nahm-Keon;Lim, Tae-Won;Park, Yong-Sun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.74-79
    • /
    • 2006
  • Good cold start characteristics are essential for satisfactory operation of fuel cell vehicles. In this study, the melting process has been numerically investigated for a water tank frozen in cold weather The 2-D model of the tank containing ice and plate heaters was assumed and the unsteady melting process of the ice was calculated. The enthalpy method was used for the description of the melting process, and a FVM code was used to solve the problem. The feasibility study compared with other experiment showed that the developed program was able to describe the melting process well. From the numerical analysis carried out for different wall temperatures of the pate heaters, some important design factors could be found such as local overheating and pressurization in the tank.

  • PDF

SAFETY OF THE SUPER LWR

  • Ishiwatari, Yuki;Oka, Yoshiaki;Koshizuka, Seiichi
    • Nuclear Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.257-272
    • /
    • 2007
  • Supercritical water-cooled reactors (SCWRs) are recognized as a Generation IV reactor concept. The Super LWR is a pressure-vessel type thermal spectrum SCWR with downward-flow water rods and is currently under study at the University of Tokyo. This paper reviews Super LWR safety. The fundamental requirement for the Super LWR, which has a once-through coolant cycle, is the core coolant flow rate rather than the coolant inventory. Key safety characteristics of the Super LWR inhere in the design features and have been identified through a series of safety analyses. Although loss-of-flow is the most important abnormality, fuel rod heat-up is mitigated by the "heat sink" and "water source" effects of the water rods. Response of the reactor power against pressurization events is mild due to a small change in the average coolant density and flow stagnation of the once-through coolant cycle. These mild responses against transients and also reactivity feedbacks provide good inherent safety against anticipated-transient-without-scram (ATWS) events without alternative actions. Initiation of an automatic depressurization system provides effective heat removal from the fuel rods. An "in-vessel accumulator" effect of the reactor vessel top dome enhances the fuel rod cooling. This effect enlarges the safety margin for large LOCA.

ANALYSIS OF PRESTRESSED CONCRETE CONTAINMENT VESSEL (PCCV) UNDER SEVERE ACCIDENT LOADING

  • Noh, Sang-Hoon;Moon, Il-Hwan;Lee, Jong-Bo;Kim, Jong-Hak
    • Nuclear Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.77-86
    • /
    • 2008
  • This paper describes the nonlinear analyses of a 1:4 scale model of a prestressed concrete containment vessel (PCCV) using an axisymmetric model and a three-dimensional model. These two models are refined by comparison of the analysis results and with testing results. This paper is especially focused on the analysis of behavior under pressure and the temperature effects revealed using an axisymmetric model. The temperature-dependent degradation properties of concrete and steel are considered. Both geometric and material nonlinearities, including thermal effects, are also addressed in the analyses. The Menetrey and Willam (1995) concrete constitutive model with non-associated flow potential is adopted for this study. This study includes the results of the predicted thermal and mechanical behaviors of the PCCV subject to high temperature loading and internal pressure at the same time. To find the effect of high temperature accident conditions on the ultimate capacity of the liner plate, reinforcement, prestressing tendon and concrete, two kinds of analyses are performed: one for pressure only and the other for pressure with temperature. The results from the test on pressurization, analysis for pressure only, and analyses considering pressure with temperatures are compared with one another. The analysis results show that the temperature directly affects the behavior of the liner plate, but has little impact on the ultimate pressure capacity of the PCCV.

Circumferential steady-state creep test and analysis of Zircaloy-4 fuel cladding

  • Choi, Gyeong-Ha;Shin, Chang-Hwan;Kim, Jae Yong;Kim, Byoung Jae
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2312-2322
    • /
    • 2021
  • In recent studies, the creep rate of Zircaloy-4, one of the basic property parameters of the nuclear fuel code, has been commonly used with the axial creep model proposed by Rosinger et al. However, in order to calculate the circumferential deformation of the fuel cladding, there is a limitation that a difference occurs depending on the anisotropic coefficients used in deriving the circumferential creep equation by using the axial creep equation. Therefore, in this study, the existing axial creep law and the derived circumferential creep results were analyzed through a circumferential creep test by the internal pressurization method in the isothermal conditions. The circumferential creep deformation was measured through the optical image analysis method, and the results of the experiment were investigated through constructed IDECA (In-situ DEformation Calculation Algorithm based on creep) code. First, preliminary tests were performed in the isotropic β-phase. Subsequently in the anisotropic α-phase, the correlations obtained from a series of circumferential creep tests were compared with the axial creep equation, and optimized anisotropic coefficients were proposed based on the performed circumferential creep results. Finally, the IDECA prediction results using optimized anisotropic coefficients based on creep tests were validated through tube burst tests in transient conditions.

A novel low resistivity copper diffusion joint for REBa2Cu3O7-δ tapes by thermocompression bonding in air

  • Wei, Ren;Zhen, Huang;Fangliang, Dong;Yue, Wu;Zhijian, Jin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.16-24
    • /
    • 2022
  • Applications of REBa2Cu3O7-δ tapes require joints with a simple manufacturing process, low resistance and good mechanical properties. In the present study, we successfully developed a copper diffusion joint between Cu-stabilized REBa2Cu3O7-δ tapes that meets the above requirements without solder simply by applying flux, heat and pressurization. After a 3 min thermocompression process at approximately 150 δ and 336 MPa in air, two tapes were directly connected between Cu stabilizers by copper diffusion, which was proven by microstructure analysis. The specific resistivity of the copper diffusion joint reached 5.8 nΩ·cm2 (resistance of 0.4 nΩ for a 306 mm splicing length) at 77 K in the self-field. The axial tensile stress reached 200 N without critical current degradation. The results show promise for the preparation of copper diffusion joints to be used in coils, attached tapes, and wire/cable terminals.

Role of Esophageal High-Resolution Manometry in Pediatric Patients

  • Prachasitthisak, Noparat;Purcell, Michael;Krishnan, Usha
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.4
    • /
    • pp.300-311
    • /
    • 2022
  • Purpose: Dysphagia, vomiting and feeding difficulties are common symptoms, with which children present. Esophageal function testing with high resolution manometry can help in diagnosing and treating these patients. We aim to access the clinical utility of high-resolution manometry of esophagus in symptomatic pediatric patients. Methods: A retrospective chart review was done on all symptomatic patients who underwent esophageal high-resolution manometry between 2010 and 2019 at Sydney Children's Hospital, Australia. Manometry results were categorized based on Chicago classification. Demographic data, indication of procedure, manometric findings, and details of treatment changes were obtained and analyzed. Results: There were 62 patients with median age of 10 years (9 months-18 years). The main indication for the procedure was dysphagia (56%). Thirty-two percent of patients had a co-morbid condition, with esophageal atresia accounting for 16%. The majority (77%) of patients had abnormal manometry which included, ineffective esophageal motility in 45.2%. In esophageal atresia cohort, esophageal pressurization was seen in 50%, aperistalsis in 40% and 10% with prior fundoplication had esophago-gastric junction obstruction. Patients with esophago-gastric junction obstruction or achalasia were treated by either pneumatic dilation or Heller's myotomy. Patients with ineffective esophageal motility and rumination were treated with a trial of prokinetics/dietary texture modification and diaphragmatic breathing. Conclusion: Esophageal high-resolution manometry has a role in the evaluation of symptomatic pediatric patients. The majority of our patients had abnormal results which led to change in treatments, with either medication, surgery and/or feeding modification with resultant improvement in symptoms.

Development of PSA Process for Medical Oxygen Generator (의료용 산소발생기 제작을 위한 PSA 공정의 개발)

  • Choi, Jae-Wook;Na, Byung-Ki
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.75-80
    • /
    • 2009
  • In order to separate oxygen from air, the effects of feed gas flow rate and rinse gas flow rate on the product purity and flow were examined using 2 bed PSA with 4 step cycle. The addition of product pressurization step increased the product purity and flow rate. The addition of pressure equalization increased the product flow rate. The test product was manufactured and the purity and flow rate of product oxygen was examined. The results were compared with the commercial medical oxygen generator of 5 ${\ell}/min$ and 90% oxygen purity.