• 제목/요약/키워드: pressure-volume curve

검색결과 98건 처리시간 0.024초

A semi-analytical solution to spherical cavity expansion in unsaturated soils

  • Tang, Jianhua;Wang, Hui;Li, Jingpei
    • Geomechanics and Engineering
    • /
    • 제25권4호
    • /
    • pp.283-294
    • /
    • 2021
  • This paper presents a rigorous solution for spherical cavity expansion in unsaturated soils under constant suction condition. The hydraulic behavior that describes the saturation-suction relationship is modeled by a void ratio-dependent soil-water characteristic curve, which allows the hydraulic behavior to fully couple with the mechanical behavior that is described by an extended critical state soil model for unsaturated soil through the specific volume. Considering the boundary condition and introducing an auxiliary coordinate, the problem is formulated to a system of first-order differential equations with three principal stress components and suction as basic unknowns, which is solved as an initial value problem. Parameter analyses are conducted to investigate the effects of suction and the overconsolidation ratio on the overall expansion responses, including the pressure-expansion response, the distribution of the stress components around the cavity, and the stress path of the soil during cavity expansion. The results reveal that the expansion pressures and the distribution of the stress components in unsaturated soils are generally higher than those in saturated soils due to the existence of suction.

피록시캄이 니페디핀의 약력학 및 약동학에 미치는 영향 (Effects of Piroxicam on Pharmacodynamics and Pharmacokinetics of Nifedipine in Spontaneously Hypertensive Rats)

  • 최기환;박인숙;김동섭;정혜주
    • 약학회지
    • /
    • 제44권3호
    • /
    • pp.245-250
    • /
    • 2000
  • Because nonsteroidal anti-inflammatory drugs are reported to cause fluid retention and hypertension by inhibition of prostaglandin synthesis, the effects of piroxicam on pharmacodynamics and pharmacokinetics of nifedipine were studied in male spontaneously hypertensive rats. They received nifedipine (0.5 mg/kg) alone or combined with piroxicam (5 mg/kg) intravenously. Plasma levels norepinephrine, an index of sympathetic stimulation, were measured prior to each treatment and 5 min after drug administration. Changes in blood pressure were examined serially and blood samples for analysis of nifedipine were also taken for 6 hr following drug administration. Plasma nifedipine concentration were assayed by HPLC and pharmacokinetic parameters were calculated. Blood pressure was reduced (p<0.01), but plasma norepinephrine level was increased (p<0.05) by nifedipine administration. Anti-hypertensive effect of nifedipine was potentiated (p<0.05) by piroxicam coadministration, but effect of nifedipine on plasma norepinephrine level was not affected. In case of rats received nifedipine and piroxicam, plasma nifedipine concentrations were higher (p<0.05) than those from rats received nifedipine alone at 2,3,4,5 and 6 hours following drug administration. The area under the plasma concentration vs. time curve was increased (p<0.05), while the elimination rate constant was decreased (p<0.01) by piroxicam coadministration. No significant differences were observed in the plasma clearance, apparent volume of distribution and elimination half-life. Thus, piroxicam not only potentiated antihypertensive effect of nifedipine, but also altered nifedipine pharmacokinetics in the rats. It is concluded that the potentiation of nifedipine antihypertensive effect might correlate with the increment of its plasma concentration by piroxicam coadministration.

  • PDF

소형 냉장고에 대한 스크롤 압축기 적용성에 관한 연구 (A Study on the Applicability of a Scroll Type Compressor to Small Capacity Refrigerators)

  • 김유찬;김우영;김현진
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.164-173
    • /
    • 2012
  • To study the applicability of a scroll type compressor to small capacity refrigerators, a R600a scroll compressor with algebraic scroll wrap has been designed. Its size and performance have been compared to a reciprocating type of the same displacement volume. By employing scroll wrap based on algebraic curve, high compression ratio can be accomplished without increasing the wrap angle much so that compact scroll may be obtained. Compared to a reciprocating one, the designed scroll compressor has diameter and height reduced by about 50% and 80%, respectively. By numerical simulation, it has been estimated that the scroll compressor provides 38.6% more cooling capacity than reciprocating type with 8.9% more power consumption, resulting in 27.3% increase in COP for ASHRAE low back pressure condition. With increasing the operating pressure ratio from 9.5 to 15.3, the overall compressor efficiency of the scroll compressor decreases from 72.6% to 65.2%, while that of the reciprocating compressor increases from 55.7% to 59.8%.

비정질강섬유를 혼입한 초고강도콘크리트의 폭렬특성에 관한 실험적 연구 (Experimental Study on the Spalling Properties of Ultra High Strength Concrete containing Amorphous Metallic Fiber)

  • 최경철;김규용;김홍섭;황의철;남정수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권3호
    • /
    • pp.111-118
    • /
    • 2019
  • 본 연구에서는 비정질강섬유의 혼입이 초고강도콘크리트의 폭렬특성에 미치는 영향이 실험적으로 검토되었다. 콘크리트는 압축강도 100과 150 MPa의 초고강도콘크리트가 사용되었다. 폴리프로필렌섬유는 0.15 vol%, 비정질강섬유는 0.3 및 0.5 vol%가 혼입되었다. 시험체는 콘크리트의 압축강도와 섬유혼입 조건에 따라 6수준이 제작되었고, ISO-834 가열곡선에 의해 가열되었다. 결과로써 폴리프로필렌섬유와 비정질강섬유가 혼입된 초고강도콘크리트의 폭렬제어에 있어서는 용융된 폴리프로필렌섬유가 형성하는 공극네트워크를 통해 수증기가 이동하는 효과가 지배적인 것으로 나타났다. 또한, 비정질강섬유 0.3v ol% 혼입률에서는 폭렬제어에 큰 영향을 미치지 않지만, 0.5 vol%의 비정질강섬유가 혼입될 경우에는 수증기가 이동할 수 있는 균열의 발생이 억제됨으로써 콘크리트 폭렬의 원인으로 지적되고 있는 수분막힘층(moisture clog)가 형성될 가능성이 높은 것을 확인할 수 있었다.

다수준분석을 활용한 개인특성 및 지역환경에 따른 우울증 관련 영향요인 분석 (Related Factors of Depression according to Individual Attributes and Regional Environment: Using Multi-Level Analysis)

  • 문석준;이가람;남은우
    • 보건행정학회지
    • /
    • 제30권3호
    • /
    • pp.355-365
    • /
    • 2020
  • Background: This study is aimed to verify individual and regional-level factors affecting the depression of Koreans and to develop social programs for improving the depressive status. Methods: This study used individual-level variables from the Korean Community Health Survey (2018) and used the e-regional index of the Korean Statistical Information Service as the regional-level variable. A multi-level logistic regression was executed to identify individual and regional-level variables that were expected to affect the extent of depressive symptoms and to draw the receiver operating characteristic curve to compare the volume of impact between variables from both levels. Results: The results of the multi-level logistic regression analysis in regards to individual-level factors showed that older age, female gender, a lower income level, a lower education level, not having a spouse, the practice of walking, the consumption of breakfast higher levels of stress, and having high blood pressure or diabetes were associated with a greater increase in depressive symptoms. In terms of regional factors, areas with fewer cultural facilities and fewer car registration had higher levels of depressive symptoms. The comparison of area under the curve showed that individual factors had a greater influence than regional factors. Conclusion: This study showed that while both, individual and regional-level factors affect depression, the influence of the latter was relatively weaker as compared to the first. In this sense, it is necessary to develop programs focused on the individual, such as social prescribing at the local or community-level, rather than the city and nation-level approach that are currently prevalent.

호흡훈련보조기구를 이용한 호흡훈련 전 후의 폐기능 호흡근력과 최대발성지속시간의 변화 (Pulmonary Functionn and the Maximal Inspiratory and Expiratory Pressure, and Maximum Phonation Time Before and After the Specially Programmed Training)

  • 남도현;최홍식;안철민
    • 대한후두음성언어의학회지
    • /
    • 제14권2호
    • /
    • pp.88-93
    • /
    • 2003
  • 성악훈련을 받고있는 여학생들은 호흡훈련과 호흡훈련 보조기구를 이용하여 훈련을 하면서 발성연습을 하면 최대호기압과 최대흡기압이 증가하여 호흡근육의 근력이 증가하였다는 것을 알 수 있었으나 호흡기능에는 변화가 없어 호흡훈련에 의해 폐기능이 증진되지는 않는다는 결론을 얻게 되었다. 최대발성지속시간 역시 크게 증가하여 성악을 공부하는 학생들이 이 방법대로 훈련을 하는 것이 효과적이지 않을까 추정된다.

  • PDF

동공부피 분포의 계산결과에 미치는 표면장력의 곡률 의존도 효과 (Effect of Curvature Dependency of Surface Tension on the Result of Pore-Volume Distribution Analysis)

  • 조창현;안운선;장세헌
    • 대한화학회지
    • /
    • 제16권6호
    • /
    • pp.341-348
    • /
    • 1972
  • 질소의 흡착 등온곡선을 이용하여 흡착체의 동공부피 분포를 계산하는 과정에서 표면장력의 곡률 의존도 고려 효과를 조사하였다. 즉, 장세헌 등에 의한 표면장력의 곡률 의존도식과 캘빈 식으로부터 주어진 압력에서의 캘빈반경을 구하고, 이것으로부터 흡착체의 동공부피 분포를 계산하였다. 이와 같이하여 얻은 계산 결과를 표면장력의 곡률 의존도를 고려하지 아니한 종래방법에 의한 계산 결과와 비교하였다. 일반적으로 곡률 의존도를 고려해주면 동공부피 분포 곡선의 극대부분이 큰 동공 쪽으로 이동한다. 또한 모세관 응축이 일어나는 상대압력이 종래까지 생각했던 것보다 훨씬 낮아지고 있다. 이러한 효과들은 흡착체의 동공들이 미세해 질수록 더욱 현저하게 일어난다.

  • PDF

파이로테크닉 착화기 화약 연소 모델링 (Combustion Modeling of Explosive for Pyrotechnic Initiator)

  • 차승원;우정민;김용찬;오석환;조진연;김정호;장승교;양희원;노태성
    • 한국추진공학회지
    • /
    • 제21권6호
    • /
    • pp.39-48
    • /
    • 2017
  • PMD 산업에서 주로 사용되는 ZPP와 $BKNO_3$에 대한 연소 모델링을 수행하였다. 구성방정식으로는 Saint Robert's law와 에너지보존식, 그리고 Noble-Abel 상태방정식을 사용하였다. 구축된 연소 모델과 실제 CBT에서 얻은 압력 결과데이터를 비교하였다. ZPP의 경우, 모델이 실험 결과와 유사한 압력곡선을 예측하였지만, $BKNO_3$는 챔버의 부피가 작을 때 모델이 실험보다 큰 최대압력을 도출하였다. 이에 대해 $BKNO_3$의 미연소성을 고려하였다.

바이오폴리머를 포함한 모래지반의 흙-습윤 특성곡선 연구 (Soil-Water Characteristic Curve of Sandy Soils Containing Biopolymer Solution)

  • 정종원
    • 한국지반환경공학회 논문집
    • /
    • 제19권10호
    • /
    • pp.21-26
    • /
    • 2018
  • 흙-습윤 특성곡선은 불포화토에서 물의 흐름, 다상유체에서의 상대투수계수, 그리고 흙의 강성 및 부피 변화를 이해하는데 필수적이다. 바이오폴리머는 미생물에 완전 분해가 가능한 자연에 무해한 친환경 물질이다. 따라서, 치토산, 폴리에틸렌 옥사이드, 잔탄검, 알지네이트염 및 폴리아크릴산 등과 같은 바이오폴리머가 지반복원, 지반성능향상 및 오일생산증진을 위해 연구되어왔다. 폴리아크릴산(polyacrylic acid)은 바이오폴리머의 일종으로, 유체의 흐름 특성 향상을 통하여 오일생산증진 및 지반복원 등의 분야에서 우수한 성능을 보여왔다. 따라서, 본 연구에서는 폴리아크릴산(polyacrylic acid)을 포함한 모래의 흙-습윤 특성곡선의 이해하기 위해서 실내시험을 수행하고, 이론적 모델의 매개변수 변화를 연구하였다. 그 결과, 폴리아크릴산(polyacrylic acid)의 농도가 증가함에 따라, 포화된 모래에 주입되는 공기의 주입 모세관압력이 증가함을 보이고, 높은 모세관압력에서의 잔류 함수비 역시 증가하고 있음을 보였다. 또한, 이론식 모델의 매개변수를 구하였으며, 이를 활용한 흙-습윤 특성곡선이 실내 실험 결과와 잘 일치하고 있음을 보였다. 따라서, 이론적 모델의 매개변수를 알고 있으면, 본 연구에서 활용된 폴리아크릴산(polyacrylic acid)이외의 바이오폴리머를 포함한 모래 지반의 흙-습윤 특성곡선이 예측이 가능함을 설명하였다.

실험견에서 Metoprolol 약리효과의 약동/력학적 검토 (Pharmacokinetic/Pharmacodynamic Analysis of Metoprolol in Dogs)

  • 오동진;장인진;이경훈;임동석;김형기;신상구;박찬웅;신재국
    • 대한약리학회지
    • /
    • 제31권2호
    • /
    • pp.251-259
    • /
    • 1995
  • Pharmacokinetics and pharmacodynamics of metoprolol, a selective beta-l blocker, were examined for 360 minutes after intravenous bolus administration of metoprolol to 6 dogs. Plasma concentration and excreted amount in the urine metoprolol were measured by liquid chromatography with fluorescence detection. PR interval and heart rate were measured by ECG monitoring. Blood pressure was monitored through intraarterial catheter in femoral artery and cardiac output by thermodilution method using Swan-Ganz catheter. To analyze the effect site concentration-response relationship, plasma concentration and pharmacological effects were simultaneously fitted to a two pharmacokinetic compartment linked to pharmacodynamic model with NONLIN program. Results are as follows. 1) The plasma concentration of metoprolol after intrvenous injection decreased biexponentially. The terminal half-life estimated was $1.33{\pm}0.40$ hours and the volume of distribution at steady state (Vdss) and the total body clearance were $1.04{\pm}0.4\;L/kg,\;6.55{\pm}2.21\;L/hr$, respectively. The central compartment volume of distribution and peripheral compartment volume of distribution were $0.35{\pm}0.14L/kg\;and\;0.69{\pm}0.34L/kg$. The renal clearance and intercompartment clearance were $0.53{\pm}0.25\;L/min\;and\;0.35{\pm}0.19\;L/min$. 2) Simulated biophase concentration-response curve shows hyperbolic relationship and the estimated concentration-effect relationship was best explained by Emax model when the prolongation of PR interval and the reduction of the heart rate were used as pharmacodynamic parameters. Emax and EC50 were estimated to be $26.3{\pm}4.7\;msec\;and\;88.8{\pm}82.3\;g/ml$ for PR interval, and $48.7{\pm}18.8\;beats/min\;and\;113.5{\pm}78.7\;ng/ml$ for heart rate, respectively. 3) The changes of cardiac output-effect site concentration relationship was best fitted by a linear model and the slope of the relationship was $0.005{\pm}0.003$. Diastolic blood pressure-effect site concentration relationship was also explained by the linear model and the slope of the relationship was $0.038{\pm}0.034$.

  • PDF