• 제목/요약/키워드: pressure tube

검색결과 2,124건 처리시간 0.028초

세관내 R-22와 R-410A의 응축 압력강하 (The Condensation Pressure Drop of R-22 and R-410A in Small Diameter Tube)

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제19권2호
    • /
    • pp.156-162
    • /
    • 2008
  • The condensation pressure drop for R-22 and R-410A flowing in a small diameter tube was investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and coolant flowing in the annulus. The test section consists of 1220 mm length with horizontal copper tube of 3.38 mm outer diameter and 1.77 mm inner diameter. The refrigerant mass fluxes ranged from 450 to $1050\;kg/m^2{\cdot}s$ and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main experimental results were summarized as follows : In the case of two-phase flow, the pressure drop increases with increasing mass flux and decreasing quality. The pressure drop of R-22 is slightly higher than that of R-410A for the same mass flux. Most of correlations proposed in the large diameter tube showed enormous deviations with experimental data.

삼차원 조도관의 압력손실 및 열전달 성능에 대한 실험적 연구 (An Experimental Study on the Pressure Drop and Heat Transfer Performance in Tubes with Three Dimensional Roughness)

  • 김내현
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.276-286
    • /
    • 1995
  • In this study, pressure drop and heat transfer coefficients were measured in tubes with three dimensional roughness. Dimples were made by rotating the saw-tooth shaped finning disc on the outer tube surface. Resultant dimple shape was oval. Friction and heat transfer tests were performed with a range of roughness variables-roughness height 'e', axial roughness pitch 'p', circumferential roughness pitch 'z'. Within the test range, tube with e=0.5mm, z=5mm, p=3mm performed best. The efficiency ratio(rati of the heat transfer improvement and the pressure drop increase) of the tube approached 1.0 at low Reynolds number, and it was higher than that of the two-dimensional roughess tube of the same roughness height. Test data were predicted by 'discrete element method'. Results show that discrete element method underpredicts the friction data by 2% to 32%, and overpredicts the heat transfer data by-12% to 113%.

  • PDF

가장 효율적인 음향 압축기의 튜브형상 (Tube Shape for Highly Efficient Sonic Compressor)

  • 전영두;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1455-1460
    • /
    • 2000
  • When a tube is oscillated at a resonant frequency, acoustic variables such as density, velocity, and pressure undergo very large perturbation, often described as nonlinear oscillation. In order to analyze these phenomena, nonlinear governing equation has been drived and solved numerically. Numerical simulations were accomplished to study the effect of the tube shape on the maximum pressure we can obtain. The tubes of cylindrical, conical, and cosine-shape, which have same volume and length, were investigated. Results show that the resonant frequency and patterns of pressure waves strongly depend on not only the tube shape but also the amplitude of driving acceleration. The degree of non-linearity of wave patterns was also measured by the newly defined nonlinear energy ratio of the pressure signals. It was found that the 1/2 cosine-shape tube is more suitable to induce high compression ratio than other shapes.

  • PDF

스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구 (Study of the performance characteristics of the Stirling type orifice pulse tube refrigerator)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.63-67
    • /
    • 2002
  • In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.

중수로 압력관의 크리프 처짐 해석 기법 및 프로그램 개발 (Development of Creep Deflection Analysis Method and Program for CANDU Pressure Tube)

  • 심도준;허남수;박보규;장윤석;김윤재;김영진;정현규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.66-71
    • /
    • 2004
  • Estimation of the CANDU pressure tube deflection is important since the deflection may cause significant structural failure due to hydrogen diffusion and blister. However, there is no appropriate engineering model to estimate it exactly. The purpose of this paper is to propose a new analysis method and program to resolve this issue. For development of proper analysis method, a series of finite element analyses has been carried under elastic-creep condition. In addition, for effective estimation of the creep deflection, an analysis program named PC-DAS was developed based on the proposed method. Comparison of simple case study results with corresponding reference ones showed good agreement. Therefore, the proposed method and program can be utilized as one of valuable toolkit for integrity assessment of CANDU pressure tube.

  • PDF

원형 미소 채널 내 계면장력이 Plug flow 압력강하에 미치는 영향에 관한 선행 연구 (Effect of Interfacial Tensions on Pressure Drop of Two-Phase Plug Flow in Round Mini-channels -A Preliminary Investigation-)

  • 이치영;이상용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1882-1887
    • /
    • 2007
  • In the present experimental study, the effect of interfacial tensions on pressure drop of air-water two-phase flow in round mini-channels was investigated. A glass (highly wettable) tube and a Teflon (poorly wettable) tube, both in 350 mm length but 1.8 mm and 1.59 mm in inner diameters each, were used for the tests. All the experiments were performed only in the plug flow regime, confirmed by visualization. In the glass tube, the gas plugs were surrounded by the liquid film along the inner periphery. On the other hand, the inner wall remained dry at the gas portion in the Teflon tube. The pressure drop of the plug flow in the Teflon tube without the liquid film) appeared much larger than in the glass tube (with the liquid film) due to dissipation of energy by movement of the wetting lines. In this paper, various correlations on the two-phase pressure drop of plug flows were compared and a modified correlation was proposed, taking account of the surface wettability.

  • PDF

나노입자를 포함한 자연냉매의 마이크로 휜관 응축 열전달 특성 (Condensing Heat Transfer of Natural Refrigerants with Nanoparticles in Enhanced Tube)

  • 이호생
    • 동력기계공학회지
    • /
    • 제12권3호
    • /
    • pp.19-25
    • /
    • 2008
  • This paper deals with the heat transfer and pressure drop characteristics of R-290 (Propane), R-600a (Iso-butane) and R-1270 (Propylene) as an environment friendly refrigerant and R-22 as a HCFC's refrigerant for condensing. The test section is a horizontal double pipe heat exchanger. Condensing heat transfer and pressure drop measurements were Peformed for 12.70 mm micro-fin tube and compared with the results in smooth tube. The local condensing heat transfer coefficients of hydrocarbon refrigerants were superior to those of R-22 and the maximum increasing rate of heat transfer coefficient was found in R-600a. The average condensing heat transfer coefficients in hydrocarbon refrigerants showed 20 to 28% higher values than those of R-22. Hydrocarbon refrigerants have a higher pressure drop than that of R-22 with respect to refrigerant qualify and mass flux. Also, the condensing heat transfer coefficient and pressure drop of working fluids in smooth and micro-fin tube were compared. The heat transfer enhancement factor (EF) between smooth and micro-fin tube varied from 2.2 to 2.6 in all experimental conditions.

  • PDF

액체금속로 중간열교환기 관다발에서의 튜브배열과 경사각도가 압력강하에 미치는 영향 (The Effects of Tube Arrangement and Inclination on the Pressure Drop in Tube Bundles of Intermediate Beat Exchanger in Liquid Meta Reactor)

  • 남호윤;김종만;최종현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.659-662
    • /
    • 2002
  • The present paper presents the experimental results for pressure drop in inclined tube bundles located in a rectangular duct. Measurements are made for pressure drop in triangular and rotated triangular tube arrays having P/d ratio of 1.6 and inclination angles of 30,45,60 and 90 degrees. The Reynolds number based on the free stream velocity and tube diameter ranges from $8{\times}10^2\;to\;6.3{\times}10^{4}$. The experimental results show that the magnitude of dimensionless pressure drop decreases significantly when the inclined angle is less than 45 degree. The measured data are compared with two existing correlations available in the literatures. The ESDU correlation agrees well with the present data far the triangular arrays. But some discrepancies are observed for the rotated triangular arrays when the inclined angles are 30 and 45 degrees. The Idel'chik correlation generally agrees well with the measured data for the rotated triangular arrays except for the inclined angle of 30 degree. The Idel'chik correlation needs modification for the triangular arrays. The modified Idel'chik correlation agrees well with the measured data within $10{\%}$. It is found that the present measured data can be applied to the evaluation and modification of previous correlations.

  • PDF

튜브열차 구조물의 진공 펌프 용량에 관한 파라메타 연구 (Parametric Study on the Capacity of Vacuum Pump for Tube Structure)

  • 남성원
    • 한국철도학회논문집
    • /
    • 제13권5호
    • /
    • pp.516-520
    • /
    • 2010
  • 튜브 구조물의 압력을 대기압 이하로 유지하는데에 사용될 진공 펌프의 용량을 설정하기 위한 파라메타 연구를 수행하였다. 최근 철도 기술 연구자들은 초고속 수송 시스템의 하나인 튜브 열차 시스템에 관심을 가지게 되었다. 초고속을 달성하기 위하여 튜브 내부를 저압으로 유지할 필요가 있는데, 저압에서는 공기 저항이 극단적으로 줄어들기 때문이다. 진공 펌프 시스템은 튜브 내부를 저압으로 만들고, 누설을 보충하는 역할을 한다. 일련의 연구결과, 다양한 파라메타에 대한 진공 펌프의 용량을 구하였다. 이 결과들은 공기 저항 저감 효과를 분석하는데에 적용될 것이다.

측정 데이터 기반 중수로 압력관 직경평가 방법론 개발 (Diameter Evaluation for PHWR Pressure Tube Based on the Measured Data)

  • 정종엽
    • 한국압력기기공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.27-35
    • /
    • 2023
  • Pressure tubes are the main components of PHWR core and serve as the pressure boundary of the primary heat transport system. However, because pressure tubes have changed their geometrical dimensions under the severe operating conditions of high temperature, high pressure and neutron irradiation according to the increase of operation time, all dimensional changes should be predicted to ensure that dimensions remain within the allowable design ranges during the operation. Among the deformations, the diameter expansion due to creep leads to the increase of bypass flow which may not contribute to the fuel cooling, the decrease of critical channel power and finally the deration of the power to maintain the operational safety margin. This study is focused on the modeling of the expansion of the pressure tube diameter based on the operating conditions and measured diameter data. The pressure tube diameter expansion was modeled using the neutron flux and temperature distributions of each fuel channel and each fuel bundle as well as the measured diameter data. Although the basic concept of the current modeling approach is simple, the diameter prediction results using the developed methodology showed very good agreement with the real data, compared to the existing methodology.