• 제목/요약/키워드: pressure time

검색결과 7,996건 처리시간 0.039초

동-텅스텐 소결합금(Cu-W)과 동(Cu)의 마찰용접에서 마찰압력이 접합강도와 파단특성에 미치는 영향 (Effects of Friction Pressure on Bonding Strength and a Characteristic of Fracture in Friction Welding of Cu to Cu-W Sintered Alloy)

  • 강성보;민택기
    • Journal of Welding and Joining
    • /
    • 제15권4호
    • /
    • pp.90-98
    • /
    • 1997
  • A copper-tungsten sintered alloy(Cu-W) has been friction welded to a tough pitch copper in order to investigate the effect of friction pressure on bonding strength and a charicteristic of fracture. The tensile strength of the friction welded joint was increased up to 90% of the Cu base metal under the condition of friction time 1.2 sec, friction pressure 4.5kgf/$\textrm{mm}^2$ and upset pressure 10kgf/$\textrm{mm}^2$. From the results of fracture surface analysis, the increase of friction pressure could remarkably decrease the force and the time to be normally acted on weld interface. The W particles which were included in the plastic zone of Cu side could induce fracture adjacent to the weld interface because their existance in Cu induces a decrease in available section area and an increase in notch effect. Therefore, the tensile strength was decreased at high friction pressure (6kgf/$\textrm{mm}^2$) because the destruction of W was increased by an increase in mechanical force and crack was formed at weld interface.

  • PDF

개선된 계단 배기 방법을 이용한 혈압 측정 (Blood Pressure Measurement using the Modified Step-wise Deflation Method)

  • 오홍식;이종실;지영준;김인영
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권5호
    • /
    • pp.351-358
    • /
    • 2010
  • In the automatic non-invasive blood pressure measurement device, the oscillometric method iswidely used. In the oscillometric method, the step-wise deflation has the advantage of the robustness for the motion artifacts than the linear deflation method. But it has the disadvantage of its longer measurement time because we need to detect two or more pulses in a certain cuff pressure step. In this study, we suggest the modified step-wise deflation method to overcome this limitation while maintaining the general concept of step-wise deflation. Using one valid pulse in each step and the deflating valve control during the diastolic period, the measurement time could be reduced. In order to verify the accuracy of the proposed algorithm, we compared the blood pressure values from the suggested method and the blood pressure values from the conventional auscultation method. The mean and standard deviation were -0.50${\pm}$5.3mmHg and 2.08${\pm}$4.75mmHg, for systolic and diastolic blood pressure respectively. The measurement time can be reduced up to the half of conventional step-wise deflation method.

20대 성인의 보행 후 휴식시간에 따른 진동식 자동혈압계와 수은혈압계의 안정혈압 도달 시점 (Time for Young Adults to Reach Resting Blood Pressure after Walking as measured by an Automatic and a Mercury Sphygmomanometer)

  • 최민정;송경애
    • 기본간호학회지
    • /
    • 제21권4호
    • /
    • pp.370-379
    • /
    • 2014
  • Purpose: The purpose of this study was to identify the time for young adults to reach resting blood pressure after walking as measured by an automatic and a mercury sphygmomanometer. Methods: Participants were 33 nursing students in their 20s. Blood pressure after walking was measured every minute on both arms simultaneously for a total of 6 times after walking for 12 minutes on a treadmill at ratings of perceived exertion (RPE) of 11. Data were analyzed using paired t-test, Bland-Altman plots and repeated measures ANOVA. Results: Systolic blood pressure after walking was the same as measurements corresponding to resting blood pressure after 3 minutes of resting if measured with the automatic sphygmomanometer and 4 minutes of resting if measured with the mercury sphygmomanometer. Conclusions: In order to measure the resting blood pressure for healthy young adults who performed low-density walking for 12 minutes on flat land, the measurement needs to be made after a resting time of at least 3 minutes in the case of an automatic sphygmomanometer and 4 minutes in the case of a mercury sphygmomanometer.

Flexible Flat Cable 생산성 향상을 위한 가압용 히팅롤러의 온도제어개선 (Temperature Control Improvement of Pressure Heating Roller for Flexible Flat Cable Production)

  • 김재학;이호중;전경진
    • 한국정밀공학회지
    • /
    • 제22권7호
    • /
    • pp.155-163
    • /
    • 2005
  • Pressure heating rollers with temperature control were mounted to a flat cable laminating machine (FCLM). Pressure heating rollers should be heated up to the setting temperature $(175^{\circ}C)$ and kept on to producing good quality flexible flat cables (FFC). Existing Pressure heating rollers took more than 70minutes to the setting temperature and did not keep on the setting temperature in production. Temperature controller, electric power controller, material and diameter of rollers and heat capacities were changed to improve the temperature control of the pressure heat rollers for better production of the FFC. Thus, the reaching time to the setting temperature (RT), temperature stability time (TST) and temperature hunting (TH) were measured and compared with the existing pressure rollers case. The RT of A roller was shortened by 50minutes, and B roller was shortened by 15minutes. The TST of A roller was shortened by 13minutes, and B roller was shortened by 15minutes. The THs of both A and B rollers were settled up to ${\pm}5^{\circ}C$. Finally, the productivity of the FCLM and the quality of the FFC were increased.

저압 에어포그 시스템을 설치한 온실의 냉방효율 (Cooling Efficiency of Low Pressure Compressed Air Fogging System in Naturally Ventilated Greenhouses)

  • 남상운;김영식;성인모;고기혁
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.49-55
    • /
    • 2012
  • In order to derive the efficient utilization of low pressure compressed air fogging system, cooling efficiencies with control types were analyzed through cooling experiments in tomato greenhouses. The control types were set up with temperature control, humidity control, temperature and humidity control, and time control. It showed that the cooling effects were 0.7 to $3.3^{\circ}C$ on average and maximum of 4.3 to $7.0^{\circ}C$, the humidification effects were 3.5 to 13.5 % on average and maximum of 14.3 to 24.4 %. Both the cooling and humidification effect were the highest in the time control method. The cooling efficiency of the air fogging system was not high with 8.3 to 27.3 % on average. However, the cooling efficiency of 24.6 to 27.3 % which appears from the time control is similar to the cooling efficiency of high pressure fogging system experimented in Japan. The air fogging system is operated by low pressure, but its efficiency is similar to high pressure. We think because it uses compressed air. From this point of view, we suggest that the air fogging system can get the cooling efficiency of similar levels to that of high pressure fogging system and it will have an advantage from clogging problem of nozzle etc.

진공의 압력과 시간을 달리할 때 시멘트시험편의 유효공극률 변화 (Effective Porosity Variation of Cement Samples According to Vacuum Pressure and Time)

  • 이상규;이태종;김형찬
    • 지구물리와물리탐사
    • /
    • 제15권4호
    • /
    • pp.163-176
    • /
    • 2012
  • 진공 수포화 과정에서 진공시간과 진공압력을 달리하면서 진공시간 및 압력이 유효공극률 산정에 미치는 영향을 살펴보았다. 시멘트와 모래의 무게비가 1대1인 3개의 시멘트 시험편과 100% 시멘트 모르타르 3개 등 총 6개 시험편을 이용하여 진공 압력을 2, 4, 6, 8, 10 torr, 진공시간을 20, 40, 60, 80, 100분으로 달리하며 측정되는 유효공극률을 비교하였다. 평균 약 25%와 40%로 비교적 큰 유효공극률을 갖는 시멘트 시험편에 대하여 진공압력이 10, 6, 2 torr 일 때 진공시간이 100 ~ 20 분으로 변화하는 3개 시험군 끼리의 결과를 비교하면, 절대편차의 평균값이 0.6%에서부터 0.5%, 0.2%로 작게 나타났다. 진공시간이 100, 60, 20분일 때 진공압력을 각각 2 ~ 10 torr로 변화시키면서 수행한 실험군 끼리의 유효공극률을 비교해도 진공시간이 짧아지면 절대편차의 평균값이 커지는 경향이 있었다. 이로부터 진공압력/진공시간에 관한 국제암반역학회(ISRM) 표준(제안)시험법의 "6 torr 이하/1시간 이상"의 단서로 유추할 수 있었다. 동일한 진공압력에서 진공시간이 20분씩 줄어들 때의 효과와 동일한 진공시간일 때 진공압력이 2 torr씩 낮아질 때의 효과를 정성적으로 밖에 확인할 수 없었는데 그 이유로 습식진공으로 포화된 시험편 내 수분이 $105^{\circ}C$ 오븐 내에서의 건조과정 후에도 완전히 건조되지 않아서 시험편의 초기 함수정도를 동일하게 할 수 없기 때문임을 밝혔다.

디젤 분무의 분무 형태와 입경 분포에 관한 실험적 연구 (An experimental study on spray pattern and droplet size distribution of diesel spray)

  • 지요한;이종화;김응서
    • 오토저널
    • /
    • 제14권3호
    • /
    • pp.102-108
    • /
    • 1992
  • To clarify the structure of a diesel spray, a transient non-evaporating diesel spray injected under different ambient pressure and different injection pressure was studied. Spray tip penet- ration and spray angle were measured by taking the high speed shadowgraph of spray and Sauter mean Diameter(SMD) was also measured by light scattering technique at different positions along the spray axis and at different time from the start of injection. The effects of the operating parameters on the spray shape and SMD were investigated. By increasing the injection pressure, the spray tip penetration and the spray angle increased and the change of the ambient pressure also resulted in the considerable change in the shape of the spray. The analysis of SMD measurement showed that the atomization is a process that continues in sp- ace and time. As the injection pressure increases SMD decreases rapidly and with the increa- se of the ambient pressure the atomization process ends faster than the lower ambient press- ure and at lower pressure the atomization process continues to much farther downstream and far afterward.

  • PDF

메탄올 액적 화염의 음향파 가진에 의한 재점화 (Reignition of Methanol Droplet Flames Under Acoustic Pressure Oscillation)

  • 김홍집;손채훈;정석호
    • 대한기계학회논문집B
    • /
    • 제23권1호
    • /
    • pp.114-122
    • /
    • 1999
  • Reignition as special cases of acoustic pressure responses of flame are numerically studied by employing methanol droplet flame as a laminar flamelet. Quasi-steady flame responses occur in the range of small amplitude, low frequency oscillation. Reignition phenomena can occur when, by increasing the frequency of large amplitude acoustic pressure, the magnitude of characteristic acoustic time is the same order of that of characteristic reaction time of flames. And more increasing of amplitude of acoustic pressure induces the direct extinction of flame. Flame can sustain its own intensity even under the steady extinction temperature in case of high frequency acoustic oscillation, and this tendency is remarkable with increasing frequency. Reignition regime with respect to amplitude and frequency of acoustic pressure doesn't exist in low frequency($10^2$ Hz, in this study), but broadens with frequency of acoustic pressure.

자기충전 콘크리트의 거푸집 압력 예측 모델에 대한 검증 실험 (Experiment for Verification of Prediction Model for see Formwork Pressure)

  • 권승희;풍궉지;김재홍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.217-218
    • /
    • 2009
  • 기존에 개발되었던 자기충전 콘크리트의 거푸집 예측 모델에 대해 실험을 통한 검증이 이루어졌다. 실험실에서 거푸집 압력을 모사할 수 있는 실험 장비를 제작하였으며, 자기충전 콘크리트에 대해 실험을 수행하였다. 실험결과로부터 각각의 재료에 대해 모델 교정(Calibration)을 수행하였고, 일반적인 타설 조건을 고려한 거푸집 압력 측정 실험과 교정된 모델로 부터 얻은 해석결과를 비교해 보았다. 모델을 구성하는 파라미터는 재하시간에 따라 특정한 경향을 나타내었으며, 해석 값이 측정된 거푸집 압력의 시간에 따른 변화를 정확히 모사하였다.

  • PDF

High Precision Pressure Control of a Pneumatic Chamber using a Hybrid Fuzzy PID Controller

  • Liu, Hao;Lee, Jae-Cheon;Li, Bao-Ren
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권3호
    • /
    • pp.8-13
    • /
    • 2007
  • A hybrid fuzzy PID controller for a pneumatic chamber is proposed in this paper. First, a mathematical model of a pneumatic pressure servocontrol system was developed where separate implementations of a PID controller and a fuzzy controller were made. The experimental results using a step input signal revealed that the PID controller accurately controlled the steady-state pressure but did not robustly handle parameter variations in the system while the fuzzy controller provided a fast rise time and low overshoot of the pressure in the system. In order to attain the advantages of both the fuzzy and PID controllers, a hybrid control scheme was developed. The experimental results show that the hybrid fuzzy PID controller proposed in this study does indeed possess the advantages of both PID and fuzzy controllers. Hence, it can be concluded that the hybrid fuzzy PID controller is suited for high-precision control of pressure in a pneumatic chamber.