Temperature Control Improvement of Pressure Heating Roller for Flexible Flat Cable Production

Flexible Flat Cable 생산성 향상을 위한 가압용 히팅롤러의 온도제어개선

  • Published : 2005.07.01

Abstract

Pressure heating rollers with temperature control were mounted to a flat cable laminating machine (FCLM). Pressure heating rollers should be heated up to the setting temperature $(175^{\circ}C)$ and kept on to producing good quality flexible flat cables (FFC). Existing Pressure heating rollers took more than 70minutes to the setting temperature and did not keep on the setting temperature in production. Temperature controller, electric power controller, material and diameter of rollers and heat capacities were changed to improve the temperature control of the pressure heat rollers for better production of the FFC. Thus, the reaching time to the setting temperature (RT), temperature stability time (TST) and temperature hunting (TH) were measured and compared with the existing pressure rollers case. The RT of A roller was shortened by 50minutes, and B roller was shortened by 15minutes. The TST of A roller was shortened by 13minutes, and B roller was shortened by 15minutes. The THs of both A and B rollers were settled up to ${\pm}5^{\circ}C$. Finally, the productivity of the FCLM and the quality of the FFC were increased.

Keywords

References

  1. Omron Industrial Automation, '온도조절기 종합 카달로그,' OMRON INDUSTRIAL AUTOMATION, pp. 전 34-전 35, 2004
  2. Kreith, F., Bohn, M. S., 'PRINCIPLES OF HEAT TRANSFER,' SCIENCE & TECHNILOGY, pp. 4, 2002
  3. ASM Handbook Committee, 'ASM HANDBOOK EIGHTH EDITION (properties and selection),' ASM, pp. 55, 1977
  4. Yoon, Y. K., Kim, G. K., Yoon, H. S., 'A Study of the Mechanical Properties of Patch-Bonded and Riveted Repairs on Cracked A16061-T6 Alloy Structure,' International Journal of the Korea Society of Precision Engineering, Vol. 001. No. 002, 2000
  5. Rilley, Sturges, Morris, 'Mechanics of Materials,' SciTech, pp. 1, 2000
  6. ASM International, 'ASM Handbook Volume I,' ASM, pp. 197-199, 1990
  7. ASTM, '1995 ANNUAL BOOK OF ASTM STANDARDS SECTION 2,' ASTM, pp. 294, 1995
  8. Shin, Y. G., Ko, Y. H., Kim, Y. I., Jeong, K. H., 'Optimal PID control of an electric heater,' The Society of Air Conditioning and Refrigerating Engineers of Korea, Proceeding of the SAREK 1999 Summer Annual Conference, pp. 1026-1030, 1999
  9. Chang, Y. J., Park, Y. C., Chang, K. S., 'A Electric Heater Control for the Supply Air Temperature Control in PEM,' The Society of Air Conditioning and Refrigerating Engineers of Korea Proceeding of the SAREK 2004 Summer Annual Conference, pp. 1337-1342, 2000