• Title/Summary/Keyword: pressure test

Search Result 7,882, Processing Time 0.036 seconds

Study on the Design, Manufacture, and Pressure Test of a Pressure Vessel Model (내압용기 모형의 설계, 제작 및 압력시험에 관한 연구)

  • Joung, Tae-Hwan;Lee, Jae-Hwan;Lee, Chong-Moo;Hykudome, Tadahiro;Sammut, Karl;Nho, In-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.6
    • /
    • pp.101-106
    • /
    • 2007
  • In this paper, the authors demonstrate a new idea to take the place of the real pressure vessel test, which should be carried out in a high pressure experiment unit before the real sea trial test. The idea is to make a pressure vessel model as a replica of the real pressure vessel test, which can reduce the cost of making a pressure vessel and large pressure experiment unit. The pressure vessel model was designedbased on linear-elastic, buckling equations and Finite Element Analysis. The manufactured pressure vessel model was investigated and monitored while the pressure test was being conducted. After the test, the result and the validity of the pressure vessel model as a replica of the real pressure vessel test was studied.

Analysis of Consolidation Characteristics of Soft Clay Based on Constant Pressure Ratio Consolidation Test (일정 압력비 압밀시험을 이용한 연약점토의 압밀특성 분석)

  • 김훈규;정두회
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.455-462
    • /
    • 2002
  • There exist several kinds of continuous consolidation tests to analyze the consolidation behavior of soft clay. The constant rate of strain (CRS) test has been adopted as a standard method by several countries, and some researches also have been peformed by domestic researchers. Among those, the constant pressure ratio (CPR) test is peformed with the constant ratio of excess porewater pressure to vertical effective stress. The test has the advantage of considerable reduction of duration time. In the study, the consolidation characteristics are analyzed by performing the CPR test as validate the pressure ratio with undisturbed soft clay and remolded clay, Also, results of the standard consolidation test and CRS test are compared to verify the CPR test can be employed for practical use. As a result, effects of variation of the pressure ratio on consolidation parameter are similar to the strain rate in the CRS test. Therefore, the test can be used to analyze the consolidation behavior of soft clay But the test have some problems such as expensive cost of equipment and highly skilled workmanship.

  • PDF

Natural wind impact analysis of transiting test method to measure wind pressure coefficients

  • Liu, Lulu;Li, Shengli;Guo, Pan;Wang, Xidong
    • Wind and Structures
    • /
    • v.30 no.2
    • /
    • pp.199-210
    • /
    • 2020
  • Building wind pressure coefficient transiting test is a new method to test the building wind pressure coefficient by using the wind generated by a moving vehicle, which is susceptible to natural wind and other factors. In this paper, the Commonwealth Advisory Aeronautical Research Council standard model with a scale ratio of 1:300 is used as the test object, and the wind pressure coefficient transiting test is repeated under different natural wind conditions to study the influence of natural wind. Natural wind is measured by an ultrasonic anemometer at a fixed location. All building wind pressure coefficient transiting tests meet the test conditions, and the vehicle's driving speed is 72 km/h. The mean wind pressure coefficient, the fluctuating wind pressure coefficient, and the correlation coefficient of wind pressure are used to describe the influence of natural wind on the building wind pressure coefficient transiting test qualitatively and quantitatively. Some rules, which can also help subsequent transiting tests, are also summarized.

Development of Automation System of Water-Hydraulic and Leakage Test for Pressure Vessel (압력용기 수압 및 기밀시험 자동화 시스템 개발)

  • 이원희;김동수;이승현;김광영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1672-1675
    • /
    • 2003
  • In this study, we developed full automation test system for pressure vessel. This pressure vessel containing oxygen, nitrogen and carbon is widely used in industrial field. The test items of pressure vessel are divided into three branches which is weight measurement, water-hydraulic, and leakage test. After leakage test is completed, cleaning and dry progress is carried out. And control system is consist of three controller which is PLC, monitoring system and database system. PLC is control all of system. Monitoring system measures weight, pressure, flow etc and display to all conditions. Database system stores tested data. we design system to control all test modules in communication by a second period with three control modules. Finally, we verified this system by field test.

  • PDF

Burst Test and Finite Element Analysis for Failure Pressure Evaluation of Nuclear Power Plant Pipes (원전 배관 손상압력 평가를 위한 파열시험 및 유한요소해석)

  • Yoon, Min Soo;Kim, Sung Hwan;Kim, Taesoon
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.144-149
    • /
    • 2015
  • This study aims to quantitatively evaluate failure pressure of wall-thinned elbow under combined load along with internal pressure, by conducting real-scale burst test and finite element analysis together. For quantitative evaluation, failure pressure data was extracted from the real-scale burst test first, and then finite element analysis was carried out to compare with the test result. For the test, the wall-thinning defect of the extrados or intrados inside the center of 90-degree elbow was considered and the loading modes to open or close the specimen maintaining a certain load or displacement were applied. Internal pressure was applied until failure occurred. As a result, when the bending load was applied under the load control condition, the intrados of the defect was more affected by failure pressure than the extrados, and the opening mode was more vulnerable to failure pressure than the closing mode. When the bending load was applied under the displacement control, it was hardly affected by failure pressure though it was slightly different from the defect position. The result of the finite element analysis showed a similar aspect with the test. Moreover, when major factors such as material properties and pipeline thickness were calibrated to accurate values, the analytical results was more similar to the test results.

Pressure analysis in grouting and water pressure test to achieving optimal pressure

  • Amnieh, Hassan Bakhshandeh;Masoudi, Majid;Kolahchi, Reza
    • Geomechanics and Engineering
    • /
    • v.13 no.4
    • /
    • pp.685-699
    • /
    • 2017
  • In order to determine the rate of penetrability, water pressure test is used before the grouting. One of the parameters which have the highest effect is pressure. Mathematical modeling is used for the first time in this study to determine the optimum pressure. Thus, the joints that exist in the rock mass are simulated using cylindrical shell model. The joint surroundings are also modeled through Pasternak environment. In order to validate the modeling, pressure values obtained by the model were used in the sites of Seymareh and Aghbolagh dams and the relative error rates were measured considering the differences between calculated and actual pressures recorded in these operations. In water pressure test, in Seymareh dam, the error values were equal to 4.75, 3.93, 4.8 percent and in the Aghbolagh dam, were 22.43, 5.22, 2.6 percent and in grouting operation in Seymareh dam were equal to 9.09, 32.50, 21.98, 5.57, 29.61 percent and in the Aghbolagh dam were 2.96, 5.40, 4.32 percent. Due to differences in rheological properties of water and grout and based on the overall results, modeling in water pressure test is more accurate than grouting and this error in water pressure test is 7.28 percent and in grouting is 13.92 percent.

Sensitivity Analysis of Initial Pressure and Upper Control Limit on the Pressure Decay Test for Membrane Integrity Evaluation (압력손실시험을 이용한 막 완결성 평가에서 초기압력 및 UCL 도출인자 민감도 분석)

  • Lee, Joohee;Hong, Seungkwan;Hur, Hyunchul;Lee, Kwangjae;Choi, Youngjune
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.793-800
    • /
    • 2008
  • Recently domestic drinking water industry has recognized membrane-based technology as a promising alternative for water treatment. To ensure successful application of membrane processes, the integrity of membrane systems should be maintained. According to US EPA guidance, the pressure decay test based on the bubble point theory is recommended to detect any membrane defection of which size is close to the smallest diameter of Cryptosporidium oocysts, $3{\mu}m$. Proper implementation of the pressure decay test is greatly affected by initial test pressure, and the interpretation of the test results is associated with upper control limit. This study is conducted to investigate various factors affecting determination of initial test prtessure and upper control limit, including membrane-based parameters such as pore shape correction factor, surface tension and contact angle, and system-based parameters, such as volumetric concentration factor and total volume of system. In this paper, three different hollow fibers were used to perform the pressure decay test. With identical initial test pressure applied, their pressure decay tendency were different from each other. This finding can be explained by the micro-structure disparity of those membranes which is verified by FESEM images of those membranes. More specifically, FESEM images revealed that three hollow fibers have asymmetry, deep finger, shallow finger pore shape, respectively. In addition, sensitivity analysis was conducted on five parameters mentioned above to elucidate their relation to determination of initial test pressure and upper control limit. In case of initial pressure calculation, the pore shape correction factor has the highest value of sensitivity. For upper control limit determination, system factors have greater impact compared to membrane-based parameters.

Development of Blood Pressure Simulator for Test of the Arm-type Automatic Blood Pressure Monitor (팔뚝형 자동혈압계 평가용 혈압 시뮬레이터 개발)

  • Kim, S.H.;Yun, S.U.;Cho, M.H.;Lee, S.J.;Lim, M.H.;Seo, S.Y.;Jeon, G.R.
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.239-246
    • /
    • 2015
  • Blood pressure is possible to diagnose a disease associated with blood pressure and judgment the current health of patients. Automatic blood pressure monitor capable of measuring a blood pressure easily in hospital and at home have become spread. In this study, we developed the blood pressure simulator (BPS) that can test the arm-type automatic blood pressure monitor that is commonly used in hospital. BPS is to produce a pressure similar to the pressure wave generated in the human blood using a servo disk motor. Then, using the silicon tube, it implements the situations such as human blood vessels, and to output the generated pressure waveform. Simply the BPS's phantom put on the cuff and it is able to simulate blood pressure. So anyone can quickly test the blood pressure monitor within one minute and it is possible to shorten the test time required for the automatic blood pressure monitor. In Performance test, the trends and the standard deviation of the values measured in the BPS is similar to the value of the measured pressure from people with normal blood pressure. Thus, the development BPS showed a possibility of taking into account the actual blood pressure measurement environment simulator.

A study on the Pressure Test of the Glass Window for High Speed Train (고속철도차량용 창문유리의 압력시험에 관한 연구)

  • Chang, Dae-Sung;Yi, Won
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.5
    • /
    • pp.391-397
    • /
    • 2011
  • In this paper, the pressure endurance test of passenger train's glass window which was developed for next high speed train was studied. At first, pressure test equipment which will be able to generate the maximum pressure same as crossing case between two trainsets in the tunnel was developed. Afterwards the pressure test and evaluation that are based on NFF31-314 were carried out and studied.

The Design, Structural Analysis and High Pressure Chamber Test of a Thick Pressure Cylinder for 2000 m Water Depth (수심 2000m 용 두꺼운 내압용기의 설계, 구조해석과 내압시험)

  • Choi, Hyeuk-Jin;Lee, Jae-Hwan;Kim, Jin-Min;Lee, Seung-Guk;Maring, Kothilngam
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.2
    • /
    • pp.144-153
    • /
    • 2016
  • This paper aims to demonstrate the design, structure analysis, and hydrostatic pressure test of the cylinder used in 2000m water depth. The cylinder was designed in accordance with ASME pressure vessel design rule. The 1.5 times safety factor required by the general rule was applied to the design of the cylinder, because ASME rule is so excessive that it is not proper to apply to the hydrostatic pressure test. The finite element analysis was conducted for the cylinder. The cylinder was produced according to the design. The hydrostatic pressure test was conducted at the hyperbaric chamber in KRISO. The results of finite element analysis(FEM) and those of the hydrostatic pressure test were almost the same, which showed that the design was exact and reliable.