• Title/Summary/Keyword: pressure piping

Search Result 669, Processing Time 0.027 seconds

Time-Frequency Analysis of Lamb wave mode (램파모드의 시간-주파수 해석)

  • 박익근;안형근
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.133-140
    • /
    • 2001
  • Recently, to assure the integrity of a structural components such as piping pressure vessels and thinning structure, Lamb wave inspection technique has been used in material evaluation. It is very important to select the optimal Lamb wave mode and to analyze the signal accurately because of its unique dispersion properties grnerating several modes within the speci-men. It this study, the feasibility of material evaluation applications using wavelet analysis of Lamb wave has been veir-fied experimentally. These results show as follows; 1)dispersion characteristic of each mode in dispersion curve is demon-strated that A0 mode propagating material surface is useful mode having the lest energy loss and not sensitive to surface condition. 2) it can be detected even the micro defect ($1\times2mm$) fabricated in ultrasonic probe flaw distance (290mm) to axis direction. 3) the wavelet transform which is called "time-frequency analysis" shows the Lamb wave propagation due to the change of materials characterization can be evaluated at each frequency and experimental group velocity of Lamb wave agrees quite well with that of simulated dispersion curve.ion curve.

  • PDF

Identification on a Local Wall Thinning by Flow Acceleration Corrosion Inside Tee of Carbon Steel Pipe (탄소강 배관 티에서의 유동가속부식으로 인한 감육 현상 규명)

  • Kim, Kyung-Hoon;Lee, Sang-Kyu;Kang, Deok-Won
    • Journal of ILASS-Korea
    • /
    • v.16 no.2
    • /
    • pp.82-89
    • /
    • 2011
  • When pipe components made of carbon steel in nuclear, fossil, and industry plants are exposed to flowing fluid, wall thinning caused by FAC(flow accelerated corrosion) can be generated and eventually ruptured at the position of pressure boundary. The aim of this study is to identify the locations at which local wall thinning occurs and to determine the turbulence coefficient related to local wall thinning. Experiment and numerical analyses for the tee sections of down scaled piping components were performed and the results were compared. In particular, flow visualization experiment which was used alkali metallic salt was performed to find actual location of local wall thinning inside tee components. In order to determine the relationship between turbulence coefficients and local wall thinning, numerical analyses were performed for tee components in the main feedwater systems. The turbulence coefficients based on the numerical analyses were compared with the local wall thinning based on the measured data. From the comparison of the results, the vertical flow velocity component(Vr) flowing to the wall after separating in the wall due to the geometrical configuration and colliding with the wall directly at an angle of some degree was analogous to the configuration of local wall thinning.

Time History Analysis of Surge Line Considering PVRC Damping (PVRC 감쇠를 고려한 밀림관의 시간이력해석)

  • Kim Tae-Hyung;Jheon Jang-Hwan;Kim Jong-Min;Yoon Ki-Seuk;Kim In-Yong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.1025-1032
    • /
    • 2006
  • The PVRC(Pressure Vessel Research Council) damping is for the response spectrum analysis of the piping system. In this study, the possibility to apply it to the time history analysis is evaluated to reduce the higher conservatism for the structural integrity. The evaluation was performed for the surge line connecting the pressurizer to the hot-leg, and the whole mode includes the RCS and the building structures with the surge line. The analyses were performed using ANSYS code. The first modal analysis shows the modes of the surge line are isolated from those of the other structures. The composite modal damping was calculated with PVRC damping for the surge line and RG 1.60 damping for the other structures by using ANSYS routines. Of the calculated composite modal damping values, the composite modal damping values related to the modes of the surge line were replaced with the PVRC damping values with respect to its frequencies. With this replacement, the composite modal damping values of the other structures were not changed. Based on this decouple characteristics, the time history analyses for the seismic events with PVRC damping for the surge line were performed. And the results show the resultant loads can be reduced by up to 50%.

  • PDF

Conceptual Design of Passive Containment Cooling System for Concrete Containment

  • Lee, Seong-Wook;Baek, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.358-363
    • /
    • 1995
  • A study on passive cooling systems for concrete containment of advanced pressurized water reactors has been performed. The proposed passive containment cooling system (PCCS) consist of (1) condenser units located inside containment, (2) a steam condensing pool outside containment at higher elevation, and (3) downcommer/riser piping systems which provide coolant flow paths. During an accident causing high containment pressure and temperature, the steam/air mixture in containment is condensed on the outer surface of condenser tubes transferring the heat to coolant flowing inside tubes. The coolant transfers the heat to the steam condensing pool via natural circulation due to density difference. This PCCS has the following characteristic: (1) applicable to concrete containment system, (2) no limitation in plant capacity expansion, (3) efficient steam condensing mechanism (dropwise or film condensation at the surface of condenser tube), and (4) utilization of a fully passive mechanism. A preliminary conceptual design work has been done based on steady-state assumptions to determine important design parameter including the elevation of components and required heat transfer area of the condenser tube. Assuming a decay power level of 2%, the required heat transfer area for 1,000MWe plant is assessed to be about 2,000 ㎡ (equivalent to 1,600 of 10 m-long, 4-cm-OD tubes) with the relative elevation difference of 38 m between the condenser and steam condensing pool and the riser diameter of 0.62 m.

  • PDF

Solidification Analysis Characteristics of Back Flow Prevention Check Valve (역류방지 체크밸브의 응고해석 특성)

  • Yoon, Jung-In;Moon, Jung-Hyun;Son, Chang-Hyo;Lee, Jung-Jin
    • Journal of Power System Engineering
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2015
  • Check valves used in vessels include shock-release function on piping system, aside from basic back flow prevention. However, proper and enough protection of system is not obtainable due to use of high-pressure and bulk fluids, resulting from enlargement of vessels. In this study, casting analysis of check valves protecting systems in flow path from water hammering or back flow is conducted, using Z-CAST program. Also, molten metal filling, flow analysis, solidification analysis and shrinkage cavity analysis are conducted. The main results are as following. Regarding filling of each risering, molten metal showed stable supply condition without being isolated. It was identified that the final solidification exists on risering, but shrinkage cavity possibly might happens at the point of isolation solidification.

C* Based Life Assessment of 3D Crack at High Temperature (C*에 기초한 3차원 고온균열 수명평가)

  • Han, Tae-Soo;Yoon, Kee-Bong;Lee, Hyung-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.5
    • /
    • pp.823-833
    • /
    • 2001
  • In recent years, the subject of remaining life assessment has drawn considerable attention in chemical plants, where various structural components typically operate at high temperature an pressure. Thus a life prediction methodology accounting for high temperature creep fracture is increasingly needed for the components. Critical defects in such structures are generally found in the form of semi-elliptical surface crack, and the analysis of which is consequently an important problem in engineering fracture mechanics. On this background, we first develop an auto mesh generation program for detailed 3-D finite element analyses of axial and circumferential semi-elliptical surface cracks in a piping system. A high temperature creep fracture parameter C-integral is obtained from the finite element analyses of generated 3-D models. Post crack growth module is further appended here to calculate the amount of crack growth. Finally the remaining lives of surface cracked pipes for various analytical parameters are assessed using the developed life assessment program.

New Engineering Method for Non-Linear Fracture Mechanics Analysis Enhanced Reference Stress Method (비선형 파괴역학 해석을 위한 새로운 기법: 개선된 참조 응력법)

  • Kim, Yun-Jae;Kim, Young-Jin
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.17-25
    • /
    • 2001
  • This paper briefly describes the new engineering method, called the enhanced reference stress method, to estimate J (or $C^*$) for non-linear fracture mechanics analysis of defective components, recently proposed by authors. The proposed method offers significant advantages over existing methods in terms of its accuracy, simplicity and robustness. Examples of application of the proposed method to typical piping integrity problems such as through-wall cracked pipes under combined loading, and surface cracked pipes under internal pressure and bending are given. Excellent agreements between the FE J and $C^*$ results and those of the proposed method provide sufficient confidence in the use of the proposed method. One notable point is that the proposed method can be used to estimate J (or $C^*$) along the crack front of surface cracks. Moreover simplicity of the proposed method makes it easy to extend to more complex problems. Thus the proposed method is attractive to assess the significance of defects under practical situations.

  • PDF

Nondestructive Testing and Applications for Integrity Assessment of Power Plant Facilities by Acoustic Emission Technology - Part 1 : The Theory of Acoustic Emission Technology(I) - (발전설비 건전성평가를 위한 음향방출 비파괴검사 적용기술 - 제1편 : 음향방출 비파괴검사기술 이론(I) -)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.5-13
    • /
    • 2005
  • Acoustic emission(AE) is defined as the transient elastic waves thar are generated by the rapid release of energy. The advantage of AE is that very early crack growth can be detected well before a highly stressed component may fail. At present, an exact diagnosis is the most reliable means for determining the soundness of structures during power plant operations. AE monitoring has been applied successfully in power plants to determine mechanical problems, pressure vessel integrity and external valves leaks, vacuum leaks, the onset of cavitation in pumps and valves, the presence of flow(or no flow) in piping and heat exchange equipment, etc. Acoustic emission(AE) technology has recently strengthened its application base, and practitioners' understanding of the technique's fundamentals. This paper introduces the methods of a survey and assessment on AE monitoring applications in nuclear, fossil and hydraulic power plant. The main objective of this paper was to obtain information on various applications of AE technology in power plant.

  • PDF

Optimal Determination of Pipe Support Types in Flare System for Minimizing Support Cost (비용 최소화를 위한 플래어 시스템의 배관 서포트 타입 최적설계)

  • Park, Jung-Min;Park, Chang-Hyun;Kim, Tea-Soo;Choi, Dong-Hoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.4
    • /
    • pp.325-329
    • /
    • 2011
  • Floating, production, storage and offloading (FPSO) is a production facility that refines and saves the drilled crude oil from a drilling facility in the ocean. The flare system in the FPSO is a major part of the pressure relieving system for hydrocarbon processing plants. The flare system consists of a number of pipes and complicated connection systems. Decision of pipe support types is important since the load on the support and the stress in the pipe are influenced by the pipe support type. In this study, we optimally determined the pipe support types that minimized the support cost while satisfying the design constraints on maximum support load, maximum nozzle load and maximum pipe stress ratio. Performance indices included in the design constraints for a specified design were evaluated by pipe structural analysis using CAESAR II. Since pipe support types were all discrete design variables, an evolutionary algorithm (EA) was used as an optimizer. We successfully obtained the optimal solution that reduced the support cost by 27.2% compared to the initial support cost while all the design requirements were satisfied.

Deconvolution Method for TOFD Technique (TOFD 법에서의 근거리 분해능 향상에 관한 연구)

  • Lee, Sun-Heum;Kim, Sun-Hyoung;Kong, Yong-Hae;Lee, Weon-Heum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.6
    • /
    • pp.420-425
    • /
    • 1999
  • Time of flight diffraction(TOFD) method is used in nondestructive tests of piping and pressure vessels because of its advantages over a pulse echo technique: its speed, objectivity, repeatability and its insensitivity to specimen surface conditions and discontinuity orientation. But it is the one of weak points in TOFD method that it has the dead zone in sub-surface resolution induced by lateral waves. We solved the dead-zone problem near the sub-surface by using the deconvolution method and the developed ultrasonic testing system showed high performance.

  • PDF