Time History Analysis of Surge Line Considering PVRC Damping

PVRC 감쇠를 고려한 밀림관의 시간이력해석

  • 김태형 (한국전력기술(주) 원자로설계개발단) ;
  • 전장환 (한국전력기술(주) 원자로설계개발단) ;
  • 김종민 (한국전력기술(주) 원자로설계개발단) ;
  • 윤기석 (한국전력기술(주) 원자로설계개발단) ;
  • 김인용 (한국전력기술(주) 원자로설계개발단)
  • Published : 2006.04.01

Abstract

The PVRC(Pressure Vessel Research Council) damping is for the response spectrum analysis of the piping system. In this study, the possibility to apply it to the time history analysis is evaluated to reduce the higher conservatism for the structural integrity. The evaluation was performed for the surge line connecting the pressurizer to the hot-leg, and the whole mode includes the RCS and the building structures with the surge line. The analyses were performed using ANSYS code. The first modal analysis shows the modes of the surge line are isolated from those of the other structures. The composite modal damping was calculated with PVRC damping for the surge line and RG 1.60 damping for the other structures by using ANSYS routines. Of the calculated composite modal damping values, the composite modal damping values related to the modes of the surge line were replaced with the PVRC damping values with respect to its frequencies. With this replacement, the composite modal damping values of the other structures were not changed. Based on this decouple characteristics, the time history analyses for the seismic events with PVRC damping for the surge line were performed. And the results show the resultant loads can be reduced by up to 50%.

Keywords