• Title/Summary/Keyword: pressure peak

Search Result 1,464, Processing Time 0.041 seconds

Adenosine $^{99m}Tc-MIBI$ Scintigraphy in the Diagnosis of Coronary Artery Disease: Comparison with Exercise $^{99m}Tc-MIBI$ Scintigraphy (관상동맥 질환에서의 Adenosine 부하 $^{99m}Tc-MIBI$ 심근 스캔의 진단적 가치 : 운동 부하 $^{99m}Tc-MIBI$ 심근 스캔과의 비교)

  • Kang, Seung-Wan;Woo, Eon-Jo;Chae, Sung-Chull;Jun, Jae-Eun;Park, Wee-Hyun;Chung, Byung-Cheon;Choi, Chung-Il;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.72-81
    • /
    • 1992
  • Pharmacologic coronary vasodilation in conjunction with myocardial scintigraphy has become an accepted alternative to dynamic exercise testing for the diagnosis of coronary artery disease. Although dipyridamole has traditionally been used for this purpose, it causes frequent side effect, which at times can be life-threatening. Moreover, dipyridamole dose not elicit maximal coronary vasodilation in a substantial number of patients receiving the usual i.v. dose. Adenosine is an endogenously produced compound that has significant effects as a coronary vasodilator and rapid onset action and extremely short half-life (< 10 seconds). The diagnostic accuracy and safety profile of adenosine $^{99m}Tc-MIBI$ myocardial scintigraphy were evaluated and comparison with exercise $^{99m}Tc-MIBI$ was performed. Twenty-eight subjects underwent $^{99m}Tc-MIBI$ imaging after adenosine infusion and exercise $^{99m}Tc-MIBI$ imaging. Adenosine was infused intravenously at a dose of 0.14mg/kg/body weight per minute for 6 min and MIBI was injected at 3 minute. Adenosine caused an incerease in heart rate ($64{\pm}12$ at baseline versus $74{\pm}16$ beats/min at peak effect, p<0.001), a mild decrease in systolic and diastolic blood pressure and a slightly increase in PR interval(p; NS). Side effects were reported in 92% of patients and were mostly mild in nature and promptly resolved within 1 or 2 minutes of termination of adenosine infusion. Facial flushing (53%), chest pain (36%), mild dyspnea (39%), headache (21%), throat discomfort (21%) were frequent symptoms. ST segment depression (> 1 mm) and second degree AV block in electrocardiography occured in 11% of the patients, respectively. The overall sensitivity and specificity for individual coronary stenoses in 16 patients underwent coronary angiography were 88% and 95%, respectively. The agreement ratio of segmental perfusion between adenosine and exercise images was 92% (Kappa index=0.82). In conclusion, $^{99m}Tc-MIBI$ myocardial perfusion scintigraphy with intravenous adenosine is a feasible, safe and highly accurate noninvasive technique for the detection of coronary artery disease and results are at least comparable with those of exercise $^{99m}Tc-MIBI$ scintigraphy.

  • PDF

Determination of Natural Gas Components by Gas Chromatographic Multicolumn System (기체 크로마토그래피 복합컬럼 시스템에 의한 천연가스 성분의 정량)

  • Choi, Yong-Wook;Choe, Kun-Hyung
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.339-347
    • /
    • 1994
  • A multicolumn system consisted of two valve(10-port and 6-port valve)-three column (28% DC 200, SP 1700 and Chromosorb 102 column) was developed. Nine natural gas components composed of $N_2$, $CH_4$, $CO_2$, $C_2H_6$, $C_3H_8$, $i-C_4H_{10}$, $n-C_4H_{10}$, $i-C_5H_{12}$$n-C_5H_{12}$ completed all the baseline separation within 18 minutes. The accuracy and the precision of this system was tested. The retention times and the peak areas were determined with a repeatability between 0.02 and 0.16%, and less than 1%, respectively. Calibration curves for natural-gas components were plotted by the partial pressure injection method of pure gases, and good linear relationships for each component were presented. By using these calibration curves the accuracy of the multicolumn system compaired with that of the single column system for a certified standard gas of natural gas. As a result, relative error in the single and the multicolumn system was less than 0.5% and 0.04%, respectively. The result of application of this system in the analysis of importing LNG composition showed that the heating values calculated by the multicolum system were estimated lower compared with those calculated by the single column system and consequently, the importing price of LNG was able to be cut down.

  • PDF

Fabrication of the Plasma Focus Device for Advanced Lithography Light Source and Its Electro Optical Characteristics in Argon Arc Plasma (차세대 리소그래피 빛샘 발생을 위한 플라스마 집속 장치의 제작과 아르곤 아크 플라스마의 발생에 따른 회로 분석 및 전기 광학적 특성 연구)

  • Lee S.B.;Moon M.W.;Oh P.Y.;Song K.B.;Lim J.E.;Hong Y.J.;Yi W.J.;Choi E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.380-386
    • /
    • 2006
  • In this study, we had designed and fabricated the plasma focus device which can generate the light source for EUV(Extreme Ultra Violet) lithography. And we also have investigated the basic electrical characteristics of currents, voltages, resistance and inductance of this system. Voltage and current signals were measured by C-dot and B-dot probe, respectively. We applied various voltages of 1.5, 2, 2.5 and 3 kV to the anode electrode and observed voltages and current signals in accordance with various Ar pressures of 1 mTorr to 100 Torr in diode chamber. It is observed that the peak values of voltage and current signals were measured at 300 mTorr, where the inductance and impedance were also estimated to be 73 nH and $35 m{\Omega}$ respectively. The electron temperature has been shown to be 13000 K at the diode voltage of 2.5 kV and this gas pressure of 300 mTorr. It is also found that the ion density Ni and ionization rate 0 have been shown to be $N_i = 8.25{\times}10^{15}/cc$ and ${\delta}$= 77.8%, respectively by optical emission spectroscopy from assumption of local thermodynamic equilibrium(LTE) plasma.

Studies on Magnetic Properties of Die-upset Pr-Fe-B Magnets (Die-upset법에 의한 Pr-Fe-B자석의 자기적 성질에 관한 연구)

  • 이경섭;서수정;박현순;이병규;정지연
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.3
    • /
    • pp.201-207
    • /
    • 1993
  • Starting ingot of $Pr_{15}Fe_{77}B_{8}$ were prepared by vacuum induction melting under argon atmosphere. The ingot were induction melted in a quartz crucible and then ejected as a molten alloy throuth a 0.6 mrn orifice onto a rotating cop¬per wheel. An anisotropic magnet was prepared from ribbon by hot deformation techniques. A fully dense precursor magnet first made by pressing ribbons at $680^{\circ}C$ under a pressure of $21.8\;kg/mm^{2}$. A substantially oriented magnets were obtained by die-upset under various conditions. As the compression ratio increases, the $B_{r}$ value increases pronouncedly though $_{i}H_{c}$ decreases. Also, XRD analyses show increased diffraction peak from (006). From these results, it can be known that the magnetic easy axis was formed along the compression axis. As the die-upset speed increases, $_{i}H_{c}$ increases though $B_{r}$ decreases. The $B_{r}$ increases up to $750^{\circ}C$ of die-upset temperature and above this temperature decreases. The value of $4{\pi}M_{s}$ of the $Pr_{15}Fe_{77}B_{8}$ alloy prepared is found to be 11.8 KG. When the alloy was compressed by 0.8 under the die-upset speed of 0.05 m/sec at $750^{\circ}C$, $B_{r}$ was 11.0 KG indicating that the alloy has excellent magnetic anistropy. However, this alloy has some limitation because of low $_{i}H_{c}$.

  • PDF

The Comparison Research on Walking Pattern of Rehabilitation Training Program Participants in Stroke Patients (재활운동에 참가한 뇌졸중 환자들의 걷기형태 비교 연구)

  • Jin, Young-Wan
    • Journal of Life Science
    • /
    • v.19 no.9
    • /
    • pp.1299-1303
    • /
    • 2009
  • The purpose of this study was to analyse the gait characteristics of stroke patients walking on a Zebris system, through quantitative three-dimensional biomechanical analysis. They underwent a continuous rehabilitation training program (RTP). A comparison was made between 3 month and 6 month RTP participants. Their ages were between 60 and 65. The data were analyzed by t-test. The result of comparative analysis of the two groups can be summarized as below. Temporal-spatial data, sagittal plane angular kinematics data, and peak ground reaction force and max pressure data showed that there were no significant differences between the 3 month RTP group and the 6month RTP group (Table 2, Table3, Table 4). It can be suggested that patients with hemiplegia after stroke can improve their walking function through continuous RTP participation.

Hydrothermal Synthesis of Ultra-fine SrAl2O4:Eu Powders and Investigation of their Photoluminescent Characteristics (수열합성법에 의한 SrAl2O4:Eu 초미세 분말 합성공정 및 형광 특성)

  • 박우식;김선재;김정식
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.5
    • /
    • pp.370-374
    • /
    • 2004
  • Sr$_{l-x}$Ba$_{x}$Al$_2$O$_4$:Eu (x = 0, 0.1, 0.2, and 0.3 mol) phosphor was synthesized by the hydrothermal method and its properties of photoluminescence and long-afterglow were investigated. The mixtures of Sr(NO$_3$)$_2$, Al(NO$_3$)$_3$9$H_2O$, and Eu(NO$_3$)$_3$$.$6$H_2O$ salts dissolved in distilled water, after controlling their pH by NH$_4$OH solution, put into an Autoclave reactor with high temperature and pressure to react. Such synthesized SrAl$_2$O$_4$:Eu powders showed homogeneous and ultra-fine particles of sub-micron size. In order to have the photoluminescence characteristic, powders were heat treated at 1100 -140$0^{\circ}C$ for 2 h in Ar/H$_2$ reduction atmosphere. Photoluminescence spectra showed a excitation along the wide wavelength of 250 ∼ 450 nm, and broaden emission with maxima peak at 520 nm. Also, it showed a good long afterglow with decaying over 1000 sec after excitation illumination for 10 min. In addition, the microstructure and crystal structure of SrAl$_2$O$_4$:Eu powders were investigated by an SEM and XRD, respectively.

Properties of High Power Flip Chip LED Package with Bonding Materials (접합 소재에 따른 고출력 플립칩 LED 패키지 특성 연구)

  • Lee, Tae-Young;Kim, Mi-Song;Ko, Eun-Soo;Choi, Jong-Hyun;Jang, Myoung-Gi;Kim, Mok-Soon;Yoo, Sehoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Flip chip bonded LED packages possess lower thermal resistance than wire bonded LED packages because of short thermal path. In this study, thermal and bonding properties of flip chip bonded high brightness LED were evaluated for Au-Sn thermo-compression bonded LEDs and Sn-Ag-Cu reflow bonded LEDs. For the Au-Sn thermo-compression bonding, bonding pressure and bonding temperature were 50 N and 300oC, respectively. For the SAC solder reflow bonding, peak temperature was $255^{\circ}C$ for 30 sec. The shear strength of the Au-Sn thermo-compression joint was $3508.5gf/mm^2$ and that of the SAC reflow joint was 5798.5 gf/mm. After the shear test, the fracture occurred at the isolation layer in the LED chip for both Au-Sn and SAC joints. Thermal resistance of Au-Sn sample was lower than that of SAC bonded sample due to the void formation in the SAC solder.

Soft Plasma Flash X-ray Generator Utilizing a Vacuum Discharge Capillary

  • Sato, Eiichi;Hayasi, Yasuomi;Usuki, Tatsumi;Sato, Koetsu;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.400-403
    • /
    • 2002
  • The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments were primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -10.8 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 ${\mu}$m aluminum filter were less than 30 ${\mu}$s, and we detected the aluminum characteristic x-ray intensity using a 6.8 ${\mu}$m aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted and diffused greatly after passing through two slits.

  • PDF

The Risk Factors of Recurrent Ischemic Stroke (허혈성 뇌졸중의 재발과 연관된 위험인자)

  • Jung, Cheol;Kim, Wook-Nyneon;Kim, Min-Jeung;Choi, Soek-Mum;Eur, Kyung-Yoon;Park, Mee-Young;Hah, Jeng-Sang;Byun, Yeung-Ju
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.423-431
    • /
    • 1993
  • To eveluate the risk factors which are related to recurrence of ischemic stroke, we selected subjects who were admitted to YNUH due to recurrent stroke and compared their risk factors with non-recurred group who suffered from single ischemic stroke. In the subjects, 55 of them are men and 22 were women and in the non-recurred groups, 84 of them were men and 40 were women, Subject's age ranged from 29 to 85 years(Mean 62, 5years), and non-recurred group's age ranged from 27 to 90 years(Mean 60, 7years), Peak incidence of ischemic stroke is in the 7th decade in both groups. Age and sex are not, statistically significant for recurrence of ischemic stroke. The patient's history of diabetes mellitus, myocardial infarction, atrial fibrillation, transient attack and type or site of ischemic stroke had no significant effect statistically on the recurrent ischemic stroke. However, when the patient had previous history of hypertension or systolic blood pressure more than 160mmHg and diastolic more than 95mmHg, there was substantial difference(P<0.05) between the two group in the recurrence of ischemic stroke. According to the above results, hypertension is most likely significant risk factor of the recurrence of ischemic stroke within 2years after initial one. Therefore, adequate treatment of the hypertension is important for the prevention of ischemic stroke. Further study is required for searching other risk factors.

  • PDF

A Study on Standard Ocean Lighted Buoy Type System for Real-time Ocean Meteorological Observation (실시간 해양관측을 위한 표준형 등부표용 시스템 연구)

  • Park, Sanghyun;Park, Yongpal;Bae, Dongjin;Kim, Jinsul;Park, Jongsu
    • Journal of Digital Contents Society
    • /
    • v.19 no.9
    • /
    • pp.1739-1749
    • /
    • 2018
  • We propose a marine observation system using existing light buoys to observe various marine information of marine locations. Our proposed ocean observation system is composed of the existing standard light buoy type and can be easily connected to the light buoy. The proposed marine observation system measures the mean wave height, maximum wave height, mean wave height and water temperature measured in the ocean. Besides, it can measure the air pressure, temperature, wind speed and wind speed in real time. In order to measure important peaks in marine observations, 2200 peak data are collected for 10 minutes, and the collected data are subjected to spectral analysis to extract significant wave and wave period data. The developed system removes the noise by using the filter because the marine observation system attaches to the light buoy. We compare and analyze the measurement data of the existing proven floating marine observation system and the standard equivalent system developed. Also, it is proved that the data of the standard type backbone ocean observation system developed through the comparative experiment is similar to that of the existing ocean observation system.