• Title/Summary/Keyword: pressure in tube

Search Result 1,951, Processing Time 0.032 seconds

Design of a pilot-scale helium heating system to support the SI cycle (파이롯 규모 SI 공정 시험 설비에서의 헬륨 가열 장치 설계)

  • Jang, Se-Hyun;Choi, Yong-Suk;Lee, Ki-Young;Shin, Young-Joon;Lee, Tae-Hoon;Kim, Jong-Ho;Yoon, Seok-Hun;Choi, Jae-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.157-164
    • /
    • 2016
  • In this study, researchers performed preliminary design and numerical analysis for a pilot-scale helium heating system intended to support full-scale construction for a sulfur-iodine (SI) cycle. The helium heat exchanger used a liquefied petroleum gas (LPG) combustor. Exhaust gas velocity at the heat exchanger outlet was approximately 40 m/s based on computational thermal and flow analysis. The maximum gas temperature was reached with six baffles in the design; lower gas temperatures were observed with four baffles. The amount of heat transfer was also higher with six baffles. Installation of additional baffles may reduce fuel costs because of the reduced LPG exhausted to the heat exchanger. However, additional baffles may also increase the pressure difference between the exchanger's inlet and outlet. Therefore, it is important to find the optimum number of baffles. Structural analysis, followed by thermal and flow analysis, indicated a 3.86 mm thermal expansion at the middle of the shell and tube type heat exchanger when both ends were supported. Structural analysis conditions included a helium flow rate of 3.729 mol/s and a helium outlet temperature of $910^{\circ}C$. An exhaust gas temperature of $1300^{\circ}C$ and an exhaust gas rate of 52 g/s were confirmed to achieve the helium outlet temperature of $910^{\circ}C$ with an exchanger inlet temperature of $135^{\circ}C$ in an LPG-fueled helium heating system.

A Study on the characteristic analysis and optimization according to Ballast design of Induction Lamp (고출력 무전극램프의 점등회로 설계를 통한 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Park, Dae-Hee;Kim, Yong-Kab
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.31-37
    • /
    • 2017
  • In this paper, we implemented for the development of a high output induction lamp system, which lamp design is optimized by gas type, mixing ratio, pressure and discharge tube size, amalgam type and mixing ratio, and characteristics of ferrite core in the lamp. It's the circuit design by improving the power factor and efficiency according to the driving method, which has analyzing the characteristics according to the waveform and frequency. Finally, luminaries design part for applying the optimal lighting system considering the surrounding environment, the characteristics of the lighting circuit for electrodeless lamp has analyzed and the improvement has been proceeded. In conclusion, the driving frequency has optimized at 135kHz with degrading $7{\sim}10^{\circ}C$ based on the results of the optical characteristics of the induction lamp on peak noise FET(Q3,Q4) damage.

Skeletal Muscle Ventricle Mechanics (골격근 심실의 역학)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.428-432
    • /
    • 1999
  • Background: It has been shown that low-grade electrical stimulus can transform fatigue resistant muscles which then can be used to protect the heart. The bulky and cumbersome power sources of the artificial heart or implantable ventricular assist devices are still in need of solution; however, on the other hand, the implantable ventricular assist devices using the resistant muscles as the power source have the advantages of using its own muscle contractions. The purpose of this study was to determine the possibility of a clinical application of the skeletal muscle ventricle. Material and Method: Latissimus dorsi muscles (LDM) of 8 canines were used for skeletal muscle ventricle. A latex chamber was wrapped one and a half times with LDM. The chamber was attached to a pressure transducer via Tygon tube. An electrode stimulator was placed around the thoracodorsal nerve and LDM was stimulated in cyclic bursts of 0.31 sec on time and 6.0 sec off time using 3.0 volt Itrel stimulator. The preload volume was added to the system in 25cc increments. Ejection volumes, pressures, and peak power outputs were measured. Result: Ejection volume was 76.3cc with 0cc of preload. Ejection volumes were less than 70ml with increments of preload over 75cc Pressures were more than 107 mmHg when the preloads were less than 75cc and less than 100 mmHg when the preloads were more than 100cc. Peak power output of 16.6 W/kg was observed at 50cc preload. Conclusion: Depending on the changes of preload, the volumes ejected from skeletal muscle ventricle and pressures from the skeletal muscle contraction surpassed those of the normal heart. These data suggest that there are clinical applications for skeletal muscle ventricular assist system.

  • PDF

Mercury Quantity in a Fluorescent Lamp for a Backlight of LCD-TVs (LCD-백라이트용 형광램프의 수은량)

  • Bong, Jae-Hwan;Kim, Yun-Jung;Hwang, Ha-Chung;Jin, Dong-Jun;Jeong, Jong-Mun;Kim, Jung-Hyun;Koo, Je-Huan;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.495-500
    • /
    • 2008
  • The amount of vapor mercury for the generation of glow discharge plasma has been calculated in a fine tube fluorescent lamp having a mixed gas of Ne+Ar including a mercury. When the ionization of atom is considered by the collision between neutral atoms (Ne, Ar, Hg) and electrons of energy $kT_e{\sim}1\;eV$, the density of vapor mercury atom has been obtained as $n(Hg){\sim}3.43{\times}10^{22}m^{-3}$ for the plasma density $n_o{\sim}10^{17}m^{-3}$. In the fluorescent lamps of out diameter 4 mm used for $32{\sim}42$-inch LCD-TVs having a mixture gas of Ne(95%)+Ar(5%) with the pressure of 50 Torr, the quantity of vapor mercury for the glow discharge has been caculated as 0.02{\sim}0.08\;mg$.

The Fundamental Studies and Development of the Modified See - Through Hollow Cathode Glow Discharge Cell for Atomic Emission Spectrochemical Analysis (원자 방출 분광 분석을 위한 개선된 관통형 속빈 음극관 글로우 방전 셀 개발 및 기초 연구)

  • Lee, Sung-Hun;Cho, Won-Bo;Jeong, Jong-Pil;Choi, Woo-Chang;Borden, Stuart;Kim, Kyu-Whan;Lee, Change-Su;Lee, Sang-Chun
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.502-508
    • /
    • 2002
  • See-through hollow cathode glow discharge cell has been developed for the trace analysis of metal ions. The systems consists of new glow discharge cell improved the cooling system. In the case of previous type of hollow cathode glow discharge cell, it had been utilized for the trace analysis of metal ions but it had a problem that the plasma becomes unstable by air-cooled device. In this study, the modified hollow cathode glow discharge cell has been developed in order to minimize the problem associated with the air-cooled device. thus the stability of the plasma with water-cooling device has been improved and also the higher plasma temperature has been measured. The fundamental characteristics of modified systems have been investigated. And the discharge parameters, such as discharge pressure, material, and diameter of cathode, have been studied to find optimum discharge conditions.

Modified Fontan Operation: Physio-anatomic Causes of Low Cardiac Output and Persistent Pleural Effusion (Fontan 수술후 저심장박출증 및 지속성 흉막 삼출액이 발생되는 해부생리학적 원인)

  • Han, Jae-Jin;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.213-221
    • /
    • 1990
  • We have experienced 62 cases of modified Fontan operations in Seoul Nat’l University Hospital from Apr. 1986 to Jul. 1989, They were 38 males and 24 females, and their age was ranged from 16 months to 15.5 years of age. [mean age : 5.73$\pm$2.99 years] There were 16 operative deaths and 2 late deaths, therefore 29% of overall mortality. Their diagnoses were as follows; 28 single ventricle, 11 tricuspid atresia, 6 DORV with LV hypoplasia, 3 pulmonary atresia with hypoplastic RV, 3 TGA with hypoplastic RV, 3 cor\ulcornerGA with hypoplastic LV and PA, 6 AV canal defects with PA, and 2 others. Low cardiac output and pleural effusion were developed frequently, so we divide 40 patients into some groups to analyze the physiologic and anatomic causes of them. By the degree of the LCO, group A was no LCO[mean amount of inotropics used: 0-5 \ulcornerg/kg/min] with 17 cases, B mild LCO [5-10] with 11, C moderate to severe LCO but alive[>10] with 8, D severe LCO to death with 4 cases. For the pleural effusion, group 1 was to be removed the chest tube within 1 week with 8 cases, group II within 3 weeks with 21 cases, group III beyond 3 weeks with 12 cases. We considered their age, diagnosis, pulmonary artery size[PA index], pulmonary artery abnormality, palliative shunt, systemic ventricular type, pulmonary artery wedge pressure, as preoperative factors, and operative methods, and as postoperative factors, CVP, LAP, arrhythmia, thrombosis, atrioventricular valvular insufficiency, etc. In the view of LCO, pulmonary artery size and PCWP were statistically significant [P<0.05], and arrhythmia, A-V valve insufficiency were inclined to the group C and D Pleural effusion was influenced by the pulmonary artery size, pulmonary artery resistance, PCWP, and CVP significantly. [P<0.05] And arrhythmia, residual shunt, and A-V valvular insufficiency were inclined to group II and III, too. As a results, the followings are to be reminded as the important factors at the care of post-Fontan LCO, and persistent pleural effusion [1] pulmonary artery size, [2] pulmonary artery resistance, [3] PCWP, [4] CVP, [5] arrhythmia, [6] residual shunt, [7]A-V valvular insufficiency.

  • PDF

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

Development of FURA Code and Application for Load Follow Operation (FURA 코드 개발과 부하 추종 운전에 대한 적용)

  • Park, Young-Seob;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.88-104
    • /
    • 1988
  • The FUel Rod Analysis(FURA) code is developed using two-dimensional finite element methods for axisymmetric and plane stress analysis of fuel rod. It predicts the thermal and mechanical behavior of fuel rod during normal and load follow operations. To evaluate the exact temperature distribution and the inner gas pressure, the radial deformation of pellet and clad, the fission gas release are considered over the full-length of fuel rod. The thermal element equation is derived using Galerkin's techniques. The displacement element equation is derived using the principle of virtual works. The mechanical analysis can accommodate various components of strain: elastic, plastic, creep and thermal strain as well as strain due to swelling, relocation and densification. The 4-node quadratic isoparametric elements are adopted, and the geometric model is confined to a half-pellet-height region with the assumption that pellet-pellet interaction is symmetrical. The pellet cracking and crack healing, pellet-cladding interaction are modelled. The Newton-Raphson iteration with an implicit algorithm is applied to perform the analysis of non-linear material behavior accurately and stably. The pellet and cladding model has been compared with both analytical solutions and experimental results. The observed and predicted results are in good agreement. The general behavior of fuel rod is calculated by axisymmetric system and the cladding behavior against radial crack is used by plane stress system. The sensitivity of strain aging of PWR fuel cladding tube due to load following is evaluated in terms of linear power, load cycle frequency and amplitude.

  • PDF

Numerical Analysis of Flow Characteristies inside innes part of Fluid Control Valve System (유동해석을 통한 유체제어벨브 시스템의 내부 유동 특성 분석)

  • Son, Chang-Woo;Seo, Tae-Il;Kim, Kwang-Hee;Lee, Sun-Ryong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.160-166
    • /
    • 2018
  • The worldwide semi-conductor market has been growing for a long time. Manufacturing lines of semi-conductors need to handle several types of toxic gases. In particular, they need to be controlled accurately in real time. This type of toxic gas control system consists of many different kinds of parts, e.g., fittings, valves, tubes, filters, and regulators. These parts obviously need to be manufactured precisely and be corrosion resistant because they have to control high pressure gases for long periods without any leakage. For this, surface machining and hardening technologies of the metal block and metal gasket need to be studied. This type of study depends on various factors, such as geometric shapes, part materials, surface hardening method, and gas pressures. This paper presents strong concerns on a series of simulation processes regarding the differences between the inlet and outlet pressures considering several different fluid velocity, tube diameters, and V-angles. Indeed, this study will very helpful to determine the important design factors as well as precisely manufacture these parts. The EP (Electrolytic Polishing) process was used to obtain cleaner surfaces, and hardness tests were carried out after the EP process.

Tracheal Reconstruction with Perichondrial Graft - An Experimental Study in Rabbits - (연골피막편 이식후 기관 결손부위의 재생에 관한 실험적 연구(제 1 보))

  • 이원상;서장수;이성은;홍원표;박찬일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.10.3-11
    • /
    • 1982
  • Recently through the advancement of medical and surgical managements and the development of low pressure cuffed endotracheal tube, incidence of tracheal stenosis was decreased significantly. Though its incidence was decreased markedly, stenosis was developted unfortunately in the situations such as long term use of respirator, heavy infection, trauma of the trachea and long term intubation etc. Tracheal stenosis had been handled with various methods such as mechanical dilatation, tissue graft techniques, luminal augumentation and end to end anastomosis due to their individual advantages but their effects were not satisfactory. In 1959 Lester had been found the regenerated cartilage from the perichondrium of the rib incidentaly. Since then Skoog, Sohn and Ohlsen were reported chondrogenic potential of perichondrium through the animal experiments. Though many different materials have been tried to rebuild stenosis and gaping defect of trachea, tracheal reconstruction has been a perplexing clinical problems. We choose the perichondrium as the graft material because cartilage is the normal supporting matrix of that structure and it will be an obvious advantage to be able to position perichondrium over a defect and obtain new cartilage there. The young rabbits, which were selected as our experimental animals, were sacrified from two to eight weeks after surgery. The results of our experiment were as follows; 1) In control group, the defect site of trachea was covered with fibrosis and vessels but graft site was covered with hypertrophied perichondrium and vessels. 2) Respiratory mucosa was completely regenerated in defect sites both control and grafted groups. 3) The histologic changes of the grafted sites were as follows: 2 weeks- microvessel dilatation, inflammatory reaction, initiation of fibrosis 4 weeks- decreased microvessel engorgement, submucosal fibrosis, decreased inflammatory reaction immatured cartilage island was noted in the grafted perichondrium (one specimen) 6 weeks- mild degree vascular engorgement submucosal fibrosis. chronic inflamatory reaction cartilage island and endochondrial ossification was noted in the grafted perichondrium (Two specimens) 8 weeks- minute vascular engorgement dense submucosal fibrosis. loss of inflammatory reaction. cartilage island was noted in the grafted perichondrium (two specimens) 4) There was no significant differences in regeneration between active surface in and out groups. 5) We observed immatured cartilage islands and endochondrial ossification in the perichondrial grafted groups where as such findings were not noted in control groups except fibrosis. We concluded that perichondrium was the adequate material for the reconstruction of defected trachea but our results was not sufficient in the aspect of chondrogenic potential of perichondrium. So further research has indicated possibility of chondrogenic potential of perichondrium.

  • PDF