• 제목/요약/키워드: pressure housing

검색결과 274건 처리시간 0.03초

Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems

  • Song, J.I.;Park, K.H.;Jeon, J.H.;Choi, H.L.;Barroga, A.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제26권3호
    • /
    • pp.433-442
    • /
    • 2013
  • This study aimed to compare the dynamics of air temperature and velocity under two different ventilation and housing systems during summer and winter in Korea. The $NH_3$ concentration of both housing systems was also investigated in relation to the pig's growth. The ventilation systems used were; negative pressure type for the enclosed pig house (EPH) and natural airflow for the conventional pig house (CPH). Against a highly fluctuating outdoor temperature, the EPH was able to maintain a stable temperature at 24.8 to $29.1^{\circ}C$ during summer and 17.9 to $23.1^{\circ}C$ during winter whilst the CPH had a wider temperature variance during summer at 24.7 to $32.3^{\circ}C$. However, the temperature fluctuation of the CPH during winter was almost the same with that of EPH at 14.5 to $18.2^{\circ}C$. The NH3 levels in the CPH ranged from 9.31 to 16.9 mg/L during summer and 5.1 to 19.7 mg/L during winter whilst that of the EPH pig house was 7.9 to 16.1 mg/L and 3.7 to 9.6 mg/L during summer and winter, respectively. These values were less than the critical ammonia level for pigs with the EPH maintaining a lower level than the CPH in both winter and summer. The air velocity at pig nose level in the EPH during summer was 0.23 m/s, enough to provide comfort because of the unique design of the inlet feature. However, no air movement was observed in almost all the lower portions of the CPH during winter because of the absence of an inlet feature. There was a significant improvement in weight gain and feed intake of pigs reared in the EPH compared to the CPH (p<0.05). These findings proved that despite the difference in the housing systems, a stable indoor temperature was necessary to minimize the impact of an avoidable and highly fluctuating outdoor temperature. The EPH consistently maintained an effective indoor airspeed irrespective of season; however the CPH had defective and stagnant air at pig nose level during winter. Characteristics of airflow direction and pattern were consistent relative to housing system during both summer and winter but not of airspeed. The ideal air velocity measurement favored the EPH and therefore can be appropriate for the Korean environment. Further emphasis on its cost effectiveness will be the subject of future investigations.

An Exploratory Study of Energy Conservation Practices in Clothing, Food, and Housing ($\cdot$$\cdot$주별 열에너지 소비절약 실태에 관한 조사연구)

  • 강혜원
    • Journal of the Korean Home Economics Association
    • /
    • 제19권2호
    • /
    • pp.11-24
    • /
    • 1981
  • The objectives of the study were to determine 1) if energy consumption and conservation vary in clothing, food, and housing with independent variables-size of household, homemaker's age, employment, and level of education, level of living, type of house, electricity use, and all energy use, and 2) if there is a correlation among energy conservation practices in clothing, food, and housing. Questionnaires wee given to the randomly selected homemakers in Seoul in July, 1980. Data from 620 responses were analyzed by F-test (Analysis of Variance) and Correlation. The results are as follows: 1. Clothing (1) the scores of the conservation practices I clothing were generally high. /However, it was found that a) they did not practice in wearing heavy under clothes and behavior outer clothing to cope with cool room temperature in the winter, b) they did not use bleach for laundry, but they used boiling method, and c) they did not have enough knowledge on Permanent Press finish. (2) energy conservation practices in clothing were significantly related to level of living and homemakrer's level of education. a) The higher the level of living, the higher scores in the knowledge were found. b) the higher the homeakcer's level of education, the higher scores in the knowledge and ironing were obtained. 2. Food (1) The scores of the conservation practices in food were generally high. However, it was found that scientific cooking methods were not performed such as a) to use measuring spoons, cups, and timers, b) to practice a simple method in using solor energy for warming water, c) to use thermos for the hot water tea or coffee, but they boiled water whenever necessary, and b) to use the pressure cooker whenever possible. (2) Energy conservation practices in food were significantly related to homemaker's employment and type of dwellings. a) The scores of full-time homemakers (not gainfully employed) were higher than gainfully employed homemakers. b) Families in traditional Korean dwellings revealed higher scores than those in apartment or western style dwellings. 3. Housing (1) The scores of the conservation practices in housing were generally high. However, it was found that a) they did not install fans in the kitchen, bathroom, and attic in the summer, b) they did not install a humidifier for tolerating a lower room temperature in the winer, c) they did not practice to make plans for the door of the refrigerator remained open for the shortest time, d) they did not install or use a local lighting with a general lighting for reading and cooking, and e) they usedaluminum foil without the knowledge of the heat reaction of its shiny and dull sides. (2) energy conservation practices in housing were significantly related to homemaker's employment and level of education, economic status, types of dwelling, and all energy use, a) Full-time homeakers had higher scores than gainfully employed homeakers. b) the higher the homemaker's level of education and economics status, the higher scores were obtained. c) Homeakers with their own house scored higher points than those with rented houses. And families in apartment or row houses scored higher points than those in traditional korean or western style dwellings. d) The higher the consumption rate of electricity and all energy, the higher scores were revealed. 4. correlation there was a significant correlation among energy conservation practices I clothing, food, and housing.

  • PDF

Analysis on the characteristics of the earth pressure distribution induced by the integrated steel pipe-roof construction (일체형 강관 파이프루프 시공에 따른 주변 지반의 토압 분포 특성 분석)

  • Sim, Youngjong;Jin, Kyu-Nam;Song, Ki-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • 제15권5호
    • /
    • pp.455-468
    • /
    • 2013
  • In recent, various types of steel pipe-roof methods, which is reinforced by mortar after propulsion of steel pipe into the ground, have been used for the construction of trenchless underpass. Integrated steel pipe-roof has flexural stiffness and can resist against overburden load and reduce the stress acting on the concrete underpass structures. Due to arching effect, vertical and horizontal stress distribution around the steel pipe-roof is changing. In this study, therefore, the characteristic of stress distribution around the underpass induced by the construction of integrated steel pipe-roof is investigated by using numerical method. To examine the soil-structure interaction, interface element is introduced. Results show that vertical stress acting on the concrete structure placing inside the steel pipe-roof is significantly reduced due to arching effect and flexural stiffness of integrated steel pipe-roof. Design load can be reduced and effective design of underpass will be available if the earth pressure reduction due to arching effect is considered in the design stage.

Optimal Design of CEDM considering the Dynamic Characteristics (제어봉 구동장치의 동적 특성을 고려한 최적설계)

  • 김인용;진춘언;김민규
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 한국전산구조공학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.147-151
    • /
    • 1997
  • The dynamic characteristics of Control Element Drive Mechanism (CEDM) in Korea standard Nuclear Power Plant was reviewed as a secondary mass in a simplified two degree of freedom system, while the reactor vessel as a primary mass. The design improvement stratege to minimize each displacement amplitude of these primary and secondary masses was proposed. According to this stratege the designs of CEDM components, the shroud and the pressure housing, respectively, were changed using optimization technique.

  • PDF

Relationship between atrial pressures and the interventricular pressure in the moving actuator type total artificial heart (심실간 공간 압력을 이용한 이동작동기형 완전이식 인공심장에서의 좌, 우심방압 추정)

  • Jo, Y.H.;Choi, W.W.;Park, S.K.;Choi, J.S.;Lee, J.J.;Om, K.S.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.88-90
    • /
    • 1996
  • The right and left atrial pressures are important parameters in automatic control of a total artificial heart (TAH) within normal physiological ranges. Our TAH is composed of a moving actuator, right and left ventricles and the interventricular space enclosed by a semi-rigid housing. During operation of the TAH, the jnterventpicular space's volume is changed dynamically by the difference between the ejection volume of one ventricle and the inflow volume of the other. Therefore, the changes in pressure of the interventricular space is related to both atrial pressures. We measured the interventricular pressure (IVP) waveform using a pressure sensor and attempted to indirectly estimate the changes of atrial pressures. This method has an advantage that the sensor does not contact the blood directly. Furthermore, the IVP waveforms have its zero baseline in each pump cycle, thus the pressure measurements are free from the transducer drift problems by measuring the peak pressure from these baseline values. From the In vitro experiments, we found that the IVP waveform contained several useful parameters such as negative peak, dP/dT on the initial break, the area enclosed by the profile in each stroke, which are associated with atrial pressures and the filling conditions of the ventricles. The measured atrial pressures were linearly related to the negative peak of the interventricular pressure.

  • PDF

An Investigation of the Delivery of Public Rental Housing in Redevelopment Site in Korea (재개발임대주택 공급제도의 도입상황 및 특징분석)

  • Park, Shinyoung
    • Land and Housing Review
    • /
    • 제12권3호
    • /
    • pp.51-65
    • /
    • 2021
  • There were strong criticisms against the joint development method: the redevelopment corporation and developers would achieve the whole development profit. The existing tenants who lost their housing in the site argued their right to reside in the site after the development was completed. There was also strong political pressure that the Roh Tae-woo governing administration should resolve the social inequality caused by the situation. In such circumstances, it was introduced that a certain proportion of public rental housing should be built in the redevelopment site; then the government took over the dwellings at a price of construction and allocated them to the existing tenants. The aims of this paper are to understand the rationale behind the inclusion of the public rental housing in the redevelopment sites; and to investigate to what extent the legislation was implemented appropriately. Although the legislation was introduced in Seoul from August 1989, it was not until May 2005 when it was implemented nationwide. At the beginning, there was an ambiguous rule that the number of public housing to be included should be limited to the number of households who would want to remain in the redeveloped site. In 2005 the Seoul metropolitan authority introduced a mandatory proportion; 17% of the total housing delivered in the site should be public rental homes. Since then the proportion. The proportion has been fluctuated by the political agenda of each ruling party: the conservative tended to reduce the proportion, whilst the opposition parties increased the proportion. Currently the proportion is 20% of the total stock to be built. Initially the size of the public housing was exceptionally small- less than 40 m2 but it has increased up to 60 m2 since 2010. The rental price was reasonably lower than market rent. The competition toward redevelopment rental housing that are vacant due to move or death of tenants was very high; it was given to one household out of nine eligible households in 2020.

Analysis of Lubrication and Dynamic Characteristics of a Cylinder Block for Hydraulic Pump (유압펌프용 실린더 블록의 윤활 및 동특성 해석)

  • 안성용;임윤철;홍예선
    • Tribology and Lubricants
    • /
    • 제20권4호
    • /
    • pp.209-217
    • /
    • 2004
  • Lubrication characteristics between a cylinder block and a valve plate for high speed bent-axis type hydraulic pump play an important role in volumetric efficiency and durability of pump. In this paper, a finite element method is presented for the computation of the pressure distribution between a cylinder block and a valve plate for high speed bent-axis type hydraulic pump. Also, a Runge-Kutta method is applied to simulate the cylinder block dynamics of three-degrees of freedom motion. From the results of computation, we can draw two major conclusions. One is related to the fluid film characteristics between a cylinder block and a valve plate and the other is related to the average leakage that is determined by the pressure gradient and the clearance near the discharge port. The numerical results of cylinder block dynamics were compared with the experimental results using eddy-current type gap sensors those are fixed at a pump housing.

Evaluation of the Effective Charge Density on Low Pressure Nanofiltration with the Separation Characteristics of Monovalent and Divalent Solutes in the Production of Drinking Water

  • Oh, Jeong-Ik;Taro, Urase
    • Environmental Engineering Research
    • /
    • 제16권1호
    • /
    • pp.29-34
    • /
    • 2011
  • The electric charge on a membrane was investigated by analyzing the experimental rejection of various monovalent and divalent ionic solutes. The characteristics of the separation of ionic solutes using various nanofiltration membranes were obtained from an experimental nanofiltration set-up, with a surface area of $40cm^2$ under the operational pressures between 0.25-0.3 MPa. The state of the membrane electric charge was observed using separation coefficients, i.e., the permeation ratio of monovalent to divalent ions. To confirm the state of the membrane charge observed via the separation coefficient, a calculation using the extended Nernst-Planck equation, coupled with the Donnan equilibrium, assuming different electric charge states of the membrane, was compared with the experimental rejection of ionic solutes. The examination of the characteristics of separation using three types of nanofiltration membranes showed that one of the membranes carried a negative/positive double charge density inside, while other two membranes carried either a positive or negative charge density.

A study on Defect Control of Al-12%Si Alloy by Partial Squeeze Die Casting Method (스퀴즈 병용 다이캐스팅법에 의한 Al-12%Si 합금의 결함제어에 관한 연구)

  • Kim, Ok-Soo;Kim, Yong-Hyun;Lee, Kwang-Hak;Kim, Heung-Sik
    • Journal of Korea Foundry Society
    • /
    • 제15권4호
    • /
    • pp.377-387
    • /
    • 1995
  • Partial squeeze die casting is a special die casting process which combines squeeze technique to conventional die casting. The influence of squeeze pressure $(1500-3000kg/cm^2)$ and time-lags(0.5-2.0sec) on defect control, density and microstructure of ADC12 alloy die casts has been studied by appling partial squeeze die casting to air compressure front housing production. Defect free, maximum density of $2.736kg/cm^3$ with sound microstructure of ADC12 alloy die cast has been obtained by partial squeeze die casting technique at the pressure of $2000-2500kg/cm^2$ and time-lags of 1.0-2.0sec.

  • PDF

Characteristics of Two Dimensional Flow in an Involute Gear Pump (인벌류트 기어펌프의 2차원 유동특성)

  • Kim, S.H.;Son, H.M.;Lee, J.C.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • 제8권2호
    • /
    • pp.36-41
    • /
    • 2011
  • Analysis of two-dimensional flow in an involute gear pump has been done by using FLUENT. Analysis extended to the turbulent flow includes the mass flow rate with functions of pressure difference between inlet and outlet, rotational velocities of involute gear, and clearances between tip of gear and housing. In general mass flow rate decreases with decreasing rotational velocity, and with increasing clearance and pressure difference. The flow rate efficiency of gear pump, which is defined with the theoretical flow rate, has been presented in terms of the above parameters.