• 제목/요약/키워드: pressure correction

검색결과 391건 처리시간 0.028초

비균질 수정을 사용한 타원완화모형 개발 (Development of Elliptic Relaxation Model With The Inhomogeneous Correction)

  • 전건호;최영돈;신종근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.815-818
    • /
    • 2002
  • The elliptic relaxation model(ERM) with the inhomogeneous correction intermediate between near wall with and far from the wall. The source of the ERM usually was appled quasi-homogeneous pressure-strain correlation in homogeneous situations. This formulation was easily applied to the linear model or non-linear pressure-strain model. It is observed that the boundary conditions of the relaxation operator dominate the homogeneous pressure-strain model in the near wall region. While looking at high-Reynolds number flows, it was found necessary to modify the effect of the relaxation operator throughout the log region by accounting for gradients of the flatness variable and turbulent length scales. These effects are kinematic blocking of the wall normal velocity fluctuation and pressure reflections from the surface. This model is wall distances and unit vectors which make the model applicable to flows boundary by a complex geometry. Inhomogeneous correction model is computed inertial and non-inertial channel flow These are compared DNS(Kim et at., Kristofffrsen & Andersson) for channel flow. The present model could be predicted well for rotating flows.

  • PDF

대경사를 지나는 천수 흐름에서 수정된 정수압의 효과 (Effect of Corrected Hydrostatic Pressure in Shallow-Water Flow over Large Slope)

  • 황승용
    • 한국수자원학회논문집
    • /
    • 제47권12호
    • /
    • pp.1177-1185
    • /
    • 2014
  • 대경사 수로의 부등류에 대해 적용될 수 있도록 수정된, 새로운 정수압 분포를 제시하였다. 이것을 천수방정식에 적용하여 대경사를 지나는 천수 흐름을 정확하게 해석할 수 있는 유한체적 모형을 개발하였다. 포물선형 융기의 배수에 대해 압력 수정이 고려된 모형에서 바닥 경사 생성항의 영향이 줄어들어 융기의 하류에서 도수의 진행 속도가 크게 감소되었다. 삼각형 턱을 지나는 댐 붕괴 흐름에 대한 모의에서 압력 수정항이 추가된 모형으로 디지털 영상분석에 의한 수면을 압력 수정이 고려되지 않은 경우에 비해 더 잘 포착할 수 있음을 확인하였다. 압력 수정항 덕분에, 턱에 반사되는 흐름은 줄어들고 월류는 늘어 모의 결과가 실험 결과에 잘 부합된다. 따라서 댐의 여수로나 해안의 처오름 등 실용적인 문제에 대한 이 모형의 적용성이 기대된다.

관단으로부터 미소 압력파의 반사에 관한 기초적 연구 (Fundamental stuyd on reflection phenomenon of weak pressure-wave from an open end of a pipe)

  • 김희동
    • 대한기계학회논문집B
    • /
    • 제22권5호
    • /
    • pp.618-626
    • /
    • 1998
  • This paper describes a series of fundamental studies on reflection and emission of weak pressure waves from an open end of a pipe. Acoustical theories which have been employed in the plane pressure waves inside a pipe are applied to the present study. The objective of the present study is to investigate the reflection or emission coefficient of pressure wave at an open end of a pipe, the length of open end correction, and the directivity characteristics of the pressure waves emitted from the pipe. The results show that the reflection coefficient of pressure wave at an open end and the length of open end correction decrease for the wave length of pressure wave to increase. It is also found that the reflection coefficient for a baffle plate at the exit of pipe is larger than that for no baffle plate.

변위센서를 이용한 적응적 PID제어기반 자동차 변속기 샤프트 교정시스템 (Car transmission shaft distortion correction system based on adaptive PID controller using displacement sensors)

  • 최상복;반상우;김기택
    • 센서학회지
    • /
    • 제19권5호
    • /
    • pp.375-384
    • /
    • 2010
  • In this paper, we proposed a new shaft distortion correction system having an adaptive PID controller using displacement sensors, which is adaptively reflecting variations of shaft strength owing to irregular heat treatment during an annealing process and sensitivity to the seasonal temperature changes. Generally, the shafts are annealed by heat treatment in order to enlarge the strength of the shaft, which causes an distortion of a shaft such as irregular bending of the shaft. In order to correct such a distortion of the shaft, a mechanical pressure is properly impacted to the distorted shaft. However, the strength of every shaft is different from each other owing to irregular annealing and seasonal temperature changes. Especially, the strength of a thin shaft such as a car transmission shaft is much more sensitive than that of a thick shaft. Therefore, it is very important for considering the strength of each shaft during correction of the car transmission shaft distortion in order to generate proper mechanical pressure. The conventional PID controller for the shaft distortion correction system does not consider each different strength of each shaft, which causes low productivity. Therefore, we proposed a new PID controller considering variations of shaft strength caused by seasonal temperature changes as well as irregular heat treatment and different cooling time. Three displacement sensors are used to measure a degree of distortion of the shaft at three different location. The proposed PID controller generates adaptively different coefficients according to different strength of each shaft using appropriately obtained pressure times from long-term experiments. Consequently, the proposed shaft distortion correction system increases the productivity about 30 % more than the conventional correction system in the real factory.

PRECONDITIONERS FOR THE PRESSURE-CORRECTION METHOD APPLIED TO THE UNSTEADY STOKES PROBLEM

  • Ghahreman, N.;Kerayechian, A.
    • Journal of applied mathematics & informatics
    • /
    • 제16권1_2호
    • /
    • pp.307-321
    • /
    • 2004
  • In this paper, the unsteady Stokes problem is considered and also the pressure-correction method for the problem is described. At a fixed time level, we reduce the problem to two symmetric positive definite problems which depend on a time step parameter. Linear systems that arise from the problems are large, sparse, symmetric, positive definite and ill-conditioned as the time step tends to zero. Preconditioned problems based on an additive Schwarz method for solving the symmetric positive definite problems are derived and preconditioners are defined implicitly. It will be shown that the rate of convergence is independent of the mesh parameters as well as the time step size.

A CLASSIFICATION OF THE SECOND ORDER PROJECTION METHODS TO SOLVE THE NAVIER-STOKES EQUATIONS

  • Pyo, Jae-Hong
    • Korean Journal of Mathematics
    • /
    • 제22권4호
    • /
    • pp.645-658
    • /
    • 2014
  • Many projection methods have been progressively constructed to find more accurate and efficient solution of the Navier-Stokes equations. In this paper, we consider most recently constructed projection methods: the pressure correction method, the gauge method, the consistent splitting method, the Gauge-Uzawa method, and the stabilized Gauge-Uzawa method. Each method has different background and theoretical proof. We prove equivalentness of the pressure correction method and the stabilized Gauge-Uzawa method. Also we will obtain that the Gauge-Uzawa method is equivalent to the gauge method and the consistent splitting method. We gather theoretical results of them and conclude that the results are also valid on other equivalent methods.

불교란 화강토의 강도정수 (c,ø) 및 Dilatancy 보정 (Strength Parameter (c,ø) and Dilatancy Correction of Undisturbed Weathered Granite Soil)

  • 정진섭;양재혁
    • 한국농공학회지
    • /
    • 제42권6호
    • /
    • pp.106-114
    • /
    • 2000
  • In order to evaluate the shear characteristics of undisturbed weathered granite soil which is a typical residual soil in Korea, the mechanical properties are first investigated and discussed by carrying out a series of direct shear test and then dilatancy correction is performed by using Taylor’s correction equation. In this study, specimens are sampled at Pungam(-3, -8, -13m below ground surface), Kwangju and Iksan(-5m below ground surface), Jeonbuk. The test results are summarized as follows: 1) Mohr-Coulomb failure criterion is not linear under the low confining pressure. 2) The value of cohesion is smaller than usually determined value in low pressure region. 3) The value of strength parameter c and ø which are corrected by Taylor’s correction equation is a little bit small.

  • PDF

폐쇄형 풍동 시험부 내의 비정상 흐름에 대한 Blockage 보정 기법 연구 (Blockage-Correction Method for Unsteady Flows in a Closed Test-Section Wind Tunnel)

  • 강승희;권오준;안승기
    • 한국항공우주학회지
    • /
    • 제34권12호
    • /
    • pp.67-74
    • /
    • 2006
  • 아음속풍동 폐쇄형 시험부내의 비정상 벽면효과 보정 연구의 일환으로 시험부 벽면압력을 사용하는 비정상 흐름에 대한 blockage 보정 기법을 개발하였다. 시험부 벽면압력은 프리에 급수로 전개하고, 전개된 각 계수를 벽면압력측정 방법을 사용하여 전 주기에 대해 일괄적으로 보정하는 준 정상상태 보정 방법을 제시하였다. 본 연구에서 제시된 방법을 검증하기 위해 수치적으로 계산된 폐쇄형 시험부내의 원형실린더 및 강제 진동하는 익형의 비정상 흐름에 적용하였다. 그 결과 본 연구에서 제시된 방법은 자유흐름 상태와 일치되는 blockage 보정 결과를 보임을 확인하였다.

스파크 플러그형 압력센서에서 연결관로의 동적특성과 압력왜곡의 보상에 관한 연구 (A study on dynamic characteristics in extension tube and correction of pressure distortion for a S/P type pressure transducer)

  • 한승국;김승수
    • 오토저널
    • /
    • 제13권3호
    • /
    • pp.32-42
    • /
    • 1991
  • In SI engine research the pressure data in cylinder is the most important fundamental ones leading to engine efficiencies and performances. It is, therefore, necessary to obtain accurate pressure data and yet it is often impossible to install a reliable data producing, flush-mounted type pressure transducer in a cylinder of small and medium size multicylinder SI engines. When flush mounting the transducer is not possible, the spark-plug type pressure transducer is commonly used as an alternative. In this case, the transmission tube of spark-plug type pressure transducer introduces distortions in the pressure signal. Efforts were made to understand the dynamic characteristics of spark-plug pressure transducer by shock tube tests and real engine experiments. In engine experiment the cylinder pressure data were simultaneously obtained by both flush mounted and spark-plug type pressure transducers of certain transmission tube geometry. Those pressure data collected by spark-plug type pressure transducer were tested for correction to flush mounted ones by the application of transfer function. As a result of the calibration the IMEP difference between F/M data and improved S/P data was shown to be corrected about 75-98% from the original ones.

  • PDF

선천성 대동맥 축착증 4례 (Successful Correction of Atypical Coarctation of the Aorta -Report of 4 Cases-)

  • 권중혁
    • Journal of Chest Surgery
    • /
    • 제12권3호
    • /
    • pp.174-182
    • /
    • 1979
  • This is a report on four cases of successful surgical correction of coarctation of the aorta [COA] in Department of the Thoracic & Cardiovascular Surgery, Hanyang University Hospital. The first case was a postductal type of coarctation of the aorta associated with Patent ductus arteriosus [PDA], Persistent left superior vena cava [LSVC] and richly developed collateral circulation. Blood pressure was measured to be hypertensive at the arm, but hypotensive at the legs. The coarctation of the aorta was corrected with following procedure: Partial resection of the aortic wall with diaphragmatic structure lust above and below the coarctating line of the aorta, and then the defect of the aortic wall was closed by lateral aortographic suture. PDA was closed by ligation procedure. The second case a preductal type of coarctation of the aorta associated with PDA, LSVC, ventricular septal defect [VSD] and poorly developed collateral circulation. Normal blood pressure was measured at the arm, but hypotension was observed at the legs. Correction of coarctation of the aorta was performed under the establishment of tube bypass because of poor collateral circulation. After resection of coarctating short segment, end to end anastomosis was performed without any tension. PDA was closed by division procedure. Simple suture closure of VSD was performed by open heart surgery two weeks after correction of COA. The third case was a long segment COA without any other anomaly. Blood pressure was measured to be hypertensive at the arm, but hypotensive at the legs. Vascular prosthesis was performed using Teflon graft tube after resecting coarctating long segment [6.5 cm] of the aorta. The fourth case was a long segment COA associated with aortic insufficiency and richly developed collateral circulation. Normal blood pressure was measured at the arm, but hypotension was observed at the legs. Vascular prosthesis was performed using Teflon graft tube after resecting coarctating long segment [6.0 cm] of the aorta. Both blood pressure and peripheral pulse on the arm and the legs returned to normal postoperatively in all patients.

  • PDF