• Title/Summary/Keyword: preset

Search Result 206, Processing Time 0.026 seconds

DEVELOPMENT OF A METHOD FOR CONTROLLING GAS CONCENTRATION FOR USE IN C.A EXPERIMENTS

  • Yun, H.S.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.662-669
    • /
    • 2000
  • Based on the viscous flow characteristics of gas through capillary tube, a simple and low cost system was developed for controlling gas concentration for use in C.A experiments. The gas flow rate through capillary tube had a linear relationship with pressure, $(length)^{-1}$ and $(radius)^4$ of capillary tube, which agreed well with Hagen-Poiseuille's law. The developed system could control the gas concentration in storage chamber within ${\pm}0.3%$ deviation compared to the preset concentration. The required time for producing target gas concentration in storage chamber was exactly predicted by the model used in this study, and it required much longer time than the calculated time which divided the volume of chamber by flow rate. Therefore, for producing target gas concentration as quickly as possible, it needs to supply higher flow rate of gas during the initial stage of experiment when gas concentration in storage chamber has not reached at target value. It appeared that the developed system was very useful for C.A experiments. Because one could decide a desired flow rate by the prediction model, control flow rate freely and easily by changing pressure in the pressure-regulating chamber and the accuracy was high.

  • PDF

The Development of Anti-Windup Scheme for Time Delay Control with Switching Action Using Integral Sliding Surface (적분형 슬라이딩 서피스를 이용한 TDCSA(Time Delay Control With Switching Action)의 와인드업 방지를 위한 기법의 개발)

  • Lee, Seong-Uk;Jang, Pyeong-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1534-1544
    • /
    • 2002
  • The TDCSA(Time Delay Control with Switching Action) method, which consists of Time Delay Control(TDC) and a switching action of sliding mode control(SMC), has been proposed as a promising technique in the robust control area, where the plant has unknown dynamics with parameter variations and substantial disturbances are preset. When TDCSA is applied to the plant with saturation nonlinearity, however, the so-called windup phenomena are observed to arise, causing excessive overshoot and instability. The integral element of TDCSA and the saturation element of a plant cause the windup phenomena. There are two integral effects in TDCSA. One is the integral effect occurred by time delay estimation of TDC. Other is the integral term of an integral sliding surface. In order to solve this problem, we have proposed an anti-windup scheme method for TDCSA. The stability of the overall system has been proved for a class of nonlinear system. Experiment results show that the proposed method overcomes the windup problem of the TDCSA.

Performances of Hot Gas Bypass Type Oil Cooler System (Hot Gas를 이용한 오일쿨러의 성능평가)

  • Lee, Seung-Woo;Yeom, Han-Kil;Park, Kil-Jong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.3
    • /
    • pp.73-80
    • /
    • 2009
  • In accordance with the trend for high-speed multi-axes, and the increasing technical sophistication of machine tools, thermal deformation has become an important factor in the accuracy of machine tools. It was analyzed that thermal deformation error accounts for about 70% of all errors made with machine tools. For precise temperature control, both cooling and heating should be implemented. A hot gas bypass type cooling cycle method has a simplified structure and temperature control accuracy to with in ${\pm}0.1^{\circ}C$. In this study, the performances of oil cooler system, including temperature controllability according to hot gas floe and preset temperature sustainability according to temperature load, were tested. It is expected that this study will contribute to the development and performances of oil cooler system, which could minimize thermal errors and improve the quality of precision machine tools.

High Performance On Off Angle Control of SRM Using Linear Encoder (선형 엔코더를 이용한 SRM의 고정밀 온, 오프 각 제어)

  • Lee, Yeong-Jin;Park, Seong-Jun;Park, Han-Ung;Lee, Man-Hyeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.12
    • /
    • pp.61-67
    • /
    • 2000
  • In switched reluctance motor(SRM) drive, it is necessary to synchronize the stator phase excitation with the rotor position. Therefore the rotor position information is an essential. Usually optical encoders or resolvers are used to provide the rotor position information. These sensors are expensive and are not suitable for high speed operation. In general, the accuracy of the switching angle is dependent upon the resolution of the encoder and the sampling period of the microprocessor. But the region of high speed, switching angles are fluctuated back and forth from the preset values, which are cause by the sampling period of the microprocessor. Therefore, the low cost linear encoder suitable for the practical and stable SRM drive is proposed and the control algorithm to provide the switching signals using the simple digital logic circuit is also presented in this paper. It is verified from the experiments that the proposed encoder and logic controller can be a powerful candidate for the practical low cost SRM drive.

  • PDF

The Study on the New Encoder for High Performance Exciting Angle Control (SRM의 고정도 여자각 제어를 위한 새로운 엔코더)

  • Jung, Keum-Young;Park, Sung-Jun;Lee, Man-Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.4
    • /
    • pp.319-326
    • /
    • 2002
  • In switched reluctance motor(SRM) drive, it is important to synchronize the stator phase excitation with the rotor position; therefore, the information about rotor position is essential. Generally, optical encoders or resolvers are used to provide the information. However, these sensors are expensive and are not suitable for high-speed operation. The accuracy of the switching angles is dependent upon the resolution of the encoder and the sampling period of the microprocessor. In the high-speed region, switching angles are fluctuated back and forth out of the preset value, which is caused by the sampling period of the microprocessor. In this paper, a low cost linear encoder suitable far the practical and stable SRM drive is proposed and also the control algorithm to generate the switching signals using a simple digital logic is presented. The validity of the proposed linear encoder with a proper logic controller is verified through the experiments.

A Study on Noise Reduction Characteristics of Active Noise Controller Using Hysteresis Control Method (히스테리시스 제어 방식을 이용한 능동 소음 제어기의 소음저감 특성에 관한 연구)

  • 이승요;김홍성;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.35-40
    • /
    • 1997
  • The hysteresis control method has been frequently used for current control of power conversion equipments or motor drive systems. This method makes the measured signal follow the reference signal by changing the control signal whenever the error signal exceeds the preset band width. In this paper, hysteresis control method with fast response characteristics is applied for active noise control to suppress acoustic noise. Both Pentium processor and sound blaster 16 are used for experimental implementation, which executes A/D, D/A conversion and also is used as operating source of loudspeaker for audible noise cancellation.

  • PDF

In vitro Conservation of Coleus forskohlii- an Endangered Medicinal Plant

  • Rajasekharan P.E.;Ambika S.R.;Ganeshan S.
    • Journal of Plant Biotechnology
    • /
    • v.7 no.2
    • /
    • pp.135-141
    • /
    • 2005
  • Protocols for in vitro conservation was developed for Coleus forskohlii. Plants maintained both in field served as explant source. Shoot tips and single node cuttings were used to optimize protocols for in vitro multiplication. MS basal medium supplemented with $0.54\;{\mu}M$ naphthalene acetic acid (NAA) and $8.87\;{\mu}M$ benzy-ladenine (BA) induced multiple shoots in shoot tips and nodes. Shoot multiplication was amplified with a gradual decrease of BA concentration, leading to its final omission after 4 months. Concomitant rooting on multiplication media enabled successful establishment extra vitrum. For in vitro conservation studies, experiments were carried out with 2-3 week maintained in vitro plants under standard and reduced culture conditions (SCC, RCC). In vitro plants could be successfully conserved in full strength MS medium (FMS) under SCC for 6 months without subculture with full potential to regenerate, producing viable shoots and nodes. The root production remained unaffected due to conservation, showing high rooting activity in mannitol and low temperature treatments. Preset low temperature (15 and $10^{\circ}C$) and reduction in media constituents does not appear to favour conservation, although the former accomplished conservation levels equal to (FMS) under SCC.

A Wide Speed Operation of SRM Using Low Cost Encoder and Controller

  • Lee, young-Jin;Prak, Sung-Jun;Park, Han-Woong;Lee, Man-Hyung
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.1
    • /
    • pp.33-42
    • /
    • 2001
  • In switched reluctance motor(SRM) deives, the turn-on and turn-off angles of each phase switch should be accurately controlled for accuracy and efficiency. The accuracy of the switching angles is mainly dependent upon the resolution of the encoder and the sampling period of the microprocessor, that are used to provide the information of the rotor position and to implement a control algorithm of the SRM, respectively. Thus, the higher the speed of the SRM is increased, the larger the amount of the switching angle deviations are from preset turn-on and turn-off angles. Consequently, the motor can not be driven stably high speed region. There fore, a simples and low cost encoder suitable for the practical and stable SRM drive is proposed and the control algorithm to provide the switching signals using a simple digital logic circuit is also presented for a wide speed range operation.

  • PDF

Hydraulic Model Tests for the Distribution of Wave Height around the Ieodo Underwater Rocks (이어도 주변 파고분포에 대한 수리모형실험)

  • Chun Insik;Shim Jae-Seol
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.1
    • /
    • pp.55-59
    • /
    • 2005
  • The present data concerns the wave height distribution around the Ieodo underwater rocks and it was obtained from a 3D hydraulic model experiment which was performed in 1999 by Konkuk University and Korea Ocean Research and Development Institute. The experiment was separately undertaken for 4 different wave directions (NNW, SE, S, NNW) under which wave heights were measured at every 1m interval within the preset grid area, 16m×18m. It was observed that the wave breaking occurred on the top of the Ieodo model for all wave directions. This data may be effectively used for improving or verifying the performance of numerical wave propagation models in the area with the local breaking wave zones.

Advanced DC Offset Removal Filter of High-order Configuration (고차 구성의 개선된 직류 옵셋 제거 필터)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.12-17
    • /
    • 2013
  • Fault currents are expressed as a combination of harmonic components and exponentially decaying DC offset components, during the occurrence of fault in power system. The DC offset components are included, when the voltage phase angle of fault inception is closer to $0^{\circ}$ or $180^{\circ}$. The digital protection relay should be detected quickly and accurately during the faults, despite of the distortions of relaying signal by these components. It is very important to implement the robust protection algorithm, that is not affected by DC offset and harmonic components, because most relaying algorithms extract the fundamental frequency component from distorted relaying signal. So, In order to high performance in relaying, advanced DC offset removal filter is required. In this paper, a new DC offset removal filter, which is no need to preset a time constant of power system and accurately estimate the DC offset components with one cycle of data, is proposed, and compared with the other filter. In order to verify performance of the filter, we used collecting the current signals after synchronous machine modeling by ATPDraw5.7p4 software. The results of simulation, the proposed DC offset removal filter do not need any prior information, the phase delay and gain error were not occurred.