• 제목/요약/키워드: prefabricated system

검색결과 135건 처리시간 0.029초

강판 마감형 조립식 벽패널 복사냉난방시스템의 냉난방 방열 특성 평가 (Evaluation of Heating and Cooling Thermal Output Characteristics of Prefabricated Steel Wall Panel System for Radiant Heating and Cooling)

  • 임재한;구보경;김성임;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.70-77
    • /
    • 2013
  • Recently the radiant panel heating and cooling system has been regarded as an alternative of low temperature heating and high temperature cooling by applying the renewable energy sources to the heating and cooling of buildings. Especially this system can be used as HVAC system alternatives in super high-rise buildings for energy saving and thermal comfort. Also it can be possible to reduce the plenum space because the minimum ventilation air will be supplied into the space. This study focused on the evaluation the basic characteristics of thermal output in prefabricated steel wall panel system for radiant heating and cooling. In order to evaluate the thermal output according to both various supply water temperatures and supply water flow rates, three-dimensional dynamic heat transfer analysis was performed. As results, for the heating mode, thermal output increased by 26% with the supply temperature increasing by $5^{\circ}C$. The surface temperature of panels range within $1{\sim}3^{\circ}C$. For the cooling mode, thermal output decreased by 18.2% with the supply temperature increasing by $2^{\circ}C$. The surface temperature of panels range within $0.5{\sim}1^{\circ}C$ and it was shown the even temperature distribution.

연직배수재를 이용한 토양증기추출법의 적용 (Application of Enhanced Soil Vapor Extraction Using PVDs)

  • 신은철;박정준;김종인;최민근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.382-388
    • /
    • 2005
  • Soil vapor extraction(SVE) is an effective and cost efficient method of removing volatile organic compounds(VOCs) and petroleum hydrocarbons from unsaturated soils. However, soil vapor extraction becomes ineffective in soils with low gas permeability, for example soils with air permeabilities less than 1 Darcy. Prefabricated vertical drains(PVDs) have been used for dewatering fine-grained soils for more than 25 years. Incorporating PVDs in and SVE system can extend the effectiveness of SVE to lower permeability soils by shortening the air flow-paths and ultimately expediting contaminant removal. The objective of the work described herein was to effectively incorporate PVDs into a SVE remediation system and to demonstrate a PVDs enhanced SVE system at full scale. The finding from this research will facilitate the design of field PVD-SVE systems in terms by providing insight into the optimal spacing between PVDs, the radius of influence of the wells and the flow rates to be used to capture and extract gas phase contaminants.

  • PDF

컨테이너 하우스 외벽 구성 시스템 기술개발연구 (A Study on the Technical Development for the Exterior Wall System of Container House)

  • 김환식;백기영
    • 한국산학기술학회논문지
    • /
    • 제2권2호
    • /
    • pp.57-63
    • /
    • 2001
  • 본 연구는 기존 조적조 주택의 주요 구조부에 컨테이너를 활용한 개발 방식 즉, 컨테이너 하우스의 계획, 설계, 시공 가능한 시스템 개발을 목적으로 하였다. 이를 위해, 스틸하우스의 구조 및 시공 방법 등을 분석하였으며 컨테이너 하우스의 외벽 구성 시스템에 대한 견본품 제작을 완성하였다. 이 컨테이너 하우스 견본품을 토대로 두 개의 컨테이너 하우스 케이스 스터디에 적용하였고, 기존 조적조 주택 공법에 비하여 공사비 절감과 공기단축에 있어 현격한 효과가 있음을 확인하였다. 컨테이너하우스의 제작기술 개발 성공을 통해 스틸하우스 시장의 틈새 공략으로 기업체의 기술개발 및 투자방향을 제공하였다는데 의의가 있다.

  • PDF

기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교 (Comparison of removal torque between prefabricated and customized abutment screw)

  • ;김지환;김무성;박영범;심준성
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.243-248
    • /
    • 2012
  • 연구 목적: 본 연구의 목적은 임플란트 지대주 연결에 사용되는 기성품 나사와 맞춤형 나사의 풀림 토크를 비교하는 것이다. 연구 재료 및 방법: 세가지 임플란트 시스템에(Osstem, Astra, Zimmer) 대해 고정체와 지대주의 연결에 기성품 나사군(대조군)과 맞춤형 나사군(실험군)으로 총 6군(n = 6)으로 나누었다. 조임 토크조절은 디지털 토크 측정기를 이용하였으며 각 임플란트 제조사가 추천한 조임 토크 값을 적용하였다. 체결 10분 후 동일한 조임 토크를 다시 적용하고 5분 후에 풀림 토크력을 측정하였다. 이 과정을 10회 반복 측정하였다. 반복 하중 실험에서는 6개 군(n = 3)에 대해 체결 10분 후 2차 조임 토크를 적용하고 $30^{\circ}$ 경사로 50 N 하중으로 총 1,000,000번 반복 하중을 가하였다. 반복 하중 적용 이후 풀림 토크값을 측정하였다. 통계 방법으로는 10회 반복 측정에서 풀림 토크값의 차이를 비교하기 위해 repeated measures of ANOVA test (${\alpha}$=.05)를 사용하였고, 반복 하중 후 풀림 토크값의 차이를 비교하기 위해서 각 시스템별 Independant t-test로 통계 처리하였다. 결과: 모든 군에서 반복 횟수가 증가할수록 풀림 토크값이 유의성 있게 감소하는 것으로 나타났다(P<.05). 10회 반복 측정 실험에서는 세 종류의 임플란트에서 대조군(기성품나사)과 실험군(맞춤형 나사) 간에 풀림 토크값은 유의차가 없었다(P>.05). 반복 하중 실험에서 세가지 시스템에서 대조군과 실험군 간의 풀림 토크력은 유의한 차이가 없었다(P>.05). 결론: 반복 측정된 풀림력 검사와 반복 하중을 적용 후 풀림력 검사에서 맞춤형 나사와 기성품 나사의 풀림력은 유의한 차이가 없었다.

Cement Prefabricated Piped Making and Its Application on Agriculture Irrigation

  • Meng, Qingchang;Sun, Qingyi;Dang, Yongliang
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.212-218
    • /
    • 1996
  • The concrete pipe used to distribute irrigation water to the right place now available is commonly made up of cement , sand, earth, pebble, etc. These materials with right ratio and right amount of water were mixed and squeezed through the pipe-making machine called vertical squeezed pipe-making machine, and then a cement prefabricated pipe is produced . This kinds of pipe has been expanding by leaps and bounds. Being little cement contents and low cost, the length of pipe is 1.0m or so with weight of 50kg, which is easy to be made and to be transported. The demolish pressure of it is 0.2 MPa or so, which meets the needs of agriculture irrigation . The buried pipe irrigation system, has been popularized in Jining Municipal , Shandong Province. By the year of 1995 , the irrigation area under pipe conveyancesystem usign this type of pipe has reached 74000 hectares. By calculation, about 27.7million ㎥ water, 2.88 million kWh power , 0.167 million man power and 1528 hectares cu tivated land will be saved one year, adding value of agriculture output increased by 10 million kg. The total economic benefits amount to 0.92 million US$ a year. The paper presents the pipe making course and its application on a large scale area.

  • PDF

유닛모듈러 건축구조물의 수평 정밀도 확보를 위한 Pre-Fab 독립기초 높이조절 공법 개발 (Development of a Height Adjustment Method of Prefabricated Individual Footing for the Leveling of Unit Modular Structural System)

  • 전영훈;김균태;채명진
    • 한국건축시공학회지
    • /
    • 제15권6호
    • /
    • pp.631-639
    • /
    • 2015
  • 유닛모듈러 공법에서는 정밀 제작된 유닛모듈과 시공정밀도가 낮은 기초부의 접합부에서 수평 정밀도 차이가 발생한다. 이러한 정밀도 차이로 인하여 상부 유닛모듈이 뒤틀리거나, 간격이 벌어지는 등 다양한 문제가 야기될 수 있다. 이러한 배경에서 본 연구는 Pre-Fab 독립기초의 높이조절이 가능한 공법을 개발하는 것을 목적으로 하였다. 이를 위하여 본 연구에서는 볼트와 너트를 이용한 높이조절 공법을 제안하고 시공 상세도와 시공순서를 제시하였다. 그리고 구조 시뮬레이션을 수행하여 구조적 안정성을 확인하였다. 향후 개발된 높이조절 공법의 mock-up 시험, 경제성 분석 등을 실시하여 시공성과 유용성을 검토할 예정이다.

강재 요소를 적용한 조립식 흙막이 벽체에 관한 연구 (Application of Prefabricated Retaining Walls with Steel Lagging)

  • 홍종우;최재순
    • 대한토목학회논문집
    • /
    • 제35권6호
    • /
    • pp.1277-1285
    • /
    • 2015
  • H-pile과 목재 토류판을 사용하는 흙막이 공법은 오랜 기간 굴착공사에서 사용되어 온 공법이지만 H-pile 사이의 간격이 일정치 않아 규격화된 목재를 절단하거나 덧대기 공정이 추가되는 문제점이 있다. 또한, 시방규정상 3회 재사용을 위한 목재 회수시 안전사고의 위험이 따르게 되며 이러한 이유로 목재를 회수치 않고 지중에 매몰하여 여러 차례 방송매체의 지적을 받은 바 있다. 이 연구에서는 이상의 문제점을 보완하기 위하여 기존의 목재 토류판을 대신하여 강재 요소를 적용하는 방안을 제시하였다. 강재 흙막이 구조체는 자유 확폭과 개별 흙막이 구조체를 연결하는 커넥터를 통해 시공 편의성 및 재활용을 위한 회수가 가능한 것이 특징이다. 또한, 해체 시 커넥터를 통한 구조체간의 연결성으로 지중인력투입없이 해체가 가능하다. 이러한 흙막이 구조체의 강도특성을 분석하기 위해 UTM장비를 사용하여 휨 강성시험, 반복 사용의 능력을 확인하기위한 피로 강도시험, 그리고, 흙막이 구조체의 회수 시 연결부 구조체의 성능을 확인하기위한 인장 강도시험을 수행하였다. 또한, 장점으로 부각된 내용이 현장에서 실제 가능한지 여부를 확인하기 위한 현장시험과 다양한 지반조건에 따른 수치해석을 통해 현장 적용성을 평가하였다. 연구결과, 구조적 특성뿐만 아니라 설치 및 해체시의 시공 편의성이 매우 탁월한 것으로 나타났으며 향후 구조체의 재사용과 함께 시공 경제성 증진에도 크게 기여할 것으로 판단된다. 특히, 다단굴착시 굴착배면에 흙막이 구조체가 밀착되어 설치가 가능한 점은 기존 공법에서 지적되어 온 배면지반의 뒷채움 불량이 발생할 여지가 없어 시공 및 시공 후 시설물의 안전성 증진에 크게 기여할 수 있을 것으로 판단된다.

Performance evaluation of smart prefabricated concrete elements

  • Zonta, Daniele;Pozzi, Matteo;Bursi, Oreste S.
    • Smart Structures and Systems
    • /
    • 제3권4호
    • /
    • pp.475-494
    • /
    • 2007
  • This paper deals with the development of an innovative distributed construction system based on smart prefabricated concrete elements for the real-time condition assessment of civil infrastructure. So far, two reduced-scale prototypes have been produced, each consisting of a $0.2{\times}0.3{\times}5.6$ m RC beam specifically designed for permanent instrumentation with 8 long-gauge Fiber Optic Sensors (FOS) at the lower edge. The sensing system is Fiber Bragg Grating (FBG)-based and can measure finite displacements both static and dynamic with a sample frequency of 625 Hz per channel. The performance of the system underwent validation in the laboratory. The scope of the experiment was to correlate changes in the dynamic response of the beams with different damage scenarios, using a direct modal strain approach. Each specimen was dynamically characterized in the undamaged state and in various damage conditions, simulating different cracking levels and recurrent deterioration scenarios, including cover spalling and corrosion of the reinforcement. The location and the extent of damage are evaluated by calculating damage indices which take account of changes in frequency and in strain-mode-shapes. The outcomes of the experiment demonstrate how the damage distribution detected by the system is fully compatible with the damage extent appraised by inspection.