Accuracy of Spirometry at Predicting Restrictive Pulmonary Impairment (제한성 환기장애의 진단에서 폐활량검사의 정확성)

  • Ahn, Young Mee;Koh, Won-Jung;Kim, Cheol Hong;Lim, Seong Yong;An, Chang Hyeok;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.3
    • /
    • pp.330-337
    • /
    • 2003
  • Background : Low spirometric forced vital capacity(FVC) in conjunction with a normal or high ratio of the forced expiratory volume at 1 second to the forced vital capacity($FEV_1$/FVC%) has traditionally been classified as a restrictive abnormality. However, the gold-standard diagnosis of a restrictive pulmonary impairment requires a measurement of the total lung capacity (TLC). This study was performed to determine the predictive value of spirometric measurements of the FVC for diagnosing a restrictive pulmonary abnormality. Methods : Test results from 1,371 adult patients who undertook both spirometry and lung volume measurements on the same visit from January 1999 to December 2000 were enrolled in this study. The test values for the FVC, the TLC that was below 80% of predicted value, and a $FEV_1$/FVC% that was below 70%, were classified as being abnormal. Results : Of the 1,371 patients, 353 patients had a reduced a FVC. Of these patients, 186 patients had a reduced TLC. Therefore, the positive predictive value was 52.7%. Of the 196 patients with a normal $FEV_1$/FVC% and a reduced FVC, 148(75.5%) patients had a lower TLC. Thirty eight (24.2%) patients out of 157 patients with a low $FEV_1$/FVC% and a low FVC showed a restrictive defect. Conclusion : Spirometry is useful to rule out a restrictive pulmonary abnormality, but a restrictive pattern on the spirometry dose not mean there is a true restrictive disease. For the patients with a low FVC, TLC measurements are essential for diagnosing a restrictive pulmonary impairment.

Evaluation of a Rapid Diagnostic Antigen Test Kit Ribotest Mycoplasma® for the Detection of Mycoplasma pneumoniae (Mycoplasma pneumoniae 감염의 신속 항원 검사 키트 "Ribotest Mycoplasma®"의 진단적 평가)

  • Yang, Song I;Han, Mi Seon;Kim, Sun Jung;Lee, Seong Yeon;Choi, Eun Hwa
    • Pediatric Infection and Vaccine
    • /
    • v.26 no.2
    • /
    • pp.81-88
    • /
    • 2019
  • Purpose: Early detection of Mycoplasma pneumoniae is important for appropriate antimicrobial therapy in children with pneumonia. This study aimed to evaluate the diagnostic value of a rapid antigen test kit in detecting M. pneumoniae from respiratory specimens in children with lower respiratory tract infection (LRTI). Methods: A total of 215 nasopharyngeal aspirates (NPAs) were selected from a pool of NPAs that had been obtained from children admitted for LRTI from August 2010 to August 2018. The specimens had been tested for M. pneumoniae by culture and stored at $-70^{\circ}C$ until use. Tests with Ribotest $Mycoplasma^{(R)}$ were performed and interpreted independently by two investigators who were blinded to the culture results. Results: Among the 215 NPAs, 119 were culture positive for M. pneumoniae and 96 were culture negative. Of the culture-positive specimens, 74 (62.2%) were positive for M. pneumoniae by Ribotest $Mycoplasma^{(R)}$, and 92 of the 96 (95.8%) culture-negative specimens were negative for M. pneumoniae by Ribotest $Mycoplasma^{(R)}$. When culture was used as the standard test, the sensitivity and specificity of Ribotest $Mycoplasma^{(R)}$ were 62.2% and 95.8%, respectively. Additionally, the positive predictive value, negative predictive value, and overall agreement rates with Ribotest $Mycoplasma^{(R)}$ were 94.9%, 67.2%, and 77.2%, respectively. Conclusions: A positive test result of Ribotest $Mycoplasma^{(R)}$ suggests a high likelihood of culture-positive M. pneumoniae infection. However, a negative test result should be interpreted with caution because nearly one-third of negative test results reveal culture-positive M. pneumoniae infections.

Optimization of Organosolv Pretreatment of Waste Wood for Lignin Extraction (폐목재로부터 리그닌 추출을 위한 Organosolv 전처리공정의 최적화)

  • Lee, Hyunsu;Kim, Young Mo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.10
    • /
    • pp.568-574
    • /
    • 2017
  • The purpose of this study was to optimize experimental conditions (time ($X_1$) (ranging of 26.36 - 93.64 min), concentration of sulfuric acid ($X_2$) (ranging of 0-2.5%) and temperature ($X_3$) (ranging of $136.4-203.6^{\circ}C$) for an organosolv pretreatment process to extract lignin from waste wood. The resulting quadratic model equation using RSM (response surface methodology) represented y (lignin yield) = $-79.89+0.91X_1+9.8X_2-2.54{\times}10^{-3}X_1{^2}-2.11X_2{^2}$. The $R^2$ (coefficient of determination) value of 0.8531 for a model indicates this model has statistically significant predictors at the 10% levels. The predictive results optimized by quadratic model produced a lignin yield of 12.46 g/100 g of dry wood under conditions of $178.2^{\circ}C$ and 2.32% $H_2SO_4$. The lignin yield was more affected by the acid catalyst concentrations than the reaction temperature, but the reaction time was not an influential factor for improving lignin extraction from waste wood in this organosolv pretreatment. According to ANOVA (analysis of variance), the significance probability (p-value) of model was smaller than 0.001 and simulation of obtained model equations showed a good reproducibility based on actual organosolv tests under optimal conditions.

The Etiologic Diseases and Diagnostic Usefulness of Color Doppler Ultrasonography in Children with Chronic Coughs (소아 만성 기침의 원인 질환과 컬러 도플러 초음파 검사의 진단적 유용성)

  • Park, Sun Young;Lee, Joon Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.489-497
    • /
    • 2002
  • Purpose : The objectives of this study were to investigate the causes of chronic cough and to establish the appropriate diagnostic approach to chronic cough in children. Methods : One hundred and thirty two cases of chronic cough were prospectively evaluated. They visitors to pediatric chronic cough clinics at Kang-nam saint Mary's Hospital of Catholic University from August 2000 to July 2001 for 12 months. Careful history taking by questionnaire, physical examination, radiologic studies of chest and sinus, hematologic and immunologic studies, allergic skin tests, and methacholine challenge tests were performed. Color doppler(CD) ultrasonography were performed and compared with simultaneous 24 Hr. esophageal pH monitoring to diagnose gastroesophageal reflux disease(GERD). Results : Age distributions were demonstrated that nine in infants, 82 in early childhood, 38 in late childhood, and three in adolescence. Common causes of chronic cough were bronchial asthma in 40 cases, chronic sinusitis in 22 cases, GERD in seven cases, bronchial asthma combined with sinusitis in 28 cases, bronchial asthma combined with GERD in 14 cases, psychogenic cough in two. cases, foreign body in one case, chronic bronchitis in one case, and bronchiolitis in one case. Comparing with 24 Hr. pH monitoring, sensitivity, specificity, positive predictive value and negative predictive values of CD ultrasonography were 88%, 69%, 85 %, and 73% respectively. Conclusion : The most common causes of chronic cough in children were bronchial asthma, sinusitis and GERD in order. We suggest that CD ultrasonography can be used as a good, convenient screening method for patients with suspected GERD in outpatient settings.

The Usefulness of Serologic Diagnosis for Tuberculosis with Two Rapid Immunochromatographic Assay Devices (혈청학적 방법을 이용한 결핵 진단 방법의 효용성)

  • Kim, Deog-Kyeom;Kwon, Sung-Youn;Lee, Suk-Young;Park, Gye-Young;Jung, Kyung-Hae;Lee, Chun-Taek;Yoo, Churl-Gyoo;Kim, Young-Whan;Han, Sung-Koo;Shim, Yong-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.586-597
    • /
    • 1999
  • Background: Many diagnostic tests have developed to diagnose tuberculosis and other mycobacterial diseases but the diagnosis of tuberculosis relies largely on radiological findings and acid-fast staining of sputum and/or culture. Recently, new serologic diagnostic methods, which are safe and easy to use have been introduced into Korea. In this study, the usefulness of serologic diagnosis for tuberculosis and the disease pattern induced variation of the test were evaluated. Methods: Serological assay was performed upon 108 patients with two test kits, the ICT tuberculosis and the BioSign$^{TM}$TB, which are based upon a rapid immunochromatographic assay technique, capable of being interpreted within 15 minutes. The case groups consisted of 61 patients with active pulmonary tuberculosis(36 patients), extrapulmonary tuberculosis(3 patients), or both(22 patients). Control groups consisted of 47 patients with inactive old pulmonary tuberculosis(17 patients), nontuberculous pulmonary disease(16 patients) and nonpulmonary cardiac disease(14 patients). Results : The diagnostic sensitivity, specificity, positive predictive value(PPV) and negative predictive value(NPV) of the ICT tuberculosis were 64.3%, 91.5%, 90.0% and 68.3% respectively. The diagnostic sensitivity, specificity, PPV and NPV of the BioSign$^{TM}$TB were 76.5%, 95.3%, 94.1 % and 78.8% respectively. Differences in sensitivity were not significant between patients with previous history of tuberculosis or patients without prior history of tuberculosis. The ICT tuberculosis test showed higher sensitivity in pulmonary tuberculosis patients(76.5%) than extrapulmonary tuberculosis patients(33.3%). There was no difference in sensitivity between patients with or without cavitary lesion by chest X-ray. Conclusion: Considering high specificity and PPV, serologic diagnosis using a rapid immunochromatographic assay device is another helpful diagnostic method in the diagnosis of tuberculosis, when combined with previous diagnostic methods such as chest X-ray, microbiologic study but it has limitation in terms of confirming the diagnosis for tuberculosis as the only diagnostic method because of relatively low sensitivity and NPV.

  • PDF

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

Can the C-14 Urea Breath Test Reflect the Extent and Degree of Ongoing Helicobacter pylori Infection? (C-14 요소호기검사의 정량치가 Helicobacter pylori 감염 정도를 반영할 수 있을까?)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok;Lee, Soo-Teik;Jeong, Myoung-Ja
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.61-68
    • /
    • 2001
  • Purpose: The C-14 urea breath test (C-14 UBT) is the most specific noninvasive method to detect Helicobacter (H) pylori infection. We investigated if the C-14 UBT can reflect the presence and degree of H. pylori detected by gastroduodenoscopic biopsies (GBx). Materials and methods: One hundred fifty patients (M:F=83:67, age $48.6{\pm}11.2$ yrs) underwent C-14 UBT, rapid urease test (CLO test) and GBx on the same day. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (137 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (${\geq}200dpm$), Intermediate ($50{\sim}199dpm$) or negative (<50 dpm). The results of CLO tests were classified as positive or negative according to color change. The results of GBx on giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT results with GBx grade as a gold standard. Results: In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.5%, 88.4%, 97.1%, 88.4% and 91.3%, respectively. However, the CLO test had sensitivity, specificity, PPV, NPV and accuracy of 83.2%, 81.4%, 91.8%, 81.4% and 82.7%, respectively. The quantitative values of the C-14 UBT were $45{\pm}27$ dpm in grade 0, $707{\pm}584dpm$ in grade 1, $1558{\pm}584dpm$ in grade 2, $1851{\pm}604dpm$ in grade 3, and $2719{\pm}892dpm$ in grade 4. A significant correlation (r=0.848, p<0.01) was found between C-14 UBT and the grade of distribution of H. pylori infection on GBx with giemsa stain. Conclusion: We conclude that the C-14 UBT is a highly accurate, simple and noninvasive method for the diagnosis of ongoing H. pylori infection and reflects the degree of bacterial distribution.

  • PDF

Study of Serious Bacterial Infections in Febrile Infants Younger than Three Months of Age (열이 있는 3개월 이하의 영아에서 세균성 감염의 예측에 대한 연구)

  • Jeon, Myeoung Won;Lee, Ji Young;Jang, Young Taek
    • Pediatric Infection and Vaccine
    • /
    • v.10 no.2
    • /
    • pp.215-222
    • /
    • 2003
  • Purpose : This study was to analyze serious bacterial infections in infants younger than three months of age and to review the direction of treatments for these patients. Methods : 378 febrile infants with a rectal temperature ${\geq}38.0^{\circ}C$ visited from Jan. 2001 through Dec. 2002 were retrospectively studied. Infants with the following criteria belonged to the low risk group. WBC $5,000{\sim}15,000/mm^3$, WBC negative in urine stick test and negative for nitirite test, CSF WBC < $10/mm^3$ and negative in CSF gram stain, negative chest X-ray, stool WBC <5/HFP(high power field), and focal infection. If any of the above criteria were not met, they belonged to the high risk group. SBI was defined as a positive culture of urine, blood or CSF. SI was defined as aseptic meningitis or pneumonia including above laboratory tests of SBI. SBI patients were separately compared with two groups, high risk and low risk. Results : Of the 378 infants that were tested 216(57.1%) were in the high risk group and 162(42.9%) in the low risk group. Among 105 SBI(27.8%) and 172 SI(45.5%), there were 98 urinary tract infection(25.2%), 10 bacteremia(2.6%), 2 bacterial meningitis(0.6%), and 77 aseptic meningitis(22.8%). There were 76 SBI(35.2%) from the high risk group and 29 SBI(17.9%) from the low risk group identified. The results of the sensitivity(72.4%), the specificity(48.7%), the negative predictive value(82.1%) and the positive predictive value (35.2%) were calculated. Conclusion : Even though the probability of SBI in the low risk group is insignificant, it should still be considered in febrile infants younger than 3 months of age. I believe the CSF study is necessary because of the moderate high incidence of abnormal finding in our study.

  • PDF

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.

Effect of the Changing the Lower Limits of Normal and the Interpretative Strategies for Lung Function Tests (폐기능검사 해석에 정상하한치 변화와 새 해석흐름도가 미치는 영향)

  • Ra, Seung Won;Oh, Ji Seon;Hong, Sang-Bum;Shim, Tae Sun;Lim, Chae Man;Koh, Youn Suck;Lee, Sang Do;Kim, Woo Sung;Kim, Dong-Soon;Kim, Won Dong;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.2
    • /
    • pp.129-136
    • /
    • 2006
  • Background: To interpret lung function tests, it is necessary to determine the lower limits of normal (LLN) and to derive a consensus on the interpretative algorithm. '0.7 of LLN for the $FEV_1$/FVC' was suggested by the COPD International Guideline (GOLD) for defining obstructive disease. A consensus on a new interpretative algorithm was recently achieved by ATS/ERS in 2005. We evaluated the accuracy of '0.7 of LLN for the $FEV_1$/FVC' for diagnosing obstructive diseases, and we also determined the effect of the new algorithm on diagnosing ventilatory defects. Methods: We obtained the age, gender, height, weight, $FEV_1$, FVC, and $FEV_1$/FVC from 7362 subjects who underwent spirometry in 2005 at the Asan Medical Center, Korea. For diagnosing obstructive diseases, the accuracy of '0.7 of LLN for the $FEV_1$/FVC' was evaluated in reference to the $5^{th}$ percentile of the LLN. By applying the new algorithm, we determined how many more subjects should have lung volumes testing performed. Evaluation of 1611 patients who had lung volumes testing performed as well as spirometry during the period showed how many more subjects were diagnosed with obstructive diseases according to the new algorithm. Results: 1) The sensitivity of '0.7 of LLN for the $FEV_1$/FVC' for diagnosing obstructive diseases increased according to age, but the specificity was decreased according to age; the positive predictive value decreased, but the negative predictive value increased. 2) By applying the new algorithm, 34.5% (2540/7362) more subjects should have lung volumes testing performed. 3) By applying the new algorithm, 13% (205/1611) more subjects were diagnosed with obstructive diseases; these subjects corresponded to 30% (205/681) of the subjects who had been diagnosed with restrictive diseases by the old interpretative algorithm. Conclusion: The sensitivity and specificity of '0.7 of LLN for the $FEV_1$/FVC' for diagnosing obstructive diseases changes according to age. By applying the new interpretative algorithm, it was shown that more subjects should have lung volumes testing performed, and there was a higher probability of being diagnosed with obstructive diseases.