• Title/Summary/Keyword: preconditioning test

Search Result 34, Processing Time 0.023 seconds

Whole body hypoxic preconditioning-mediated multiorgan protection in db/db mice via nitric oxide-BDNF-GSK-3β-Nrf2 signaling pathway

  • Li, Yuefang;Huang, Yan;Cheng, Xi;He, Youjun;Hu, Xin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.4
    • /
    • pp.281-296
    • /
    • 2021
  • The beneficial effects of hypoxic preconditioning are abolished in the diabetes. The present study was designed to investigate the protective effects and mechanisms of repeated episodes of whole body hypoxic preconditioning (WBHP) in db/db mice. The protective effects of preconditioning were explored on diabetes-induced vascular dysfunction, cognitive impairment and ischemia-reperfusion (IR)-induced increase in myocardial injury. Sixteen-week old db/db (diabetic) and C57BL/6 (non-diabetic) mice were employed. There was a significant impairment in cognitive function (Morris Water Maze test), endothelial function (acetylcholine-induced relaxation in aortic rings) and a significant increase in IR-induced heart injury (Langendorff apparatus) in db/db mice. WBHP stimulus was given by exposing mice to four alternate cycles of low (8%) and normal air O2 for 10 min each. A single episode of WBHP failed to produce protection; however, two and three episodes of WBHP significantly produced beneficial effects on the heart, brain and blood vessels. There was a significant increase in the levels of brain-derived neurotrophic factor (BDNF) and nitric oxide (NO) in response to 3 episodes of WBHP. Moreover, pretreatment with the BDNF receptor, TrkB antagonist (ANA-12) and NO synthase inhibitor (L-NAME) attenuated the protective effects imparted by three episodes of WBHP. These pharmacological agents abolished WBHP-induced restoration of p-GSK-3β/GSK-3β ratio and Nrf2 levels in IR-subjected hearts. It is concluded that repeated episodes of WHBP attenuate cognitive impairment, vascular dysfunction and enhancement in IR-induced myocardial injury in diabetic mice be due to increase in NO and BDNF levels that may eventually activate GSK-3β and Nrf2 signaling pathway to confer protection.

BILUS: A BLOCK VERSION OF ILUS FACTORIZATION

  • Davod Khojasteh Salkuyeh;Faezeh Toutounian
    • Journal of applied mathematics & informatics
    • /
    • v.15 no.1_2
    • /
    • pp.299-312
    • /
    • 2004
  • ILUS factorization has many desirable properties such as its amenability to the skyline format, the ease with which stability may be monitored, and the possibility of constructing a preconditioner with symmetric structure. In this paper we introduce a new preconditioning technique for general sparse linear systems based on the ILUS factorization strategy. The resulting preconditioner has the same properties as the ILUS preconditioner. Some theoretical properties of the new preconditioner are discussed and numerical experiments on test matrices from the Harwell-Boeing collection are tested. Our results indicate that the new preconditioner is cheaper to construct than the ILUS preconditioner.

Preconditioned Compressible Navier- Stokes Algorithm for Low Mach Number Flows (예조건화 압축성 알고리즘에 의한 저마하수 유동장 해석기법)

  • Ko Hyun;Yoon Woong-Sup
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.05a
    • /
    • pp.35-42
    • /
    • 1998
  • Time marching algorithms applied to compressible Navier-Stokes equation have a convergence problem at low Mach number. It is mainly due to the eigenvalue stiffness and pressure singularity as Mach number approaches to zero. Among the several methods to overcome the shortcomings of time marching scheme, time derivative preconditioning method have been used successfully. In this numerical analysis, we adopted a preconditioner of K.H. Chen and developed a two-dimensional, axisymmetric Navier-Stokes program. The steady state driven cavity flow and backward facing step flow problems were computed to confirm the accuracy and the robustness of preconditioned algorithm for low Mach number flows. And the transonic and supersonic flows insice the JPL axisymmetric nozzle internal flow is exampled to investigate the effects of preconditioning at high Mach number flow regime. Test results showed excellent agreement with the experimental data.

  • PDF

Preconditioned Jacobian-free Newton-Krylov fully implicit high order WENO schemes and flux limiter methods for two-phase flow models

  • Zhou, Xiafeng;Zhong, Changming;Li, Zhongchun;Li, Fu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.49-60
    • /
    • 2022
  • Motivated by the high-resolution properties of high-order Weighted Essentially Non-Oscillatory (WENO) and flux limiter (FL) for steep-gradient problems and the robust convergence of Jacobian-free Newton-Krylov (JFNK) methods for nonlinear systems, the preconditioned JFNK fully implicit high-order WENO and FL schemes are proposed to solve the transient two-phase two-fluid models. Specially, the second-order fully-implicit BDF2 is used for the temporal operator and then the third-order WENO schemes and various flux limiters can be adopted to discrete the spatial operator. For the sake of the generalization of the finite-difference-based preconditioning acceleration methods and the excellent convergence to solve the complicated and various operational conditions, the random vector instead of the initial condition is skillfully chosen as the solving variables to obtain better sparsity pattern or more positions of non-zero elements in this paper. Finally, the WENO_JFNK and FL_JFNK codes are developed and then the two-phase steep-gradient problem, phase appearance/disappearance problem, U-tube problem and linear advection problem are tested to analyze the convergence, computational cost and efficiency in detailed. Numerical results show that WENO_JFNK and FL_JFNK can significantly reduce numerical diffusion and obtain better solutions than traditional methods. WENO_JFNK gives more stable and accurate solutions than FL_JFNK for the test problems and the proposed finite-difference-based preconditioning acceleration methods based on the random vector can significantly improve the convergence speed and efficiency.

Cardioprotective Effect by Preconditioning with Calcium-free Solution (칼슘결핍용액 투여 전처치에 의한 심근보호 효과)

  • 조대윤;이종화;김호덕
    • Journal of Chest Surgery
    • /
    • v.32 no.9
    • /
    • pp.773-780
    • /
    • 1999
  • Background: It has been demonstrated that brief periods of calcium depletion and repletion (calcium-free preconditioning, CP) have cardioprotective effects as seen in ischemic preconditioning(IP) which enhances the recovery of post-ischemic contractile dysfunction and reduces the incidence of reperfusion-induced arrhythmia or infarct size after a prolonged ischemia. In the present study, we tested this paradoxical phenomenon in isolated rabbit hearts. Material and Method: Hearts isolated from New Zealand white rabbits(1.5∼2.0 Kg body weight) were perfused with Tyrode solution using the Langendorff technique. After stabilizing the baseline hemodynamics, the hearts were subjected to 45 minutes of global ischemia followed by 120 minutes of reperfusion with IP(IP group, n=7) or without IP (ischemic control group, n=7). IP was induced by a single episode of 5 minutes global ischemia and 10 minutes reperfusion. In the CP group(n=7), the hearts were subjected to perfusion with Tyrode solution with calcium depletion for 5 minutes and repletion for 10 minutes, and 45 minutes of ischemia and 120 minutes of reperfusion. Left ventricular function including developed pressure, dP/dt, heart rate, left ventricular end-diastolic pressure and coronary flow was measured. Infarct size was determined by staining with 1% triphenyltetrazolium chloride and planimetry. Data were analyzed by a one-way analysis of variance and Tukey's post-hoc test. Result: In comparison with the ischemic control group, IP significantly enhanced the recovery of the left ventricular function including the left ventricular developed pressure, contractility, and coronary flow; in contrast, these functional parameters of the CP group tended to be lower than those of the ischemic control group. However, the infarct size was significantly reduced by IP or CP(p<0.05). Conclusion: These results suggest that in isolated Langendorff-perfused rabbit heart model, CP(induced by single episode of 5 minutes calcium depletion and 10 minutes repletion) could not improve the post-ischemic contractile dysfunction(after a 45-minute global ischemia) but it has an infarct size-limiting effect.

  • PDF

Hypothermic Preconditioning Lowers the Incidence of Hypothermic Arrest in Neonatal Rat

  • Park, Sung-Sook;Na, Heung-Sik;Nam, Hyun-Jung;Hong, Seung-Kil
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.2
    • /
    • pp.231-236
    • /
    • 1999
  • This study was performed to examine 1) Whether hypothermic cardiac arrest produces myocardial HSP72 expression; 2) And if, whether it serves to protect the heart against the subsequent hypothermic arrest. In the present study, neonatal rats were placed in an icebath to induce hypothermia. To determine whether hypothermic cardiac arrest produces myocardial HSP72, experimental animals were subjected to 10-min hypothermic insult before the extraction of the heart. The intervals between the insult and extraction were 1 (1 HR), 4 (4 HR), 8 (8 HR), 24 (24 HR) or 72 (72HR) hours. A minimal amount of HSP72 was detected in control, 1 HR and 72 HR groups. In contrast, 8 HR and 24 HR groups showed a significant level of HSP72 expressions. To assess the cardioprotective effect of HSP72 against hypothermic cardiac arrest, we compared the proportion of recovery from the arrest between control and preconditioned (PREC) animals. Control animals were subjected to 20-min hypothermic insult, while PREC group was preconditioned by 10-min hypothermic insult 8 hours before the 20-min test hypothermic insult. Resuscitation rate from cardiac arrest induced by the 20-min hypothermic insult in PREC group was significantly higher than that in controls. These results suggest that the cardioprotective effect of hypothermic preconditioning is associated with an increase in HSP72 expression.

  • PDF

The Analysis of Weibull Distribution after an Accelerated Aging Test of MV Cable (차수형 케이블의 수트리 가속실험후 와이블분포 해석)

  • Kim, Jin-Gook;Lim, Jang-Seob;Song, Il-Keun;Lee, Jae-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.178-181
    • /
    • 2003
  • For many years, testing laboratories, research institutes and manufactures try to find a reliable water tree accelerated ageing test that is able to show whether a polymer Medium Voltage cable os susceptible to water treeing or not. Test on laboratory samples, model cable designs, and fell size cable are presented Apart form aging, another important aspect of any accelerated aging test is the right choice of th preconditioning method. This paper is the analysis of weibull distribution method after an accelerated aging test of MV(Medium Voltage) cable.

  • PDF

The Analysis of Weibull Distribution after an Accelerated Aging Test of MV Cable (배전케이블의 수트리 가속열화 후 와이블분포 해석)

  • Kim, Jin-Gook;Lim, Jang-Seob;Song, Il-Gun;Kim, Ju-Yong;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.7-11
    • /
    • 2003
  • for many years already, testing laboratories, research institutes and manufactures try to find a reliable water tree accelerated ageing test that is able to show whether a polymer Medium Voltage cable os susceptible to water treeing or not. Test on laboratory samples, model cable designs, and fell size cable are presented. Apart form aging, another important aspect of any accelerated aging test is the right choice of th preconditioning method. THTS paper is the analysis of weibull distribution method after an accelerated aging test of MV(Medium Cable) cable.

  • PDF

Cardioprotective Effect of Calcium Preconditioning and Its Relation to Protein Kinase C in Isolated Perfused Rabbit Heart (적출관류 토끼 심장에서 칼슘 전처치에 의한 심근보호 효과와 Protein Kinase C와의 관계)

  • 김용한;손동섭;조대윤;양기민;김호덕
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.603-612
    • /
    • 1999
  • Background : It has been documented that brief repetitive periods of ischemia and reperfusion (ischemic preconditioning, IP) enhances the recovery of post-ischemic contractile function and reduces infarct size after a longer period of ischemia. Many mechanisms have been proposed to explain this process. Recent studies have suggested that transient increase in the intracellular calcium may have triggered the activation of protein kinase C(PKC); however, there are still many controversies. Accordingly, the author performed the present study to test the hypothesis that preconditioning with high concentration of calcium before sustained subsequent ischemia(calcium preconditioning) mimics IP by PKC activation. Material and Method : The isolated hearts from the New Zealand White rabbits(1.5∼2.0 kg body weight) Method: The isolated hearts from the New Zealand White rabbits(1.5∼2.0 kg body weight) were perfused with Tyrode solution by Langendorff technique. After stabilization of baseline hemodynamics, the hearts were subjected to 45-minute global ischemia followed by a 120-minute reperfusion with IP(IP group, n=13) or without IP(ischemic control, n=10). IP was induced by single episode of 5-minute global ischemia and 10-minute reperfusion. In the Ca2+ preconditioned group, perfusate containing 10(n=10) or 20 mM(n=11) CaCl2 was perfused for 10 minutes after 5-minute ischemia followed by a 45-minute global ischemia and a 120-minute reperfusion. Baseline PKC was measured after 50-minute perfusion without any treatment(n=5). Left ventricular function including developed pressure(LVDP), dP/dt, heart rate, left ventricular end-diastolic pressure(LVEDP) and coronary flow(CF) was measured. Myo car ial cytosolic and membrane PKC activities were measured by 32P-${\gamma}$-ATP incorporation into PKC-specific pepetide. The infarct size was determined using the TTC (tetrazolium salt) staining and planimetry. Data were analyzed using one-way analysis of variance(ANOVA) variance(ANOVA) and Tukey's post-hoc test. Result: IP increased the functional recovery including LVDP, dP/dt and CF(p<0.05) and lowered the ascending range of LVEDP(p<0.05); it also reduced the infarct size from 38% to 20%(p<0.05). In both of the Ca2+ preconditioned group, functional recovery was not significantly different in comparison with the ischemic control, however, the infarct size was reduced to 19∼23%(p<0.05). In comparison with the baseline(7.31 0.31 nmol/g tissue), the activities of the cytosolic PKC tended to decrease in both the IP and Ca2+ preconditioned groups, particularly in the 10 mM Ca2+ preconditioned group(4.19 0.39 nmol/g tissue, p<0.01); the activity of membrane PKC was significantly increased in both IP and 10 mM Ca2+ preconditioned group (p<0.05; 1.84 0.21, 4.00 0.14, and 4.02 0.70 nmol/g tissue in the baseline, IP, and 10 mM Ca2+ preconditioned group, respectively). However, the activity of both PKC fractions were not significantly different between the baseline and the ischemic control. Conclusion: These results indicate that in isolated Langendorff-perfused rabbit heart model, calcium preconditioning with high concentration of calcium does not improve post-ischemic functional recovery. However, it does have an effect of limiting(reducing) the infart size by ischemic preconditioning, and this cardioprotective effect, at least in part, may have resulted from the activation of PKC by calcium which acts as a messenger(or trigger) to activate membrane PKC.

  • PDF

The design of C-GIS and the analysis of its Performance test results (C-GIS의 설계 및 성능평가 결과분석)

  • Shin, Y.J.;Kim, M.H.;Ryu, H.K.;Lee, Y.H.;Kim, C.H.;Kim, J.K.;Kim, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.551-553
    • /
    • 2002
  • The cubicle type GIS rated at 25.8kV has been designed and manufactured by Jinkwang E&C eacently with their own technologies and KERI's assistances. The C-GIS has been tested to check the design capability for reference before conducting the type test. The operating characteristics test, short time withstand current and peak withstand current test, basic short circuit test duty T60 for preconditioning test, cable charging current switching test, capacitor bank current switching test, basic short circuit test duty T100s and T100a, single phase earth fault test, double earth fault test has been conducted. The test results show that the design and the manufacturing of the C-GIS has an enough capability to pass through the type test except the occurrence of 2 NSDDs in the cable charging current switching test and the instability of opening time at the minimum operating voltage. The problems shown in the tests will be improved soon and the successful pass will be expected in the following type test.

  • PDF