• 제목/요약/키워드: precision validation

검색결과 563건 처리시간 0.024초

피로수명해석에 의한 지게차용 후차축 주물빔 설계 (Steeraxle Casting Beam Design of Forklift Truck by Fatigue Life Analysis)

  • 박진홍;구재민;이오영;석창성
    • 한국정밀공학회지
    • /
    • 제28권11호
    • /
    • pp.1309-1315
    • /
    • 2011
  • The design process for obtaining the reliable steeraxle casting beam of fork lift truck is studied in this paper, as the casting beam is major component of steeraxle which has a steering function at driving. In this study, the driving mode and damage pattern of casting beam which could be occurred from the customer site were analyzed and it established the design process to predict the fatigue life by FEA(Finite Element Analysis) so that the reliability of steeraxle casting beam could be verified at DVT(Design Validation Test) mode. This paper provides guidance on the process of designing the reliable steeraxle casting beam at the initial design stage and also, provides guidance on the process of solving the problem when the failure is occurred in the field.

생약복합제 GCSB-5의 품질 표준화를 위한 오가피 및 우슬의 함량 분석 (Quantitative Analysis of Acanthopanacis Cortex and Achyranthis Radix for Standardization of GCSB-5 Preparation)

  • 이은희;차배천
    • 생약학회지
    • /
    • 제39권4호
    • /
    • pp.316-323
    • /
    • 2008
  • In this study, we have investigated the HPLC analysis methods and quantitative analysis of standard compounds for quality standardization of a medicinal crude drug GCSB-5, a herbal formulation consisting of 6 medicinal plants (Acanthopanacis Cortex, Achyranthis Radix, Ledebouriellae Radix, Cibotii Rhizoma, Glycine Semen, Eucommiae Cortex) which are used in traditional medicine to treat various bone disorders. HPLC analysis methods of acanthoside D(Acanthopanacis Cortex), 20-hydroxyecdysone(Achyranthis Radix) which were known standard compounds among 6 medicinal plants were developed on crude material and product. And validation of HPLC analysis methods were conformed for verification of HPLC methods by check to specificity, linearity, intra-day precision, inter-day precision and accuracy following ICH guideline. Content of acanthoside D and 20-hydroxyecdysone on raw material of GCSB-5 were decided at 0.577-0.578 mg/g and 0.311-0.312 mg/g. And we confirmed that content of acanthoside D and 20-hydroxyecdysone on GCSB-5 preparation were 0.302-0.303 mg/capsule and 0.113-0.115 mg/capsule.

HPLC에 의한 Domoic acid 분석법 검정 (Validation of the Analysis of Domoic Acid using High Performance Liquid Chromatography)

  • 목종수;이가정;송기철;김지회
    • 한국수산과학회지
    • /
    • 제43권4호
    • /
    • pp.293-297
    • /
    • 2010
  • To prevent amnesic shellfish poisoning (ASP) resulting from the consumption of shellfish contaminated with domoic acid, the quantitative analysis of domoic acid is very important. We validated a high performance liquid chromatography (HPLC) method for accurate and precise quantification of domoic acid. A clear peak and the isolation of domoic acid resulted on injecting a 50% methanol extract of CRM-ASP-Mus-c mussel reference material using HPLC. The limit of detection of domoic acid under the established HPLC conditions was $0.10\;{\mu}g/g$, and the limit of quantification of the toxin under the same conditions was $0.25\;{\mu}g/g$. The intra-accuracy and precision for domoic acid in CRM-ASP-Mus-c were 90.7-95.7% and 0.28-22.25%, respectively. The inter-accuracy and precision for domoic acid were 89.1-97.1% and 1.7-4.1%, respectively. The mean recovery of domoic acid in methanol extracts from ten species of marine invertebrates was 88.6-1105.1%.

생약복합제 GCSB-5의 품질 표준화를 위한 흑두 및 두충의 함량 분석 (Quantitative Analysis of Glycine Semen Nigra and Eucommiae Cortex for Standardization of GCSB-5 Preparation)

  • 이은희;차배천
    • 생약학회지
    • /
    • 제40권1호
    • /
    • pp.18-24
    • /
    • 2009
  • GCSB-5 preparation is a purified extract from a mixture six herbal medicines (Acanthopanacis Cortex, Achyranthis Radix, Saposhnikoviae Radix, Cibotii Rhizoma, Glycine Semen Nigra, Eucommiae Cortex) that have been widely used in traditional medicine to treat various bone disorders. This study was carried out to obtain the HPLC analysis method that can be used to establish quantitative analysis of Glycine Semen Nigra and Eucommiae Cortex for standardization of GCSB-5 preparation. HPLC analysis methods for the simultaneous determination of genistin (Glycine Semen Nigra) and geniposide (Eucommiae Cortex) were established for the quality control of herbal medicinal raw material and preparation. And validation of HPLC analysis methods were conformed for verification of HPLC methods by check to specificity, linearity, intra-day precision, inter-day precision and accuracy following ICH guideline. As the result of quantitative analysis, the contents of genistin and geniposide in the raw material of GCSB-5 preparation were 0.0426-0.0427 mg/g and 0.431-0.432 mg/g. And GCSB-5 preparation contained genistin of 0.0202-0.0203 mg/capsule and geniposide of 0.211-0.212 mg/capsule, respectively.

LC/MS/MS를 이용한 원숭이 혈액에서의 Doxifluridine과 대사체 5-FU 동시분석법 개발 및 Validation (Quantitative Determination of Doxifluridine and 5-FU in Monkey Serum Using LC/MS/MS)

  • 우영아;김기환;김원;이종화;정은주;김진호;박귀례;김충용
    • 약학회지
    • /
    • 제51권3호
    • /
    • pp.174-178
    • /
    • 2007
  • A reverse-phase high performance liquid chromatography method with electrospray ionization and detection by mass spectrometry is described for the simultaneous determination of doxifluridine and its active metabolite 5-flu-orouracil (5-FU) in monkey serum. The method has greater sensitivity and simpler process than previous published methods with good accuracy and precision. A proper liquid/liquid extraction was used to extract simultaneously doxifluridine and 5-FU which has considerable difference in the polarity. Extracts were analyzed using LC/MS/MS providing a short analysis time within 5 min. The lower limit of quantification was validated at 10.0 ng/ml of serum for both doxifluridine and 5-FU. Accuracy and precision of quality control (QC) samples for both analytes met FDA Guidance criteria of ±15% for average QC accuracy with coefficients of variation less than 15%. The method will be applicable for preclinical studies and bioequivalence studies.

다양한 평가 지표와 최적화 기법을 통한 오염부하 산정 회귀 모형 평가 (Evaluation of Regression Models with various Criteria and Optimization Methods for Pollutant Load Estimations)

  • 김종건;임경재;박윤식
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.448-448
    • /
    • 2018
  • In this study, the regression models (Load ESTimator and eight-parameter model) were evaluated to estimate instantaneous pollutant loads under various criteria and optimization methods. As shown in the results, LOADEST commonly used in interpolating pollutant loads could not necessarily provide the best results with the automatic selected regression model. It is inferred that the various regression models in LOADEST need to be considered to find the best solution based on the characteristics of watersheds applied. The recently developed eight-parameter model integrated with Genetic Algorithm (GA) and Gradient Descent Method (GDM) were also compared with LOADEST indicating that the eight-parameter model performed better than LOADEST, but it showed different behaviors in calibration and validation. The eight-parameter model with GDM could reproduce the nitrogen loads properly outside of calibration period (validation). Furthermore, the accuracy and precision of model estimations were evaluated using various criteria (e.g., $R^2$ and gradient and constant of linear regression line). The results showed higher precisions with the $R^2$ values closed to 1.0 in LOADEST and better accuracy with the constants (in linear regression line) closed to 0.0 in the eight-parameter model with GDM. In hence, based on these finding we recommend that users need to evaluate the regression models under various criteria and calibration methods to provide the more accurate and precise results for pollutant load estimations.

  • PDF

Validation and measurement uncertainty of HPLC-UV method for quercetin quantification in various foods

  • Seo, Eunbin;Lim, Suji;Yun, Choong-In;Shin, Jae-Wook;Kim, Young-Jun
    • 한국식품과학회지
    • /
    • 제53권6호
    • /
    • pp.682-687
    • /
    • 2021
  • The purpose of this study was to validate a high-performance liquid chromatography (HPLC) method for the quantitative analysis of quercetin in various foods. The method was based on HPLC-UV (360 nm). The method was validated using candy, beverage, and sausage which were tested for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. Matrix-matched calibration was also applied. The calibration curves (0.5-50 mg/L) showed good linearity (r2≥0.9998). LOD and LOQ ranged from 0.15 to 0.31 mg/kg and from 0.44 to 0.93 mg/kg, respectively. The average accuracy and precision at 0.5, 2.5, and 10 mg/kg ranged from 84.3 to 102.0% and 0.7 to 3.0 relative standard deviation (RSD%), respectively. This study confirmed the applicability of the proposed method by applying it to commercial products, such as teas and beverages. Thus, the proposed analytical method is suitable for quantifying quercetin in various foods.

Validation of an analytical method for cyanide determination in blood, urine, lung, and skin tissues of rats using gas chromatography mass spectrometry (GC-MS)

  • Shin, Min-Chul;Kwon, Young Sang;Kim, Jong-Hwan;Hwang, Kyunghwa;Seo, Jong-Su
    • 분석과학
    • /
    • 제32권3호
    • /
    • pp.88-95
    • /
    • 2019
  • This study was conducted to establish the analytical method for the determination of cyanide in blood, urine, lung and skin tissues in rats. In order to detect or quantify the sodium cyanide in above biological matrixes, it was derivatized to Pentafluorobenzyl cyanide (PFB-CN) using pentafluorobenzyl bromide (PFB-Br) and then reaction substance was analyzed using gas chromatography mass spectrometer (GC/MS)-SIM (selected ion monitoring) mode. The analytical method for cyanide determination was validated with respect to parameters such as selectivity, system suitability, linearity, accuracy and precision. No interference peak was observed for the determination of cyanide in blank samples, zero samples and lower limit of quantification (LLOQ) samples. The lowest limit detection (LOD) for cyanide was $10{\mu}M$. The linear dynamic range was from 10 to $200{\mu}M$ for cyanide with correlation coefficients higher than 0.99. For quality control samples at four different concentrations including LLOQ that were analyzed in quintuplicate, on six separate occasions, the accuracy and precision range from -14.1 % to 14.5% and 2.7 % to 18.3 %, respectively. The GC/MS-based method of analysis established in this study could be applied to the toxicokinetic study of cyanide on biological matrix substrates such as blood, urine, lung and skin tissues.

Analytical Method Validation of (-)Epicatechin gallate in Penthorum chinense Pursh Extract using HPLC

  • Kwon, Jin Gwan;Jung, Yeon Woo;Seo, Changon;Hong, Seong Su;Lee, Ji Eun;Shin, Hyun Tak;Jung, Su Young;Choi, Chun Whan;Kim, Jin Kyu
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2019년도 춘계학술대회
    • /
    • pp.100-100
    • /
    • 2019
  • This study attempted to establish a High Performance Liquid Chromatography (HPLC) analysis method for the determination of (-)-epicatechin gallate as a part of the quality control for the development of functional cosmetic materials from Penthorum chinense Pursh extracts. HPLC was performed on a Unison US-C18 column ($4.6{\times}250mm$, $5{\mu}m$) with a gradient elution of 0.05% (v/v) trifluoroacetic acid (TFA) and methyl alcohol at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analyte was detected at 280 nm. The HPLC method was performed in accordance with the International Conference on Harmonization (ICH) guideline (version 4, 2005) of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation were 0.11 and 0.33 mg/mL, respectively. Calibration curves showed good linearity (r2 > 0.9999), and the precision of analysis was satisfied (less than 0.6%). Recoveries of quantified compounds ranged from 99.51 to 101.92%. This result indicates that the established HPLC method is very useful for the determination of marker compound in P. chinense Pursh extracts.

  • PDF

종자류 식품에 함유된 5종 리그난의 동시 분석법 개발 (Development of Simultaneous Analytical Method for Five Lignans in Edible Seeds)

  • 김윤정;편지예;백인환;김영화
    • 한국식품영양학회지
    • /
    • 제35권6호
    • /
    • pp.543-551
    • /
    • 2022
  • There has been increased interest in lignans due to their potential effect in reducing the risk of developing several diseases. To evaluate lignan contents, sensitive and accurate methods should be developed for their quantification in food. The present study aimed to validate a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of 5 lignans: lariciresinol (Lar), matairesinol (Mat), pinoresinol (Pin), secoisolariciresinol (Seco), and syringaresinol (Syr). The validation included selectivity, linearity, recovery, accuracy, and precision. The method was proved to be specific, with a linear response (R2≥0.99). The limits of detection were 0.040~0.765 ㎍/100 g and the limits of quantification were 0.114~1.532 ㎍/100 g. Recoveries were 90.588~109.053% for black sesame powder. Relative standard deviations of repeatability and reproducibility were below 5%. Total lignan contents of roasted coffee bean, oat, and blacksoy bean were 105.702 ㎍/100 g, 78.965 ㎍/100 g, and 165.521 ㎍/100 g, respectively. These results showed that LC-MS/MS analysis would be effective in producing acceptable sensitivity, accuracy, and precision in five lignan analyses.