• Title/Summary/Keyword: precision safety inspection

Search Result 65, Processing Time 0.03 seconds

Cascade Network Based Bolt Inspection In High-Speed Train

  • Gu, Xiaodong;Ding, Ji
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.10
    • /
    • pp.3608-3626
    • /
    • 2021
  • The detection of bolts is an important task in high-speed train inspection systems, and it is frequently performed to ensure the safety of trains. The difficulty of the vision-based bolt inspection system lies in small sample defect detection, which makes the end-to-end network ineffective. In this paper, the problem is resolved in two stages, which includes the detection network and cascaded classification networks. For small bolt detection, all bolts including defective bolts and normal bolts are put together for conducting annotation training, a new loss function and a new boundingbox selection based on the smallest axis-aligned convex set are proposed. These allow YOLOv3 network to obtain the accurate position and bounding box of the various bolts. The average precision has been greatly improved on PASCAL VOC, MS COCO and actual data set. After that, the Siamese network is employed for estimating the status of the bolts. Using the convolutional Siamese network, we are able to get strong results on few-shot classification. Extensive experiments and comparisons on actual data set show that the system outperforms state-of-the-art algorithms in bolt inspection.

Method Development for Determination of Chlorogenic Acid and Arbutin Contents in Fruits by UHPLC-MS/MS (UHPLC-MS/MS를 이용한 과일류 중 클로로젠산 및 알부틴 동시분석법 개발)

  • Choi, Young-Ju;Jeon, Jong-Sup;Kim, Woon-Ho;Jung, You-Jung;Ryu, Ji-Eun;Choi, Jong-Chul;Chae, Kyung-Suk;Lee, Jin-Hee;Do, Young-Sook;Park, Young-Bae;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.5
    • /
    • pp.413-420
    • /
    • 2019
  • In this study, a sample preparation method and a simultaneous determination method by ultra-high performance liquid chromatography coupled with tandem mass spectrometry for 9 isomers of chlorogenic acid and arbutin in fruits were developed. The samples were extracted using 90% methanol (pH 3.0), with the solutions being shaken and then sonicated for 10 min each. After centrifugation at 4,000 rpm for 10 min, the extraction was concentrated under a vacuum at $40^{\circ}C$ using a vacuum evaporator. The residue was dissolved in 5 mL of 5% methanol and filtered through a $0.45{\mu}m$ membrane before UHPLC-MS/MS analysis. The separations were performed on a C18 column with gradient elution of water (containing 0.1% formic acid) and methanol (containing 0.1% formic acid). The specificity, linearity, limit of detection, limit of quantification, accuracy, and precision of the proposed methods were also evaluated.

Application of Probabilistic Fracture Mechanics Technique Using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 확률론적 파괴역학 수법의 적용성 검토)

  • Lee, Joon-Seong;Kwak, Sang-Log;Kim, Young-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.10
    • /
    • pp.154-160
    • /
    • 2001
  • For major structural components periodic inspections and integrity assessments are needed for the safety. However, many flaws are undetectable because sampling inspection is carried out during in-service inspection. Probabilistic integrity assessment is applied to take into consideration of uncertainty and variance of input parameters arise due to material properties and undetectable cracks. This paper describes a Probabilistic Fracture Mechanics(PFM) analysis based on the Monte Carlo(MC) algorithms. Taking a number of sampling data of probabilistic variables such as fracture toughness value, crack depth and aspect ratio of an initial surface crack, a MC simulation of failure judgement of samples is performed. for the verification of this analysis, a comparison study of the PFM analysis using a commercial code, mathematical method is carried out and a good agreement was observed between those results.

  • PDF

Evaluation on Degradation of Heat exchanger (열교환기의 경년열화 평가)

  • Oh H.S.;Jung H.Y.;Park S.P.;Yang S.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1672-1677
    • /
    • 2005
  • The Heat exchanger to be used in the place of business that is presented an utility period comes to be long and the problem of the length of life shares by the manufacture course and using environment factor. Consequentl, it is came to the front problem of inspection, repair, exchange, the utility stopping, safety and confidence. As a result the possibility which the large safety accident can happen comes to be high. It leads mostly to the large accedent when the explosion accident happens. to keep this, The system which the regular period passes to disuse the structure is prepared but The phenomenon which Time and the strength characteristic of the material change, namely Deradation. but It can't be a preventable solution by accident to the damage. Consequentl, This research can take important role to prevent an every kind accident for domestic pressure vessel by evaluating the mechnical characteristic change of meterial, the structure safety and residual life etc.

  • PDF

Suggestion for the Maintenance Program of the Sea Dike Using Geophysical Methods (지구물리학적 방법을 이용한 방조제 유지·관리 체계 제안)

  • Yong, Hwan-Ho;Cho, In-Ky;Song, Sung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.4
    • /
    • pp.275-283
    • /
    • 2013
  • The sea dike is the most important facility of reclamation projects, and plays an important role in securing freshwater in the reservoir. Systematic research on practical approaches and data analysis techniques are lacking even though some geophysical methods such as electrical resistivity and self-potential surveys are included within the inspection processes. Hence, geophysical methods were considered for improvement of precision safety diagnosis methods after problems in the maintenance system have been identified, such as safety checks and precision safety diagnoses. In addition, geophysical methods customized according to variations in ambient environmental limiting factors such as pore pressure changes by tidal fluctuation, compaction characteristics of the fill materials, and the surface condition of the embankment were suggested.

The Corelation Analysis between Condition Evaluation Factors and Defect Index on the Concrete Retaining Wall (콘크리트 옹벽에 대한 상태평가 항목과 결함지수와의 상관관계 분석)

  • Seong, Joo Hyun;Byun, Yoseph;Lee, Dong Yul;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.52-58
    • /
    • 2015
  • Although lots of safety inspection and precision safety diagnosis have been conducted on concrete retaining wall, there is no comprehensive analysis on the basis of the accumulated data associated with the statistic. Especially, the concentrated management is necessary on the evaluation items that cause critical damages for the efficient performance. In this regard, this study conducted a correlation analysis between the 18 condition evaluation items and defect index for the concrete retaining wall as well as how each item affects the final defect index as much as in the manual. As a result, correlation coefficient between sliding and overturning was 0.601, which means that they have a strong correlation, and the most influential item on defect index is the condition of drainage that scored the 0.750 correlation coefficient. In addition, as a result of regression analysis, the condition of drainage with the 0.683 correlation coefficient has a strong correlation with the defect index. If the condition evaluation items are integrated or readjusted based on the results of the statistical analysis in this study, the more efficient and accurate maintenance will be possible.

The Evaluation of Non-Destructive Formulas on Compressive Strength Using the Reliability Based on Probability (확률 기반의 신뢰도를 이용한 비파괴 압축강도 추정식 평가)

  • Park, Jin-Woo;Choo, Jin-Ho;Park, Gwang-Rim;Hwang, In-Baek;Shin, Yong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.25-34
    • /
    • 2015
  • Proposed equation is used many time in calculation of concrete compressive strength using the non-destructive testing at precision safety diagnosis. Most of proposed equation is suggested in abroad and have an error to estimate concrete compressive strength in the domestic. Therefor, proposed equation is low reliability to estimate concrete compressive and it has a significant effect in reliability of precision safety diagnosis. Nevertheless, It is possible to increase the reliability through a number of experiments from this problem that occurs in some localized part. This paper is proposed assessment formula of reliability related core compressive strength to increase the reliability. It is verified that reliability of proposed assessment formula is useful by probabilistic techniques. It is compared with each graphs of concrete compressive strength of proposed equation. It has been found that the present methods are very efficient.

The Development and Introduction of External Corrosion Direct Assessment Measures for Urban Gas Pipelines (외면부식 직접평가법 개발 및 국내 도입 연구)

  • Ryou, Young-Don;Lee, Jin-Han;Yoon, Yung-Ki;Lim, Ho-Seok
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.12-19
    • /
    • 2014
  • To minimize the risk of corrosion on buried pipeline and to maximize the efficiency of cathodic protection, various indirect inspection techniques have been used for decades. In the United States, 49 CFR has regulated the external corrosion direct assessment for buried pipelines. In Korea, there is no provision for external corrosion direct assessment but there is only, according to the KGS Code, provision that if the survey of the defects of buried pipeline and the leakage test for the pipe were conducted, it is deemed to leakage inspection. We, therefore, have suggested external corrosion direct assessment method appropriate to domestic status through the survey of the regulations and standards of UK and the USA and the investigation of domestic situation on coating damage detection method. The proposed external corrosion direct evaluation method was used as the basis when introducing the precision safety diagnosis regulation for the medium-pressure pipe in Korea.

Analysis of Hexaconazole in Agricultural Products using Multi Class Pesticide Multiresidue Method (다종 농약 다성분 분석법을 이용한 농산물 중 hexaconzole 분석)

  • Choi, Su Jeong;Hwang, In Sook;Cho, Tae Hee;Lee, Jae In;Lee, In Sook;Yook, Dong Hyun;Park, Won Hee;Kim, Moo Sang;Kim, Gun Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.4
    • /
    • pp.366-371
    • /
    • 2015
  • This work was conducted to apply the multi class pesticide multiresidue method for determining the use of hexaconazole in the agricultural products using GC-NPD. The multi class pesticide multiresidue method results were validated for the assay of hexaconazole by using linearity, accuracy, precision, limit of detection and quantitation. The linearity in the concentration ranged from 0.025 to 5.0 mg/L ($R^2$ > 0.999). Lettuce recoveries ranged from 89.42% to 94.15% with relative standard deviations below 7.78%, for spiking levels from 0.04 to 4.0 mg/kg. The limit of detection was 0.04 mg/kg, and the limit of quantitation was 0.11 mg/kg. The intra- and inter-day precisions were 2.42~3.49% and 4.90~7.78%, respectively. We suggested that the multi class pesticide multiresidue method for determining hexaconazole was highly accurate and reproducible, and it will be used as a routine analysis in agricultural products.

Device Design for Inspection Curved Pipes using the Mobile Robot (이동로봇을 이용한 곡관(Curved Pipes) 검사용 디바이스 설계)

  • 조현영;최창환;최용제;김승호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1458-1462
    • /
    • 2003
  • High temperature and high pressure heavy water flows through the pipes in atomic power plants. The curved parts of pipes are critical parts in that they change the direction of steam flow, and these parts are especially affected by severe wear. Therefore, most pipes in atomic power plants are tested by non-destructive examination by workers who use ultrasonic sensors to measure the wall thickness of pipes. But not only are these pipes located in a very dangerous environment, but the space is also very limited. For the safety of workers, it is necessary to design a device that uses a mobile robot that can inspect curved pipes. This paper presents the design and construction of a small device that can generate the necessary contact forces between ultrasonic sensors and pipe walls in a limited space. And a mobile robot is used in place ortho worker for successful non-destructive examination.

  • PDF