• Title/Summary/Keyword: precise time

Search Result 1,922, Processing Time 0.025 seconds

Simple Determination Method on Optimal Dosage of Polymer for Papermaking Wastewater Treatment (제지폐수처리의 고분자 응집제 주입량 간이 결정법)

  • Cho, Jun-Hyung;Kang, Mee-Ran;Jin, Hai-Lan
    • Journal of Forest and Environmental Science
    • /
    • v.30 no.1
    • /
    • pp.85-90
    • /
    • 2014
  • Dewaterability, one of the important properties of wastewater sludge, was investigated using a simple capillary suction time (CST) measurement method. CST and SRF have a very close co-relation. It was convinced that CST method was quite effective, and compensating the time-consuming SRF of conventional drainage measuring method. It turned out that one could use the results of CST to find optimum flocculants ratio to improve drainage in wastewater treatment for the tissue paper production at a mill. Since the optimum ratio of flocculants could be determined with the value of CST and COD removal efficiency could be improved with precise ratio of flocculants. Thus, using CST for determining the optimum ratio of flocculants could be economical by reducing the amount of flocculants. Dewaterability might be measured within several seconds using the values of CST in a precise way. The dewaterability could also be useful in investigating the optimum ratio of flocculants.

Analysis of Tropospheric Zenith Path Delay of GPS Code Based Precise Time Comparison Technique (GPS 코드 기반 정밀시각비교기법의 대류층 천정지연모델 분석)

  • Yu, Dong-Hui;Yang, Sung-Hoon;Do, Jae-Chul;Lee, Chang-Bok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.61-69
    • /
    • 2012
  • This paper shows results of the precise time comparison technique based on GPS code transfer in order to determine the UTC(Universal Time Coordinated) and generate TAI(International Atomic Time). CGGTTS(CCTF Group on GNSS Time Transfer Standards) which is generated by GPS timing receivers is used as the international standard format. For geodetic receivers which provide RINEX formats as GPS time transfer results, ROB(Royal Observatory of Belgium) developed a conversion program, r2cggtts, and have distributed the program to timing laboratories participating in TAI link all over the world. Timing laboratories generate the time comparison results of GPS code transfer by the program and send them to BIPM(Bureau International des Poids et Mesures) periodically. In this paper, we introduce the delay features generated while GPS code is transferred and the calibration methods of them. Then, we introduce the tropospheric delay and analyze the results of Saastamoinen model and NATO(North Atlantic Treaty organization) model. Saastamoinen model is the representative tropospheric zenith path delay model and NATO model is applied to the legacy r2cggtts program.

Effect of Route of Preoperative Biopsy on Endoscopic Submucosal Dissection for Patients with Early Gastric Cancer

  • Jiang, Hui;Tu, Hui-Ming;Qiao, Qiao;Xu, Ke-Bin;Li, Jie;Qi, Xiao-Wei;Ge, Xiao-Song
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8917-8921
    • /
    • 2014
  • Objective: To observe and compare the effects of multi-patch biopsy under conventional white light imaging endoscopy (C-WLI) and precise targeted biopsy under magnifying narrow-band imaging endoscopy (M-NBI) on the endoscopic submucosal dissection (ESD) of early gastric cancers and intraepithelial neoplasias. Methods: According to the way of selecting biopsy specimens, patients were divided into C-WLI and M-NBI groups, 20 cases. The ESD operations of the 2 groups were compared quantitively. Results: The mean frequency of biopsy in M-NBI group was ($1.00{\pm}0.00$), obviously lower than in the C-WLI group ($4.78{\pm}1.02$) (P<0.01).The average total number of selected biopsy specimens was also fewer ($1.45{\pm}0.12$ and $7.82{\pm}2.22$, respectively, P<0.01). There was no significant difference in the time of determining excision extension, marking time and the time of specimen excision of 2 groups during the ESD (P>0.05), whereas submucosal injection time, mucosal dissection time, stopping bleeding time, wound processing time in the M-NBI group were significantly shorter than in the C-WLI group (P<0.01). Conclusion: Precise targeted biopsy under M-NBI can obviously shorten the time of ESD operation, with small quantity of tissues but high pathological positive rate.

The Study for Improving Performance in IDGPS using IS-801 (IS-801을 이용한 IDGPS의 성능향상 방법 연구)

  • 현문필;김현수;지규인;김병수;김학렬
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.63-63
    • /
    • 2000
  • This paper is about the method to improve the IDGPS system using receiver which is not aligned to GPS time. Transmitted data between server and user is constructed in PDDM of IS-801 rule. Pseudorange is overflowed in case of using receiver unaligned GPS time. And satellite position is miscalculated because earth rotating effect is not corrected. To solve this problem, when Pseudorange measurement is over the maximum range, the Pseudorange measurement is reset. And after the rough user position and transmit time is calculated, the precise Pseudorange measurement is calculated.

  • PDF

Methodologies to Decide the Number of Samples and to Verify an Accuracy Rate of the Precise Guided Missiles for Test and Evaluation (정밀유도무기 시험평가 수량 결정 및 명중률 검증 방법론)

  • Lee, Moon-gul;Hwang, Seung-hoon;Baek, Seung-Ryoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.558-565
    • /
    • 2015
  • The current methods, such as Binomial Probability Distribution or T-test, to calculate the number of samples of Precise Guided Missiles(PGMs) for test and evaluation are statistically problematic to make reasonable decisions thus use the budget efficiently. Also, the method to verify an accuracy rate of the PGMs using these old methods seems to be lack of objectiveness. This paper presents an effective, efficient solution adapted from the clinical medicine testing method of healthcare industry research, which may overcome our problems. This method considers and addresses both manufacturers' and consumers' risk simultaneously. By taking into account the weapon system project characteristics which take a relatively longer time and require higher-level budget, this approach also suggests a reasonable and feasible method to determine the amount of samples of the PGMs and making a criterion to verify an accuracy rate of the missiles that are required to test. Thus, this method is expected to contribute to acquisition and operations of high-reliability PGMs by MND and its field-users.

A Study of the Opacity Correlation Factor between the Filtration Type and Light Extinction Type Diesel Smoke Meters (여지반사식과 광투과식 매연측정기의 매연도 상관계수에 관한 연구)

  • Kim, Young-Ju;Park, Kyoung-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.146-152
    • /
    • 2007
  • Recently, The air pollution problems become hot issues as the production of the diesel automotive increases. The ministry of environment has enforced a precise inspection law to decrease the vehicle emission. In this circumstances, the smoke measurement is somewhat complicated by the use of the different type smoke meters. Although the paper filtration type opacimeter has been used for measuring smoke widely but currently the light extinction type is being used for precise inspection law. These two type opacimeters are different in their measuring principles on each other. So, for the time being the regulation standards can be confused by these two type opacimeters. In this article, The correlation factor between these two type opacimeters is studied by using engine dynamometer and vehicle test. The result of the dynamometer test shows the light extinction type is more sensitive than the filtration type by 1.47 times. But the relation factor by the vehicle test achieved 1.37 value, which is lower than that of the dynamometer test. In the future study the more precise research is needed to estimate the relation factor on vehicle test.

The Precision Validation of the Precise Baseline Determination for Satellite Formation

  • Choi, Jong-Yeoun;Lee, Sang-Jeong
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.1
    • /
    • pp.63-70
    • /
    • 2011
  • The needs for satellite formation flying are gradually increasing to perform the advanced space missions in remote sensing and observation of the space or Earth. Formation flying in low Earth orbit can perform the scientific missions that cannot be realized with a single spacecraft. One of the various techniques of satellite formation flying is the determination of the precise baselines between the satellites within the formation, which has to be in company with the precision validation. In this paper, the baseline of Gravity Recovery and Climate Experiment (GRACE) A and B was determined with the real global positioning system (GPS) measurements of GRACE satellites. And baseline precision was validated with the batch and sequential processing methods using K/Ka-band ranging system (KBR) biased range measurements. Because the proposed sequential method validate the baseline precision, removing the KBR bias with the epoch difference instead of its estimation, the validating data (KBR biased range) are independent of the data validated (GPS-baseline) and this method can be applied to the real-time precision validation. The result of sequential precision validation was 1.5~3.0 mm which is similar to the batch precision validation.

Iterative coupling of precise integration FEM and TD-BEM for elastodynamic analysis

  • Lei, Weidong;Liu, Chun;Qin, Xiaofei;Chen, Rui
    • Structural Engineering and Mechanics
    • /
    • v.67 no.4
    • /
    • pp.317-326
    • /
    • 2018
  • The iterative decomposition coupling formulation of the precise integration finite element method (FEM) and the time domain boundary element method (TD-BEM) is presented for elstodynamic problems. In the formulation, the FEM node and the BEM node are not required to be coincident on the common interface between FEM and BEM sub-domains, therefore, the FEM and BEM are independently discretized. The force and displacement converting matrices are used to transfer data between FEM and BEM nodes on the common interface between the FEM and BEM sub-domains, to renew the nodal variables in the process of the iterations for the un-coincident FEM node and BEM node. The iterative coupling formulation for elastodynamics in current paper is of high modeling accuracy, due to the semi-analytical solution incorporated in the precise integration finite element method. The decomposition coupling formulation for elastodynamics is verified by examples of a cantilever bar under a Heaviside-type force and a harmonic load.

Design and Implementation for Motion Control System with Precise Driving Mechanism (정밀구동메커니즘 적용 모션제어시스템 설계 및 구현)

  • Lee, Sang-Kyung;Lee, Jun-Yeong;Choi, Yun-Seok;Park, Hong Bea
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.3
    • /
    • pp.129-136
    • /
    • 2013
  • In this paper, a motion control system based on 2-axis gimbal system is designed and implemented to drive a high speed and precision. The proposed system consists of the RS-422 interface, 2-axis gimbal platform, servo control unit integrated with a high speed DSP chip-set, servo amplifier unit, potentiometer sensor unit, and resolver sensor unit. The servo control unit using the high speed DSP firmware is designed to get a fast response without an overshoot with step input and a RMS error of low probability with ramp input. The servo amplifier unit using a voltage control is designed to resolve the zero-crossing distortion for precise motion. To verify the performance and stability of the implemented system, experiments are performed through a measurement of the time and frequency domain response in a laboratory environment by using a PXI(PCI eXtentions for Instrumentation).

Accuracy Analysis of Precise Point Positioning Using Predicted GPS Satellite Orbits (GPS 예측궤도력을 이용한 정밀단독측위 정확도 분석)

  • Ha, Ji-Hyun;Heo, Moon-Beom;Nam, Gi-Wook
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.752-759
    • /
    • 2012
  • In this paper, near-real-time positioning accuracies of precise point positioning technique were analyzed using IGS predicted orbits. As a result, we could get the mean errors of 1~1.6 cm, standard deviation of 1~1.3cm from one year of GPS data. This results were similar level to positioning accuracy using the IGS rapid orbits. Positioning errors of >10cm showed 44% of observed days of orbital anomalies. When the orbital anomalies of the predicted orbits were shown, maximum error was 1.7 km, and maximum of mean errors was 308 m. From this study, we conclude that check and consideration were necessary before using the IGS predicted orbits.