Design of Apnea Monitoring System by impedance technique (임피던스를 이용한 무호흡감시 시스템 설계)

  • Park, S.B.;Jeon, D.K.;Yoon, H.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.232-235
    • /
    • 1997
  • Apnea refers to episode of apnea (or not breathing) lasting more than 10 seconds that occur while sleeping. These episodes, whitch can occur hundreds of times per night, may transiently awaken resulting in fragmentation of sleep. Although the precise cause of Sudden Infant Death Syndrome(SIDS) are still unclear, there is evidence to suggest that hypoxaemia may be a contributory actor. Transcutaneous oxygen monitor can be used, but it is very difficult to use or baby stayed at home. In this reason, monitors whitch is easy or deal with are reqiured. In 1972, Steinschieder reported that two of the five infants noted to have apnea lasting or more than 20 seconds later died of SIDS episode, he also suggested that home monitoring or neonates should be used or managing apnea at home. Transthoracic electrical impedance technique is used or acquiring respiration waveform and detecting episode of apnea state. Transthoracic electrical impedance measurements have been made from the human trunk over the frequency range 9.6KHz to 614KHz. We conclude that application of impedance technique or detecting apnea state is proper or neonates.

  • PDF

Design and Implementation of Receiver Network Elements for Real-Time Precise GPS/GNSS (실시간 정밀 GPS/GNSS를 위한 위성항법 수신기 망 구성 요소 설계 및 구현)

  • Kim, Hee-Sung;Lee, Hyung-Keun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.2
    • /
    • pp.126-133
    • /
    • 2010
  • Due to the deployment of various wireless networks originating from CDMA, GSM, and WLAN, it became very convenient to exchange information from one place to another. As compared with the traditional environments for one-way information distribution based on fixed radio frequency bands, the convenient wireless network environments will bring about many changes in positioning technologies based on global navigation satellites. Among the many changes to come, the reconfigurable receiver network is one of the most attractive concepts since it can be tailored to a specific application area among networked robots, formation flying, bridge monitoring, and traffic monitoring. As an initial study to develop a reconfigurable receiver network, this paper deals with the design and implementation of the key elements of the reconfigurable receiver netowork; server, broadcaster, and client. In the designed receiver network, a sever receives and decodes measurements from a reference receiver installed at a known location, a broadcaster processes and transfers the messages from servers to clients and manages connections with servers and clients, a client receives the messages from the broadcaster and performs differential positioning. A real-time experiment result is demonstrated to validate the functionalities of each network element.

Early-stage Diagnosis of Bladder Carcinoma by a Clinical Pharmacist's Effective Anti-coagulation Service in a Patient with Anticoagulation Therapy: a Clinical Case Report (항응고제 투여 환자에서 약사의 효과적인 ACS를 통한 방광암 조기발견 사례)

  • An, Sung-Shim;Bang, Joon-Seok;La, Hyen-Oh
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.1
    • /
    • pp.85-87
    • /
    • 2010
  • Recently, the prevalence of bladder cancer is increasing in the Korean society. As the risk factors of bladder carcinoma are variable, the early-stage diagnosis is regarded the best preventive practice. Hematuria is a specific sign of the malignancy as well as a kind of various medication-related adverse reactions. Some anti-coagulation therapy can cause bleedings including hematuria to the patients with cardiovascular diseases such as paroxysmal atrial fibrillation (PAF). Therefore, to the clinical pharmacists working in the anti-coagulation services (ACS), a closer monitoring of patients can give an opportunity to find certain ailments unexpectedly. In this case, a patient with PAF had episodes of sporadic hematuria in the course of warfarin therapy even though with its low levels of INR. An ACS pharmacist found a discrepancy between the bleeding symptoms and INR values, and recommended properly the patient to refer urologist. Fortunately, an early-stage of bladder carcinoma was found then followed by an excision performed to the lesion. Therefore, alert-minded and precise monitoring done by ACS pharmacist could optimize the therapeutic outcomes as well as increase the quality of life of the patient.

Development of ultra-high frequency (UHF) ultra-wide bandwidth signal processing unit for UHF partial-discharge monitoring system for gas-insulated switchgears (가스절연개폐장치용 부분방전 감시 시스템을 위한 초광대역 극초단파 신호처리장치 개발)

  • Choi, Jae-Ok;Kim, Young-No;Lee, Young-Sang;Kang, Chang-Won;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.128-131
    • /
    • 2004
  • An ultra wide band ultra-high frequency (UHF) signal processing module was designed for on-line UHF partial discharge (PD) monitoring systems for gas-insulated switchgears (GIS). Major advantage of the unit is an improved PD detection sensitivity through minimizing the effect of surrounding interference signals. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PD signals as low as 1 pC. Precise detection of PD occurred in the GIS, due to internal defects, is possible by using the signal processing unit.

  • PDF

Advances in Rapid Detection Methods for Foodborne Pathogens

  • Zhao, Xihong;Lin, Chii-Wann;Wang, Jun;Oh, Deog Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.3
    • /
    • pp.297-312
    • /
    • 2014
  • Food safety is increasingly becoming an important public health issue, as foodborne diseases present a widespread and growing public health problem in both developed and developing countries. The rapid and precise monitoring and detection of foodborne pathogens are some of the most effective ways to control and prevent human foodborne infections. Traditional microbiological detection and identification methods for foodborne pathogens are well known to be time consuming and laborious as they are increasingly being perceived as insufficient to meet the demands of rapid food testing. Recently, various kinds of rapid detection, identification, and monitoring methods have been developed for foodborne pathogens, including nucleic-acid-based methods, immunological methods, and biosensor-based methods, etc. This article reviews the principles, characteristics, and applications of recent rapid detection methods for foodborne pathogens.

Antiepileptic Drugs in Children : Current Concept

  • Lee, Jeehun
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.3
    • /
    • pp.296-301
    • /
    • 2019
  • An epileptic seizure is defined as the transient occurrence of signs and/or symptoms due to abnormally excessive or synchronous neuronal activity in the brain. The type of seizure is defined by the mode of onset and termination, clinical manifestation, and by the abnormal enhanced synchrony. If seizures recur, that state is defined as epilepsy. Antiepileptic drugs (AEDs) are the mainstay of treatment. Knowledge about initiating and maintaining adequate AEDs is beneficial for the clinician who treats children with epilepsy. This article will delineate the general principles for selecting, introducing, and discontinuing AEDs and outline guidelines for monitoring adverse effects. In general, AED therapy following a first unprovoked seizure in children is not recommended. However, treatment should be considered after a second seizure. In children and adolescents, if they are seizure-free for at least 2 years, attempts to withdraw medication/s should be made, taking into account the risks vs. benefits for the individual patient. The decision on when and what AED to use should be tailored according to the patient. For optimal treatment, the selection of adequate AEDs can be achieved by considering the precise definition of the patient's seizure and epilepsy syndrome. Continuous monitoring of both therapeutic and adverse effects is critical for successful treatment with AEDs.

Dense Thermal 3D Point Cloud Generation of Building Envelope by Drone-based Photogrammetry

  • Jo, Hyeon Jeong;Jang, Yeong Jae;Lee, Jae Wang;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.2
    • /
    • pp.73-79
    • /
    • 2021
  • Recently there are growing interests on the energy conservation and emission reduction. In the fields of architecture and civil engineering, the energy monitoring of structures is required to response the energy issues. In perspective of thermal monitoring, thermal images gains popularity for their rich visual information. With the rapid development of the drone platform, aerial thermal images acquired using drone can be used to monitor not only a part of structure, but wider coverage. In addition, the stereo photogrammetric process is expected to generate 3D point cloud with thermal information. However thermal images show very poor in resolution with narrow field of view that limit the use of drone-based thermal photogrammety. In the study, we aimed to generate 3D thermal point cloud using visible and thermal images. The visible images show high spatial resolution being able to generate precise and dense point clouds. Then we extract thermal information from thermal images to assign them onto the point clouds by precisely establishing photogrammetric collinearity between the point clouds and thermal images. From the experiment, we successfully generate dense 3D thermal point cloud showing 3D thermal distribution over the building structure.

Imperceptible On-Skin Sensor Devices for Musculoskeletal Monitoring and Rehabilitation (상시 근골격 모니터링과 재활을 위한 온스킨 센서 디바이스 기술)

  • Park, C.W.;Koo, J.B.;Jin, H.;Kim, Y.;Lim, C.;Hong, C.H.;Kim, H.J.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.2
    • /
    • pp.30-41
    • /
    • 2022
  • As the society is superaging, the number of patients with movement disabilities due to musculoskeletal or nervous system illness is rapidly increasing. To improve public health and reduce medical expenses, it is essential to develop rehabilitation systems that allow patients to resume their daily-life activities. However, the existing musculoskeletal illness diagnosis and rehabilitation method is limited in terms of precision and efficiency because it is based on an empirical diagnosis and prescription without regard for individual characteristics. To overcome these limits, it is critical to design a novel concept of routine rehabilitation therapy device that is capable of inducing musculoskeletal balance by the precise analysis of musculoskeletal usage patterns via the motion and the muscle activity tracking of linked muscles. This study introduces the trend of on-skin sensor device technology for routine musculoskeletal monitoring and therapy. For on-skin rehabilitation systems, skin-adhesive and stretchable motion/posture, electromyography, pressure sensors, small-size and low-power wireless sensor interfaces, and user-friendly rehabilitation contents based on new algorithms are combined.

WIRELESS SENSOR NETWORK BASED BRIDGE MANAGEMENT SYSTEM FOR INFRASTRUCTURE ASSET MANAGEMENT

  • Jung-Yeol Kim;Myung-Jin Chae;Giu Lee;Jae-Woo Park;Moon-Young Cho
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1324-1327
    • /
    • 2009
  • Social infrastructure is the basis of public welfare and should be recognized and managed as important assets. Bridge is one of the most important infrastructures to be managed systematically because the impact of the failure is critical. It is essential to monitor the performance of bridges in order to manage them as an asset. But current analytical methods such as predictive modeling and structural analysis are very complicated and difficult to use in practice. To apply these methods, structural and material condition data collection should be performed in each element of bridge. But it is difficult to collect these detailed data in large numbers and various kinds of bridges. Therefore, it is necessary to collect data of major measurement items and predict the life of bridges roughly with advanced information technologies. When certain measurement items reach predefined limits in the monitoring bridges, precise performance measurement will be done by detailed site measurement. This paper describes the selection of major measurement items that can represent the tendency of bridge life and introduces automated bridge data collection test-bed using wireless sensor network technology. The following will be major parts of this paper: 1) Examining the features of conventional bridge management system and data collection method 2) Mileage concept as a bridge life indicator and measuring method of the indicator 3) Test-bed of automated and real-time based bridge life indicator monitoring system using wireless sensor network

  • PDF

A Derivation of Aerosol Optical Depth Estimates from Direct Normal Irradiance Measurements

  • Yun Gon Lee;Chang Ki Kim
    • New & Renewable Energy
    • /
    • v.20 no.1
    • /
    • pp.79-87
    • /
    • 2024
  • This study introduces a method for estimating Aerosol Optical Depth (AOD) using Broadband Aerosol Optical Depth (BAOD) derived from direct normal irradiance and meteorological factors observed between 2016 and 2017. Through correlation analyses between BAOD and atmospheric components such as Rayleigh scattering, water vapor, and tropospheric nitrogen dioxide, significant relationships were identified, enabling accurate AOD estimation. The methodology demonstrated high correlation coefficients and low Root Mean Square Errors (RMSE) compared to actual AOD500 measurements, indicating that the attenuation effects of water vapor and the direct impact of tropospheric nitrogen dioxide concentration are crucial for precise aerosol optical depth estimation. The application of BAOD for estimating AOD500 across various time scales-hourly, daily, and monthly-showed the approach's robustness in understanding aerosol distributions and their optical properties, with a high coefficient of determination (0.96) for monthly average AOD500 estimates. This study simplifies the aerosol monitoring process and enhances the accuracy and reliability of AOD estimations, offering valuable insights into aerosol research and its implications for climate modeling and air quality assessment. The findings underscore the viability of using BAOD as a surrogate for direct AOD500 measurements, presenting a promising avenue for more accessible and accurate aerosol monitoring practices, crucial for improving our understanding of aerosol dynamics and their environmental impacts.