• 제목/요약/키워드: precast large panel

검색결과 45건 처리시간 0.021초

프리캐스트 대헝판 구조물의 접합부에 관한 탄소성해석 (Elasto-Plastic Analysis on Connections of Precast Large Panel Structures)

  • 권택진;박강근;권익노;조강표
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 봄 학술발표회논문집
    • /
    • pp.27-34
    • /
    • 1993
  • Precast large panel structures behave differently form frame and monolithic wall structures under external loads, because of the distinct planes of weakness in the horizontal and vertical joints between panels. These joints may slide and open during shaking, producing large localized changes in the bending and shear stiffness of individual walls. The structural behavior of large precast panel buildings depends on the relative strength and stiffness of the panels and joints. Special modeling are thus required for the analysis of precast panel connections. This study suggests a new analytical modeling and method to obtain the rational estimation of discontinuity and slip movements form the connections of precast large panel structures .

  • PDF

반복 횡하중을 받는 프리캐스트 대형 콘크리트 판구조의 이력특성에 관한 실험적 연구 (Hysteretic Behavior of Precast Concrete Large Panel Structures Subjected to Horizontal Cyclic Loading)

  • 서수연;이원호;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.253-260
    • /
    • 1999
  • Main objective of this study is to examine the hysteretic behaviors and to evaluate the capacity of precast concrete (PC) large panel structures simulated from the prototype of 15-story building, Two 1/2 scaled precast concrete wall specimens and one monolithic reinforced concrete specimen were designed and tested under the cyclic loading conditions. The main parameter of test specimens in PC large panel structure is the type of details for vertical continuity of vertical steel in horizontal joint. Also the behaviors of PC large panel structures are compared with that of monolithic reinforcement concrete wall structure. From the results, the stiffness and energy dissipation ratio of the precast concrete specimens are shown little bit lower than those of monolithic reinforced concrete specimen. In the PC large panel structures, the specimen connected vertically by welding (strong connection) showed higher strength than that of the specimen connected vertically by joint box. However the failure pattern of the former showed more brittle than that of the latter due to the diagonal compressive failure of wall panels.

  • PDF

철근콘크리트 프리캐스트 대형판 접합부의 설계 및 해석 (Design and Analysis on The Connections of RC Precast Large Panel)

  • 박강근
    • 한국공간구조학회논문집
    • /
    • 제6권2호
    • /
    • pp.85-92
    • /
    • 2006
  • 본 연구에서는 철근콘크리트 프리캐스트 대형판의 접합부 설계방법 및 해석방법에 대해서 연구를 수행하였다. 접합부의 설계방법은 수평접합부와 수직접합부의 구조적 거동에 대한 안정성 및 일체성을 확보하기 위한 설계법을 제시하였고, 접합부의 해석은 강체스프링 모델에 의한 탄소성해석을 수행 하였다.

  • PDF

강체요소법에 의한 철근 콘크리트 프리캐스트 대형판 접합부의 탄소성해석 (Elasto-plastic Analysis of Reinforced Concrete Precast Large Panel Connections by Rigid Element Method)

  • 박강근;김용태;권택진
    • 한국공간구조학회논문집
    • /
    • 제1권2호
    • /
    • pp.111-116
    • /
    • 2001
  • This paper is a study on the elasto-plastic analysis of reinforced concrete precast large panel connections by rigid element spring model. In the analysis of rigid element spring model, each collapsed part or piece of structures at limiting state of loading is assumed to behave like rigid bodies. The present author propose new elements for the improement and expansion of the rigid element spring model. In this study, it is proposed how the rigid element method can be applied to the elesto-plastic analysis of precat large panel connections. Some numerical results of analytical modeling and load displacement curves are shown.

  • PDF

수평 접합부를 고려한 프리캐스트 대형판 구조물의 동적 해석에 관한 연구 (Dynamic Analysis of Precast Concrete Large Panel Structures with Horizontal Joints)

  • 정일영;송진규;강해관
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.249-257
    • /
    • 1996
  • Dynamic Analysis of Precast Concrete Large Panel Structures with Horizontal Joints The damage in precast large panel structures subjected to destructive earthquakes is generally localized in the joints. Particularly, the horizontal joints influence on the stability and integrity of the overall structure. In this research a dynamic analysis was carried out by the macro model that idealized the horizontal joints as inelastic-nonlinear spring systems. It is capable of simulating the behavior of precast concrete structures using the mathematical model. As a result of the dynamic parametric study for the case of 0.12g peak base accelerations, it is found that all joints behave elastically for sliding and opening and that all forces are well distributed without excessive local concentration on my horizontal joints.

  • PDF

P.C 대형판넬 부분구조물의 Quasi-Static 실험연구 (Quasi-Static Test of Precast Concrete Large Panel Subassemblage)

  • 최정수;이한선;김우;홍갑표
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.73-78
    • /
    • 1990
  • Large panel building systems are composed of vertical wall panels which support horizontal roof and floor panels to form a box like structure. The simplecity of the connections, which makes precast concrete economically viable, causes a lack of continuity in stiffness, strength and ductility. This precast concrete large panel systems typically have weak connection regions. Three types of 2-story full-scale precast concrete subassemblages were tested under reversed cyclic loading. The seismic resistance capacity and failure mode of each system are compared in connection with the characteristics of joint connection details.

  • PDF

Seismic behavior of post-tensioned precast reinforced concrete beam-to-column connections

  • Cheng, Chin-Tung
    • Computers and Concrete
    • /
    • 제5권6호
    • /
    • pp.525-544
    • /
    • 2008
  • In this research, the self-centering effect in precast and prestressed reinforced concrete structures was investigated experimentally. The reinforced concrete beams and columns were precast and connected by post-tensioning tendons passing through the center of the beams as well as the panel zone of the connections. Three beam-to-interior-column connections were constructed to investigate parameters such as beam to column interfaces (steel on steel or plastic on plastic), energy dissipating devices (unbonded buckling restrained steel bars or steel angles) and the spacing of hoops in the panel zone. In addition to the self-centering effect, the shear strength in the panel zone of interior column connections was experimentally and theoretically evaluated, since the panel zone designed by current code provisions may not be conservative enough to resist the panel shear increased by the post-tensioning force.

프리캐스트 콘크리트 대형 패널을 이용한 조립식 아파트 공사 (Prefabricated Apartments Project Using Precast Concrete Large Panel System)

  • 박의식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1989년도 가을 학술발표회 논문집
    • /
    • pp.49-52
    • /
    • 1989
  • This report introduces the large scale prefabricated apartment project in Saudi Arabia designed and built by Hyundai Engineering and construction Co. as turn-key basis from ministry of Public works and ltousing of Saudi Arabia. This project using precast large panel system is 7,600 dwelling unit, total building area 1.8 mil sguare meters. Large panel system is a kind of industrialized building method which classified as monolithic system, total system and structural system. Hyundai Engineering and Construction Co. develop his own prefabricated large panel system for this project and named "HYUNDAI SYSTEM". The key point of this system is vertical and horizontal joints between panels. Also stability of whole building structure is especially important for this kind of prefabricated building. building.

  • PDF

대형재하시험을 통한 원지반 부착식 패널옹벽의 거동특성 (Behavior Characteristics of Precast Concrete-Panel Retaining Wall Adhered to In-situ Ground through Large Scaled Load Test)

  • 신윤철;민경남;김진희;안태봉
    • 한국지반환경공학회 논문집
    • /
    • 제17권11호
    • /
    • pp.45-53
    • /
    • 2016
  • 패널식 옹벽은 지보재를 통한 선지보 개념으로 프리캐스트 패널과 체결하여 원지반 강도를 최대한 보호하며 보강하는 공법이다. 최근 건설공사에서 대규모 깎기비탈면의 형성에 따른 토공량 증가와 환경 훼손을 최소화하고 용지제한에 따른 토지의 효율적인 이용을 위해 패널식 옹벽의 적용이 증가하고 있는 추세이다. 원지반 부착식 패널옹벽은 자연암반 질감을 갖는 프리캐스트 콘크리트 패널을 사용하여 경관성을 향상시키고 완전한 Top-Down 시공법을 구현하도록 개발된 공법으로 수직절취와 패널의 원지반 직접부착이 가능해 비탈면 이완을 최소화하고 터파기 및 되메우기 공종을 배제하여 시공성을 개선하였다. 본 연구는 현장시험시공을 수행하여 수직절취 및 Top-Down에 대한 시공성을 확인하고, 대형재하시험과 하중단계별 계측결과를 분석하여 원지반 부착식 패널옹벽의 거동특성을 분석하였다.

수직접합부 강성을 고려한 프리캐스트 콘크리트 대형판구조물의 응력해석 (Stress Analysis of Precast Concrete Large Panel Structures Taking Account of Stiffness of Vertical Joints)

  • 장극관;이한선;신영식;류진호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 가을 학술발표회논문집
    • /
    • pp.149-156
    • /
    • 1993
  • Precast concrete (P.C.) large panel structures have usually weaker stiffness at joints than that of monolithic in-situ reinforced concrete structures. But structural designers do not in general take into account this characteristics of P. C. large panel structures and use the same analytical models as for the monolithic structure. Therefore, the results of analysis obtained by using these models may be quite different from those actually occuring in real P.C. structure. In this study, the change in force and stress distribution and deflections of structure caused by applying lower shear stiffness at vertical joints are investigated through trying several finite element modeling schemes specific for P.C. structures. Finally, for engineers in practice. a simplified model, which takes account of the effect of lower shear stiffness at vertical joints, is proposed with the understanding on possible amount of errors.

  • PDF