• Title/Summary/Keyword: pre-source

Search Result 529, Processing Time 0.026 seconds

The manufacture of pre-amplifier for measuring the electrical signal of human body (인체 전기 신호 계측을 위한 pre-amplifier의 제작)

  • 박종환;천우영;박형준;박병림
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.179-182
    • /
    • 1997
  • In this study, the pre-amplifiers were manufac-tured, which correspinds with the properties of signal source, For measuring the EMG, EEG, ECG and EOG's signal, which are generated at human body, the pre-amplifiers were manufactured in this studywhich was corresponding with the propertiies of dach signal source. So as to do, the bandwidth of filters and the amplitude of amplifiers were adaptively adjusted, according to signal source. Then, the usefulness was represented by showing the measured examples.

  • PDF

Case Study on Application of Ground Heat Source in Thermal Labyrinth by CFD Model (CFD 모델을 이용한 열미로의 지중열원 활용에 관한 사례 연구)

  • Min, Joon-Ki;Nam, Sun-Young
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • In order to evaluate the performance of ground heat source in thermal labyrinth on pre-heating in winter season and pre-cooling in summer season, the followings are made as a conclusion through case study of H project by using the weather data from Korea meteorological administration and CFD model. By making outdoor air inlet via ground heat source in thermal labyrinth for conduction, convection and etc., the temperature rise is $13.4^{\circ}C$as the effect of pre-heating in winter season. On the other hand, as the effect of pre-cooling in summer season, the temperature decrease is $7.2^{\circ}C$. The energy saving rate by the application of ground heat source in thermal labyrinth is 9.1%.

A Study on the Simplified Economics Evaluation Method for Selecting a Heat Source System at the Pre-design Phase (초기계획단계에서 열원시스템 선정을 위한 경제성 간이 평가법에 관한 연구)

  • Park Yool;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1060-1067
    • /
    • 2004
  • To apply an analysis method of life cycle cost when assessing economics of equipment system, we should basically set up preconditions such as useful life, price escalation rate, interest rate, etc. as well as consider a calculation algorism of source energy and heat source system, which is a complex process for life cycle costing. For this reason, equipment designers tend to plan heat source systems, without a thorough investigation on economics of alternative systems at the pre-design phase. In this process, architectural designers should adopt a proper heat source system, which is one of the most important factors for planning an appropriate architectural design, through a discussion with equipment designers in a short time. In order to offer an evaluation method for equipment designers to analyze economics of an alternative heat source system easily at the pre-design phase, this research would define the simplified economics, evaluation method through analysis of existing papers for economics evaluation, and examine validity through comparison of simplified method values ($LCC_{EC}$) and life cycle costing values ($LCC_{15}$) for six alternative heat source systems.

Source Location of Multiple Impacts on the Plate Based on Pre-signal Processing (전치 신호처리를 통한 평판에서의 다중 충격의 위치 추적에 관한 연구)

  • Moon, Yoo-Sung;Park, Hong-Sug;Lee, Sang-Kwon;Shin, Ki-Hong;Lee, Yung-Sup
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.3
    • /
    • pp.220-226
    • /
    • 2011
  • This paper presents the novel work for source localization of serial multiple impacts in a plate sructure. It is difficult to identify the source of serial multiple impacts with the current source localization techenology(SLT) because of the overlapping of dispersive wave induced by multiple impacts and the reflaction from the edge of the plate. In this paper, the new method is suggested for source localization. The method is developed based on the SLT with pre-signal processing such as some limitation for the selection of three sensors, the frequency range for TFA and impact time interval. Results from numerical simulation and experiment in isotropic plate structure are presented, which show the capability of the proposed method.

Performance Variation of a Combined Cycle Power Plant by Coolant Pre-cooling and Fuel Pre-heating (냉각공기 예냉각과 연료예열에 의한 복합발전 시스템의 성능변화)

  • Kwon, Ik-Hwan;Kang, Do-Won;Kim, Tong-Seop;Kim, Jae-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.57-63
    • /
    • 2012
  • Effects of coolant pre-cooling and fuel pre-heating on the performance of a combined cycle using a F-class gas turbine were investigated. Coolant pre-cooling results in an increase of power output but a decrease in efficiency. Performance variation due to the fuel pre-heating depends on the location of the heat source for the pre-heating in the bottoming cycle (heat recovery steam generator). It was demonstrated that a careful selection of the heat source location would enhance efficiency with a minimal power penalty. The effect of combining the coolant pre-cooling and fuel pre-heating was also investigated. It was found that a favorable combination would yield power augmentation, while efficiency remains close to the reference value.

Potential Water Retention Capacity as a Factor in Silage Effluent Control: Experiments with High Moisture By-product Feedstuffs

  • Razak, Okine Abdul;Masaaki, Hanada;Yimamu, Aibibula;Meiji, Okamoto
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.4
    • /
    • pp.471-478
    • /
    • 2012
  • The role of moisture absorptive capacity of pre-silage material and its relationship with silage effluent in high moisture by-product feedstuffs (HMBF) is assessed. The term water retention capacity which is sometimes used in explaining the rate of effluent control in ensilage may be inadequate, since it accounts exclusively for the capacity of an absorbent incorporated into a pre-silage material prior to ensiling, without consideration to how much the pre-silage material can release. A new terminology, 'potential water retention capacity' (PWRC), which attempts to address this shortcoming, is proposed. Data were pooled from a series of experiments conducted separately over a period of five years using laboratory silos with four categories of agro by-products (n = 27) with differing moisture contents (highest 96.9%, lowest 78.1% in fresh matter, respectively), and their silages (n = 81). These were from a vegetable source (Daikon, Raphanus sativus), a root tuber source (potato pulp), a fruit source (apple pomace) and a cereal source (brewer's grain), respectively. The pre-silage materials were adjusted with dry in-silo absorbents consisting wheat straw, wheat or rice bran, beet pulp and bean stalks. The pooled mean for the moisture contents of all pre-silage materials was 78.3% (${\pm}10.3$). Silage effluent decreased (p<0.01), with increase in PWRC of pre-silage material. The theoretical moisture content and PWRC of pre-silage material necessary to stem effluent flow completely in HMBF silage was 69.1% and 82.9 g/100 g in fresh matter, respectively. The high correlation (r = 0.76) between PWRC of ensiled material and silage effluent indicated that the latter is an important factor in silage-effluent relationship.

Improving TCP Performance through Pre-detection of Route Failure in Mobile Ad Hoc Networks (Ad Hoc 망에서 경로단절 사전감지를 통한 TCP 성능향상)

  • Lee Byoung-Yeul;Lim Jae-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.11B
    • /
    • pp.900-910
    • /
    • 2004
  • Route failure is mainly caused by mobility of mobile host in ad hoc networks. Route failure, which may lead to sudden packet losses and delays, is losing the route from source to destination. In this situation, TCP assumes that congestion has occurred within the network and also initiates the congestion control procedures. Congestion control algorithm provides the means for the source to deal with lost packets. TCP performance in ad hoc environments will be degraded as TCP source cannot distinguish congestion from route failure. In this paper, we propose TCP-P as pre-detection approach to deal with route failure. TCP-P freezes TCP through pre-detection of route failure. Route failure information of the proposed mechanism is obtained not by routing protocol but by MAC protocol. The intermediated node, obtaining route failure information by its MAC layer, relays the information to TCP source and lets TCP source stop the congestion control algorithm. Results reveal that TCP-P responding with proactive manner outperforms other approaches in terms of communication throughput under the presence of node mobility.

A Study on the Performance Characteristics of a Heat Pump System using Stack Wast Heat in Fuel Cell Vehicles (스택 폐열을 이용한 연료전지 자동차용 열펌프 시스템의 성능 특성에 관한 연구)

  • Jeon, Byungyong;Ko, Wonbin;Park, Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.325-330
    • /
    • 2016
  • This study was conducted to develop a heating system for a fuel cell-driven electric vehicle. The system consists of a compressor, an expansion device and three heat exchangers. A conventional air source heat exchanger is used as primary heat exchanger of the system, and an additional water source heat exchanger is used as a pre-heater to supply heat to the upstream air of the primary heat exchanger. On the other hand, the third heat exchanger consists of a water-to-refrigerant heat exchanger. The heat source of the pre-heater and the water-refrigerant heat exchanger is the waste heat from the fuel cell's stack. In the experiment, the indoor and the outdoor air temperature were fixed, and the compressor speed, EEV opening and waste heat temperature were varied. The results indicate that the $COP_h$ of the proposed system is 3.01 when the system is operating at a 1,200 rpm compressor speed, 50% EEV opening, and $50^{\circ}C$ waste heat source temperature in air pre-heater operation. However, when the system uses a water-refrigerant heat exchanger, the $COP_h$ increases to up to 9.42 at the same compressor speed and waste heat source temperature with 75% EEV openings.

The Effects of the Space Perception Ability and Creative Personality 'Source of Season Change' Using Small Inquiry Method (소집단 탐구기법을 활용한 '계절의 변화 원인' 학습이 공간지각 개념 및 창의적 인성에 미치는 효과)

  • Lee, Yong-Seob
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.5 no.3
    • /
    • pp.307-315
    • /
    • 2012
  • The purpose of this study was to examine the effects of small inquiry method on space perception ability and creative personality. Testees of this research are 36 elementary pre-service teachers taking an astronomical observation class. Doing inquiry activity after 36 elementary pre-service teachers are classified into 6 Jigsaw small inquiry. Learning activity was split into two groups, expert group and a population. To find out research outcome, pre-test was executed space perception ability test, creative personality test. Analysis of test result was accomplished with statistical package SPSS 18.0 paired t testing hypothesis. The results of this study are as follows. First, 'source of season change' class using Jigsaw small inquiry method has effect on space perception ability improvement. This was interpreted that space perception ability improvement was effective because characteristic of Jigsaw small inquiry is made up of lots of semin Second, 'source of season change' class using Jigsaw small inquiry method has no effect on creative personality. This was interpreted that experiment and discussion activity getting accomplished in a short time has no effect on qualitative characterizing Creative Personality improvement.

Identification of multiple sources in a plate structure using pre-filtering process for reduction of interference wave

  • Lee, S.K.;Moon, Y.S.;Park, J.H.
    • Smart Structures and Systems
    • /
    • v.8 no.2
    • /
    • pp.219-237
    • /
    • 2011
  • This paper presents novel research into the source localization of multiple impacts. Source localization technology for single impact loads in a plate structure has been used for health monitoring. Most of research on source localization has been focused only on the localization of single impacts. Overlapping of dispersive waves induced by multiple impacts and reflection of those waves from the edge of the plate make it difficult to localize the sources of multiple impacts using traditional source localization technology. The method solving the overlapping problem and the reflection problem is presented in the paper. The suggested method is based on pre-signal processing technology using band pass filter and optimal filter. Results from numerical simulation and from experimentation are presented, and these verify the capability of the proposed method.