• Title/Summary/Keyword: pre-signal

Search Result 720, Processing Time 0.033 seconds

The manufacture of pre-amplifier for measuring the electrical signal of human body (인체 전기 신호 계측을 위한 pre-amplifier의 제작)

  • 박종환;천우영;박형준;박병림
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.179-182
    • /
    • 1997
  • In this study, the pre-amplifiers were manufac-tured, which correspinds with the properties of signal source, For measuring the EMG, EEG, ECG and EOG's signal, which are generated at human body, the pre-amplifiers were manufactured in this studywhich was corresponding with the propertiies of dach signal source. So as to do, the bandwidth of filters and the amplitude of amplifiers were adaptively adjusted, according to signal source. Then, the usefulness was represented by showing the measured examples.

  • PDF

Fabrication of High Precision Pre-amplifier for EEG Signal Measurement and Development of Auto Classification System (뇌파신호 측정을 위한 고성능 전치증폭기 제작 및 자동 신호분류 시스템 개발)

  • 도영수;장긍덕;남효덕;장호경
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.409-412
    • /
    • 2000
  • A high performance EEG signal measurement system is fabricated. It consists of high precision pre-amplifier and auto identification bandwidth unit. High precision pre-amplifier is composed of signal generator, signal amplifier with a impedance converter, body driver and isolation amplifier. The pre-amplifier is designed for low noise characteristics, high CMRR, high input impedance, high IMRR and safety, Auto identification bandwidth unit is composed of AD-converter and PIC micro-controller for real time processing EEG signal. The performance of EEG signal measurement system has been shown the classified bandwidth through the clinical demonstrations.

  • PDF

A Design Method for Pre-Distortion Compensation of SAR Chirp Signal based on Envelop Sampling and Interpolation Filter (위성 탑재 영상레이다 첩 신호의 전치왜곡 보상을 위한 포락선 샘플링 및 보간 필터 기반의 설계 기법)

  • Lee, Young-Bok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.347-354
    • /
    • 2022
  • The synthetic aperture radar(SAR) is an equipment that can acquire images in all weathers day and night based on radar signals. The on-board processor of satellite SAR generates transmission signal by digital signal processing, converts it into an analog signal and transmits to antenna. Until the transmission signal generated by on-board processor is output, the signal passes the transmission cables and analog devices. At this time, these hardware distort the signal and makes SAR performance worse. To improve the performance, pre-distortion technique is used. But, general pre-distortion using taylor series is not sufficient to compensate for the distortion. This paper suggests transmit signal design method with improved pre-distortion. This paper uses envelop sampling method and interpolation filter for frequency domain compensation. The proposed method accurately compensates the hardware distortion and reduces resource usage of FPGA. To analyze proposed method's performance, IRF characteristics are compared when the proposed method applies to signal with errors.

A Study on a New Pre-emphasis Method Using the Short-Term Energy Difference of Speech Signal (음성 신호의 다구간 에너지 차를 이용한 새로운 프리엠퍼시스 방법에 관한 연구)

  • Kim, Dong-Jun;Kim, Ju-Lee
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.12
    • /
    • pp.590-596
    • /
    • 2001
  • The pre-emphasis is an essential process for speech signal processing. Widely used two methods are the typical method using a fixed value near unity and te optimal method using the autocorrelation ratio of the signal. This study proposes a new pre-emphasis method using the short-term energy difference of speech signal, which can effectively compensate the glottal source characteristics and lip radiation characteristics. Using the proposed pre-emphasis, speech analysis, such as spectrum estimation, formant detection, is performed and the results are compared with those of the conventional two pre-emphasis methods. The speech analysis with 5 single vowels showed that the proposed method enhanced the spectral shapes and gave nearly constant formant frequencies and could escape the overlapping of adjacent two formants. comparison with FFT spectra had verified the above results and showed the accuracy of the proposed method. The computational complexity of the proposed method reduced to about 50% of the optimal method.

  • PDF

The Design of High Precision Pre-amplifier for EEG Signal Measurement (뇌파신호 측정을 위한 고정밀 전치 증폭기의 설계)

  • 유선국;김남현
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.301-308
    • /
    • 1995
  • A high-precision pre-amplifier is designed for general use in EEG measurement system. It consists of signal generator, signal amplifier with a impedance converter, shield driver, body driver, differential amplifier, and isolation amplifier. The combination of minimum use of inaccurate passive components and the appropriate matching of each monolithic amplifiers results in good noise behavior, low leakage current, high CMRR, high input impedance, and high IMRR. The performance of EEG pre-amplifier has been verified by showing the typical EEG pattevn of a nomad person through the clinical experiments.

  • PDF

Estimation of Accident Effectiveness Based Upon the Location of Traffic Signal Using C-G Method (C-G Method를 활용한 신호등 위치에 따른 교통사고 효과 분석)

  • Kim, Jeong Hyun;Kim, Gyu Ho;Kim, Jang Wook;Lee, Soo Beom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6D
    • /
    • pp.775-789
    • /
    • 2008
  • The Office for Government Policy Coordination announced in 2006, september that a scheme of pre-signal would show remarkable outcome to reduce traffic accidents. Therefore, the Ministry recommended applying preferentially the pre-signal scheme to enhancement projects for high accident frequency areas. In case that the suggested pre-signal was unilaterally introduced to the enhancement projects at intersections, it might rather cause a big trial and error in terms of traffic safety. Hence, on the basis of quantitative analysis, this study was to indicate a pre-signal's effectiveness to reduce the traffic accidents, to illustrate a trend of the accident type due to the pre-signal, and to introduce intersection type that could be appropriate for the pre-signal. The methodology adopted Comparison-Group Method which was developed by Hauer. Through this methodology, overall effectiveness to reduce the accidents is considered positive but individual effectiveness by intersection and by accident case was different. All cases of the accidents at small scale intersection demonstrated positive results to reduce its accidents, while in case of frontal collision and side-right angle collision out of the accident types, the installation of pre-signal rather caused a negative result increasing the accident in terms of the traffic safety. I hope that this study would be a useful reference for future development of the estimation of accident effectiveness. Thus, when the pre-signal is being installed in the big intersection, it is recommended operating the installation concerning carefully improvements about muliple aspects as traffic operation, traffic facility, human factor etc.

High Level Expression of a Protein Precursor for Functional Studies

  • Gathmann, Sven;Rupprecht, Eva;Schneider, Dirk
    • BMB Reports
    • /
    • v.39 no.6
    • /
    • pp.717-721
    • /
    • 2006
  • In vitro analyses of type I signal peptidase activities require protein precursors as substrates. Usually, these pre-proteins are expressed in vitro and cleavage of the signal sequence is followed by SDS polyacrylamide gel electrophoresis coupled with autoradiography. Radioactive amino acids have to be incorporated in the expressed protein, since the amount of the in vitro expressed protein is usually very low and processing of the signal peptide cannot be followed by SDS polyacrylamide gel electrophoresis alone. Here we describe a rapid and simple method to express large amounts of a protein precursor in E. coli. We have analyzed the effect of ionophors as well as of azide on the accumulation of expressed protein precursors. Azide blocks the function of SecA and the ionophors dissipate the electrochemical gradient across the cytoplasmic membrane of E. coli. Addition of azide ions resulted in the formation of inclusion bodies, highly enriched with pre-apo-plastocyanine. Plastocyanine is a soluble copper protein, which can be found in the periplasmic space of cyanobacteria as well as in the thylakoid lumen of cyanobacteria and chloroplasts, and the pre-protein contains a cleavable signal sequence at its N-terminus. After purification of cyanobacterial pre-apo-plastocyanine, its signal sequence can be cleaved off by the E. coli signal peptidase, and protein processing was followed on Coomassie stained SDS polyacrylamide gels. We are optimistic that the presented method can be further developed and applied.

Development of the Pre-amplifier and the DSP Board for the Potable EEG Biofeedback System (포터블 뇌파 바이오피드백 시스템을 위한 전치증폭기 및 DSP 하드웨어의 설계)

  • Lee, Kyoung-Il;Ahn, Bo-Sep;Park, Jeong-Je;Lee, Seung-Ha;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.121-127
    • /
    • 2003
  • In this study, we carried out a study for implementation of the pre-amplifier and the digital signal processing part for the potable EEG biofeedback system. As we consider characteristics of the EEG signal, we designed the pre-amplifier to obtain the EEG signal to be reduced noise signal. Because the EEG signal include EOG, EMG, ECG signals etc, it is difficult to analyze of the EEG signal. Therefore, we developed DSP board and operation program which was embed the LMS adaptive filter algorithm and operate with the pre-amplifier in the real time. The simulation signal and pure EEG signal is used in the experiment. As the result, we confirmed good efficiency of developed system and possibility of application to the portable EEG biofeedback system.

Digital Pre-distorter for Communication Transmitters (통신용 송신기의 디지털 Pre-distorter)

  • 한동석;김용정김대진김창주
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.211-214
    • /
    • 1998
  • The high power amplifier (HPA) for broadcasting transmitter systems has nonlinear property in terms of input signal power. Hence, it produces AM/AM and AM/PM modulation to the modulated signal. Therefore, the non-linearity results in bandwidth expansion and nonlinear distortion to in-band signal. In this paper, we propose a simple sain-based predistorter that requires less computational burden and less time for the full initialization of the pre-distorter ROM table.

  • PDF

Optimization-based Real-time Human Elbow Joint Angle Extraction Method (최적화 기반 인간 팔꿈치 관절각 실시간 추출 방법)

  • Choi, Young-Jin;Yu, Hyeon-Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.12
    • /
    • pp.1278-1285
    • /
    • 2008
  • An optimization-based real-time joint angle extraction method of human elbow is proposed by processing the biomedical signal of surface EMG (electromyogram) measured at the center point of biceps brachii. The EMG signal is known as non-stationary (time-varying) signal, but we assume that it is quasi-stationary because a physical or physiological system has limitations in the rate at which it can change its characteristics. Based on the assumption, a pre-processing method to obtain pre-angle values from raw EMG signal is firstly suggested, and then an optimization method to minimize the error between the pre-angle and real joint angle is proposed in this paper. Finally, we suggest the experimental results showing the effectiveness of the proposed algorithm.