• Title/Summary/Keyword: pre-set

Search Result 982, Processing Time 0.028 seconds

Explosion Bulge Test Underwater of 800MPa Grade Pre-heat Free Welding Plate (800MPa급 무예열 용접 판재의 수중 폭파변형시험)

  • Park, Tae-Won;Song, Young-Beum;Kim, Jin-Young;Yang, Sung-Ho;Park, Chul-Gyu;Seo, Jun-Suck;Kim, Hee-Jin
    • Journal of Welding and Joining
    • /
    • v.28 no.6
    • /
    • pp.63-69
    • /
    • 2010
  • The pre-heat free consumables for GMAW, SAW and FCAW processes that matche with the Cu-bearing PFS-700 steel which has yield strength over 700MPa were developed and evaluated to see the suitability in military such as submarine and battle ship. Explosion Bulge Test underwater was developed and applied to see the reliability of welded structure. All welding was conducted without pre-heat before welding, the interpass temperature was below $150^{\circ}C$ for all welding conditions. Tensile strength for the weld metal in GMAW, SAW and FCAW process is 887MPa, 875MPa and 813MPa, respectively, these values are similar to the base metal of PFS-700 steel of 838MPa. EBT results in GMAW, SAW and FCAW show 14.0%, 14.02% and 15.9% reduction of thickness without generation of crack, respectively and stand-off distance was set up properly to have over 14.0% reduction of thickness. Through EBT results, the developed new consumables are applicable to the weapon systems such as submarine and battle ship.

Explosion Bulge Test in Underwater of 800MPa Grade Pre-Heat Free Welding Plate (800MPa급 무예열 용접 판재의 수중 폭파변형시험)

  • Park, Tae-Won;Song, Young-Bum;Kim, Jin-Young;Yang, Seong-Ho;Hong, Sung-Suk;Shim, In-Ok;Park, Chul-Kyu;Kim, Hee-Jin
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.63-63
    • /
    • 2010
  • The pre-heat free consumables for GMAW, SAW and FCAW processes that matches the Cu-bearing PFS-700 steel which has yield strength over 700MPa were developed and evaluated to see the suitability in military such as submarine and battle ship. Explosion bulge test in underwater was developed and applied to see the reliability of welded structure. All welding was conducted without pre-heat before welding, the interpass temperature was below $150^{\circ}C$ for all welding conditions. Tensile strength for the weld metal in GMAW, SAW and FCAW process is 887MPa, 875MPa and 813MPa, respectively, these values are similar to the base metal of PFS-700 steel of 838MPa. EBT results in GMAW, SAW and FCAW show 14.0%, 14.02% and 15.9% reduction of thickness without generation of crack, respectively and stand-off distance was set up properly to have over 14.0% reduction of thickness. Through EBT results, the developed new consumables are applicable to the weapon systems such as submarine and battle ship.

  • PDF

Effect of Properties of Repair Mortars According to Pre-mixing Methods (원료 사전 혼합 방법에 따른 보수 모르타르의 물성에 대한 영향)

  • Shin, Dong-Cheol;Kang, Yong-Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.104-109
    • /
    • 2017
  • It is important to keep the distribution of the raw material mixture constant, in order to maximize the effect of the pre-mix type repair mortar, and it is also necessary to increase the performance of the mixer in order to minimize the deviation of the product. In this study, three kinds of mixer used in production sites were used to make repair mortar and the properties of each mortar were examined. As a result, it is confirmed to the difference in properties of pre-mix type repair mortar differ depending on the type of mixer, and the fluidized zone mixer showed relatively good results. In addition, it is preferable to set the mixing time to about 10 minutes to 15 minutes in order to ensure workability and optimum physical properties.

Numerical and experimental investigation of conventional and un-conventional preswirl duct for VLCC

  • Shin, Hyun-Joon;Lee, Jong-Seung;Lee, Kang-Hoon;Han, Myung-Ryun;Hur, Eui-Beom;Shin, Sung-Chul
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.3
    • /
    • pp.414-430
    • /
    • 2013
  • This paper shows the study of preswirl duct as an effective energy saving devices that have been devised and reviewed to support the propeller performance, especially for the ship of VLCC with large block coefficients. From the bare hull wake measurements, typical upper/lower asymmetry of hull wake at the propeller disk was found. The 2 kinds of pre-swirl duct, Unconventional half circular duct and Conventional circular pre-swirl duct have been designed and reviewed to recover the loss of propeller running in that condition. The general function of the pre-swirl duct was set to work against this asymmetry of wake and generate pre-swirled flow into the propeller against the propeller rotating direction. The optimum self propulsion tests with various angle configurations were carried out and the best configuration was decided. Accordingly, cavitation test was carried out with best configuration of unconventional half circular duct. The blade surface and tip vortex cavitation behaved smoother when the duct was mounted. The hull pressure amplitudes reflected this difference, so the hull pressure amplitude with duct was smaller than that of without duct.

Implementation of ATE to Maintain Pre-Amplifier of Thermal Imaging System (열상장비 전단증폭부 정비용 ATE의 구현)

  • Park, Jai-Hyo;Kim, Han-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.80-87
    • /
    • 2012
  • We have developed the ATE(Automatic Test Equipment) system for the performance test of pre-amplifier of thermal imaging devices. The device regenerates the electronic signals of photon detection module which is normally in weak energy, for the image signals processing. Previous ATE system was primarily and actively developed in the field of semiconductor devices quality parts inspection. Recently, it has been studied in the field of performance testing of equipment. In the field of thermal performance test equipment, however, it lacks the study of ATE compared to other areas, which causes the maintenance related to the core of military thermal imaging system maintenance to be limited. In this paper, a new study of ATE in the field of thermal imaging system is done. It is designed to be used universally for the ATE system with different types of circuit card of thermal imaging system by adopting matrix relays. Using the developed ATE measuring the pre-amplifier amplitude, an average amplified amplitude of 2.71Vpp was measured which confirms that it is within the range of theoretical analysis and also verifies the good performance of the developed ATE.

A Study on the Actual Profile of Emergency Medical Personnel's Pre-admission Infection Control - Based on Jeollabuk-do provincial area - (병원 전 응급의료종사자의 감염관리 실태 연구 - 전북지역 중심으로 -)

  • Shin, Sang-Yol;Jeong, Tae-Oh
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.2
    • /
    • pp.19-27
    • /
    • 2007
  • Purpose: By identifying the actual profile of emergency medical personnel's pre-admission infection control practices, this study intended to provide a basic reference material for the improvement and reorientation of pre-admission infection control measures, and thereby help establish an effective plan for pre-admission infection control activities. Methods: Total 119 EMT's working for Jeollabuk-do Provincial Fire Defense HQ were asked to join a structured questionnaire survey from June to August 2006. Results: 1. It was found that 56.1% respondents answered no guideline available on the prevention of infection. Out of our rescue brigade members who knew about relevant guideline available, 34.2% respondents answered that their department conducted quality control program for the guideline. 2. For protective outfit in emergency practice, it was found that most respondents put on gloves or nothing at all(38%), which was followed by sterile gloves(29.2%), disposable mask(26.9%), gown(4.3%) and protective goggle(1.6%). And it was noted that all respondents(100%) washed out any clothing contaminated with somatic secretion on their own. 3. For a question about any experience in emergency activities exposed to infectious diseases, it was found that most of all respondents(77.9%) answered 'No', which was followed by 'Don't Know'(18.6%) and Yes(3.9 %). 4. For a question about any experience in inquiring of patients about infectious diseases, it was found that most respondents(49.4%) answered 'Yes' and 'Sometimes'(9.1%). It was noted that 20.2% respondents had extra medical examination in medical institution in terms of whether they were exposed to infectious diseases, apart from regular medical examination. Conclusions: In order to protect 119 EMT's from infectious diseases, it will be necessary to acquire emergency medical staffs specializing in infection control and organize corresponding personnel training units to keep providing reorientation and evaluation. In addition, it will be also necessary to supply them with a full set personal protection apparatuses and other equipments required for disinfection and sterilization.

  • PDF

Immediate Effects of Myofascial Release Using Vibration Foam Rolling Methods on Hamstrings Range of Motion, Flexibility, Pressure Pain Thresholds and Dynamic Balance

  • Kim, Ho;Shin, Wonseob
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.2
    • /
    • pp.2042-2051
    • /
    • 2020
  • Background: Many trials have been conducted the methods and types of intervention of form rollers, but no research has been done yet that mixes the methods and types of intervention. Objectives: To analyze the effects of myofascial release on the improvement of range of motion (ROM), flexibility, pain pressure threshold, and balance. Design: Randomized controlled trial. Methods: All subjects measured ROM, flexibility, pressure pain threshold, and dynamic balance by pre-test. After pre-test, subjects were randomized that static-vibration foam rolling group (n=12), dynamic-vibration foam rolling group (n=12), general foam rolling group (n=12). For the intervention, 3 sets of 90 seconds were applied to each group, and rest time was set to 60 seconds between sets. In the post-test and follow-up test after 10 minutes, all three groups were measured the ROM, flexibility, pressure pain threshold, and dynamic balance. Results: The results of comparing ROM, flexibility, pressure pain thresholds, dynamic balance ability appeared higher significant difference in the pre-post-10 minutes follow up test in comparison between time in the intragroup (P<.001). As a result of comparing the change of pre-post-10 minutes follow up, static vibration foam rolling showed higher significant difference compared to control groups (P<.001). Conclusion: Through this study, when foam rolling is applied within the same intervention time, static foam rolling can be expected to have a better effect than the existing dynamic foam rolling as well as vibration foam roller can expect better effect than general foam rolling.

Effect of pre-hospital BLS simulation training on the paramedic's competency

  • Jung, Jun-Ho;Cho, Byung-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.1
    • /
    • pp.103-109
    • /
    • 2018
  • The purpose of the study is to investigate the effect of a simulation training of BLS in paramedics in pre-hospital situation. This a nonequivalence control quasi-experimental study. The study subjects were 8 paramedics of experimental group and 8 paramedics of control group in K fire department. An informed consent was written by the subjects after explaining of the purpose of the study. The study methods consisted of conventional education and practice training. The conventional education was done for 30 minutes and the practice training was taken by four trainees of one group and the instructor demonstrated Basic Iife Support (BLS) performance for three minutes. Each trainer peformed BLS for ten minutes. In the beginning of the course, two paramedics got off from the ambulance and performed BLS including 5 cycles of Cardiopulmonary Resuscitation (CPR). Soon after the BLS, another two paramedics performed pre-hospital BLS survey. The education was guided by two professors of emergency medical technology, two Basic Iife Support instructors, and two emergency rescue directors. Pre-hospital BLS was measured by a 5-point Likert scale. Higher score means higher performance skills. The data were analyzed using SPSS/WIN 22.0 program set at significance level of p<05. The effect of simulation education was much more significant than the conventional education in BLS. The simulation education is very important and effective in improving the clinical performance skills of paramedics than the conventional education. The simulation education can provide the virtual environment of cardiac arrest to the paramedics. In conclusion, the simulation education can provide the effective teaching methods for various practice performance skills and solution by critical thinking in the paramedics and healthcare providers in the future.

Feasibility Appraisal and Proposal of a Pile Driving Formula for Domestic Pre-bored Pile Management (국내 매입 말뚝 관리를 위한 항타공식 활용 가능성 평가 및 제안에 관한 연구)

  • Kim, Gunwoong;Seo, Seunghwan;Kim, Juhyong;Chung, Moonkyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.11
    • /
    • pp.71-84
    • /
    • 2023
  • In accordance with Korean structural foundation design standards, dynamic or static load tests are mandated for 1 to 3% of total piles. The construction quality of the remaining 97% to 99% of piles is determined through penetration measurements. This study aims to enhance the quality control of the majority of piles by adopting a pile driving formula that considers both penetration and hammer energy. The current challenge lies in adapting existing overseas driving formulas to the domestic site conditions, characterized by shallow weathered or soft rocks, and the prevalent use of pre-bored piles. To address this, the Modified Gates formula was refined using domestic dynamic load data, thereby improving its applicability to pile management. Despite employing fewer variables, the proposed formula demonstrates a comparable accuracy to dynamic loading tests in predicting the bearing capacity of pre-bored piles. Consequently, this formula holds promise for practical use in future pile quality management.

EFFECT OF MANDIBULAR SET BACK SURGERY ON VOLUMETRIC CHANGE AND BITE FORCE OF MASSETER MUSCLE (하악전돌증환자에서 악교정수술후 저작근의 부피 및 교합력의 변화)

  • Seol, Jung-Eun;Lee, Myung-Hwan;Kim, Chang-Soo;Hong, Jong-Rak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.300-305
    • /
    • 2008
  • Purpose: The purpose of our study was to evaluate the volume of pre- and post operative masseter muscle and bite force in mandibular prognathic patients treated with SSRO with the use of the 3D CT imaging technique and occlusal force meter. Materials and methods: The study group consisted of 12 patients with mandibular prognathism (5 males and 7 females) who underwent mandibular setback surgery (BSSRO) in the Department of Oral and Maxillofacial Surgery, Samsung medical center. Bite force was measured at pre op, post op 3, 6 and 12 months by occlusal force meter(GM10, Nagano Keiki, Japan) The preoperative CT examination of subjects was performed between one month prior to operation and one year after to operation. And muscle volume was measured. Result: As compared to preoperative measurements at 1 year postoperatively the masseter & internal pterygoid muscle volume were diminished (p<0.05) The bite force steadily recovered, so at postoperatively 6 months reached the preoperative level. And at 1 year after operation, the maximum bite force was significantly greater than preoperative levels. No significant correlation was presented between masseter muscle and bite force (p>0.05), internal pterygoid muscle and bite force (p>0.05). Conclusion: In this study, the results showed that volume and bite force of the masticatory muscles decreased significantly immediate after orthognathic surgery for mandibular set-back. However, reduction of maximum bite force disappears within 6 months after surgery.