• 제목/요약/키워드: pre-plating time

검색결과 7건 처리시간 0.02초

Optimal Pre-Plating Method of Chicken Satellite Cells for Cultured Meat Production

  • Kim, So-Hee;Kim, Chan-Jin;Lee, Eun-Yeong;Son, Yu-Min;Hwang, Young-Hwa;Joo, Seon-Tea
    • 한국축산식품학회지
    • /
    • 제42권6호
    • /
    • pp.942-952
    • /
    • 2022
  • To establish a pre-plating method of chicken satellite cells with high purity, pre-plating was performed under culture conditions of 37℃ and 41℃, and the pre-plating time was set from a total of 3 hours to 6 hours in consideration of the cell attachment time. The purity of the cells was confirmed by staining paired box protein 7 (Pax7) after proliferation, and Pax7 expression was the highest in culture flasks shaken for 2 hours after incubation at 41℃ for 2 hours to prevent the attachment of satellite cells (p<0.05). Also, when pre-plating and proliferation were performed at 37℃ and 41℃, the Pax7 expression rate was higher at 41℃. The differentiation capabilities of the three groups (T3, T6, and T7) with high Pax7 expression were compared and the fusion index (%) and myotube formation area (%) determined by myosin heavy chain (MHC) staining was calculated. The T6 and T7 groups, which were cultured at 41℃, showed significantly higher values than the T3 group (p<0.05). There was no significant difference in the expression of Pax7 and MHC between the T6 and T7 groups (p>0.05). These results suggest that pre-plating at 41℃ for a total of 4 hours was the most efficient in terms of cost and time for purifying chicken satellite cells for cultured meat.

Influence of processing parameters for adhesion strength of TiAlN films prepared by Arc Ion Plating

  • 주윤곤;;조동율;윤재홍
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2007년도 추계학술대회 논문집
    • /
    • pp.136-137
    • /
    • 2007
  • Wear resistant TiAlN thin film has been widely deposited on the surface of cutting and forming tools by using Arc Ion Plating. TiAlN films are deposited by the processes designed by the Taguchi L18 experimental design. The L18 experimental design is applied to achieve surface properties and adhesion. The deposition parameters are working pressure, substrate temperature, bias voltage, arc power and pre-sputtering bias voltage and time. The most influential parameters on surface properties and adhesion are substrate bias voltage, working nitrogen pressure and arc power. The optimal coating processes are obtained for surface properties and adhesion.

  • PDF

무전해 니켈 도금된 폴리스티렌 복합 입자 제조 및 도금 조건의 영향 (Preparation of Composite Particles via Electroless Nickel Plating on Polystyrene Microspheres and Effect of Plating Conditions)

  • 김병철;박진홍;이성재
    • 폴리머
    • /
    • 제34권1호
    • /
    • pp.25-31
    • /
    • 2010
  • 무전해 니켈 도금법을 사용하여 단분산 폴리스티렌 입자 표면에 니켈이 도금된 고분자 코어/금속 쉘의 복합 입자를 제조하였다. 단분산 입자는 분산중합으로 제조하였는데 사용한 분산매질의 종류에 따라 다양한 크기의 단분산 폴리스티렌 입자를 제조할 수 있었다. 그 중 직경 $3.4\;{\mu}m$ 크기의 단분산 폴리스티렌 입자를 선택하여 무전해 니켈 도금을 시도하였다. 니켈 도금에 영향을 미치는 도금 조건을 파악하기 위하여 활성화제인 $PdCl_2$의 농도, 착화제인 glycine의 농도와 니켈 도금액의 투여 시간에 따른 니켈 도금된 폴리스티렌 복합 입자의 모폴로지를 관찰하였다. 본 연구조건하에서는 $PdCl_2$의 농도 0.4 g/L, glycine 농도 1 M 이상인 경우 폴리스티렌 입자 위에 균일한 두께의 니켈층을 형성하였고 석출되는 니켈도 적었다. 도금 시간 2 시간 중에서 동일양의 도금액을 투여 속도를 달리하며 도금한 경우 모폴로지 상의 뚜렷한 차이는 없었으나 0.15 mL/min 속도로 1시간 동안 투여한 경우가 상대적으로 균일한 도금 특성을 보여 주었다.

파형전류전해에 의한 은-주석합금 전착층의 조성 및 현미경조직 (The Composition and the Microstructure of Pulse current electrodeposits of SilverTin alloy)

  • 예길촌;김용웅;김진수
    • 한국표면공학회지
    • /
    • 제26권5호
    • /
    • pp.245-254
    • /
    • 1993
  • The effects of pulse current electrolysis conditions on the composition and the microstructure of Ag-Sn alloy were studied by using a pyrophosphate bath. Both cathode current efficiency and throwing power of alloy deposits formed under pulse plating conditions, decreased with increasing mean current density, and lower than those under D.C. electrolysis condition. Tin content of Ag-Sn alloy decreased noticebly with in-creasing the mean current density, while it increased with the increase of On-time from 1 to 10 ms. The pre-ferred orientation of Ag-Sn alloy changed with increasing cathode overpotential in the sequence of (100)longrightarrow(100)+(111)longrightarrow(111) at $20^{\circ}C$ and (110)longrightarrow(111)longrightarrow(111)+(100) at $30^{\circ}C$. The effective crystal grain size of the alloy was decreased by decreasing temperature from $30^{\circ}C$ to $20^{\circ}C$ and the surface structure of them was related to the preferred orientation.

  • PDF

블록공중합체 나노패턴을 이용한 표면 플라즈몬 연구 (The Study of Surface Plasmonic Bands Using Block Copolymer Nanopatterns)

  • 유승민
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.88-93
    • /
    • 2017
  • 다양한 응용분야를 가진 국부적인 표면플라즈몬 공명 특성을 손쉽게 제어할 수 있는 기술 개발은 매우 중요하다. 또한, 금속 나노입자의 형태, 크기, 그리고 조합에 관한 세심한 조사는 공명특성과 금속 나노구조의 관계를 이해하는데 매우 유용하다. 본 논문은 블록공중합체 마이셀 박막필름으로부터 얻어진 금속나노입자 배열에 따른 국부적인 표면플라즈몬의 공명특성에 관한 연구이다. 우선 전통적인 방법의 블록공중합체 리소그라피를 통해 두 가지 다른, 점 형태 및 링 형태, 금 나노입자를 제조하였다. 그 다음 은거울 반응을 통하여 금 나노입자위에 은이 둘러 쌓이도록 금/은 이중금속 나노구조를 구현했다. 금속 나노 구조체 조절을 위해 에탄올 전처리, 은거울 반응 시간, 블록공중합체의 제거 유무 등의 공정변수를 변화시켰다. 초기 금 나노입자가 잘 제조된 경우 항상 금나노입자 표면에 적절히 은이 잘 형성되었고, 이는 UV-Vis 실험에서 각 금속나노 입자의 고유 플라즈몬 밴드인 금 525nm, 은 420nm에서 각각 나타났다. 하지만 최초 적은 양의 금 나노입자가 제조되었을 경우 은 도금 속도가 빨라져서, 초기 금 나노입자의 표면을 은이 완전히 덮었으며, 이는 UV-Vis 실험에서 금의 플라즈몬 밴드는 나타나지 않고, 은의 고유 플라즈몬 밴드만 420nm에서 나타났다. 블록공중합체로부터 미리 합성된 금나노입자 위에 은을 도금하는 방법은 국부적인 표면플라즈몬 특성을 면밀히 조사하는데 매우 유용하다.

The fibronectin concentration that optimally maintains porcine satellite cells

  • Jae Ho Han;Si Won Jang;Ye Rim Kim;Hoon Jang;Kwan Seob Shim;Hyun Woo Choi
    • Animal Bioscience
    • /
    • 제36권12호
    • /
    • pp.1889-1897
    • /
    • 2023
  • Objective: 'Cultured meat' has been suggested as means of solving the problems associated with overpopulation and gas emissions. Satellite cells are a major component in the production of cultured meat; however, these cells cannot be maintained in vitro over long periods. Fibronectin is a glycoprotein that affects biological processes such as cell adhesion, differentiation, and migration. Unfortunately, the characteristics of porcine satellite cells grown in a long-term culture when exposed to fibronectin-coated dishes are unknown. The objective of this study was to investigate the appropriate concentration of fibronectin coated dishes for proliferation and maintenance of porcine satellite cells at long-term culture. Methods: In this study, we isolated the satellite cells and fibroblast cells with pre-plating method. We next analyzed the cell doubling time, cell cycle, and rate of expressed paired box 7 (Pax7) and myogenic differentiation 1 (MyoD1) in porcine satellite cells cultured with 20 ㎍/mL of fibronectin-, gelatin-, and non-coated dishes at early and late passage. We then analyzed the proliferation of porcine satellite cells with various concentrations of mixed gelatin/fibronectin. We next determined the optimal concentration of fibronectin that would encourage proliferation and maintenance of porcine satellite cells in a long-term culture. Results: Doubling time was lowest when 20 ㎍/mL of fibronectin was used (as tested during an early and late passage). Levels of expressed Pax7 and MyoD1, assessed using immunocytochemistry, were highest in cells grown using fibronectin-coated dishes. The proliferation of gelatin/fibronectin mixed coatings had no significant effect on porcine satellite cells. The concentration of 5 ㎍/mL fibronectin coated dishes showed the lowest doubling time and maintained expression of Pax7. Conclusion: Fibronectin with 5㎍/mL effectively maintains porcine satellite cells, a discovery that will be of interest to those developing the next generation of artificial meats.

Risk Factors of Allogenous Bone Graft Collapse in Two-Level Anterior Cervical Discectomy and Fusion

  • Woo, Joon-Bum;Son, Dong-Wuk;Lee, Su-Hun;Lee, Jun-Seok;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.450-457
    • /
    • 2019
  • Objective : Anterior cervical discectomy and fusion (ACDF) is commonly used surgical procedure for cervical degenerative disease. Among the various intervertebral spacers, the use of allografts is increasing due to its advantages such as no harvest site complications and low rate of subsidence. Although subsidence is a rare complication, graft collapse is often observed in the follow-up period. Graft collapse is defined as a significant graft height loss without subsidence, which can lead to clinical deterioration due to foraminal re-stenosis or segmental kyphosis. However, studies about the collapse of allografts are very limited. In this study, we evaluated risk factors associated with graft collapse. Methods : We retrospectively reviewed 33 patients who underwent two level ACDF with anterior plating using allogenous bone graft from January 2013 to June 2017. Various factors related to cervical sagittal alignment were measured preoperatively (PRE), postoperatively (POST), and last follow-up. The collapse was defined as the ratio of decrement from POST disc height to follow-up disc height. We also defined significant collapses as disc heights that were decreased by 30% or more after surgery. The intraoperative distraction was defined as the ratio of increment from PRE disc height to POST disc height. Results : The subsidence rate was 4.5% and graft collapse rate was 28.8%. The pseudarthrosis rate was 16.7% and there was no association between pseudarthrosis and graft collapse. Among the collapse-related risk factors, pre-operative segmental angle (p=0.047) and intra-operative distraction (p=0.003) were significantly related to allograft collapse. The cut-off value of intraoperative distraction ${\geq}37.3%$ was significantly associated with collapse (p=0.009; odds ratio, 4.622; 95% confidence interval, 1.470-14.531). The average time of events were as follows: collapse, $5.8{\pm}5.7months$; subsidence, $0.99{\pm}0.50months$; and instrument failure, $9.13{\pm}0.50months$. Conclusion : We experienced a higher frequency rate of collapse than subsidence in ACDF using an allograft. Of the various preoperative factors, intra-operative distraction was the most predictable factor of the allograft collapse. This was especially true when the intraoperative distraction was more than 37%, in which case the occurrence of graft collapse increased 4.6 times. We also found that instrument failure occurs only after the allograft collapse.