• 제목/요약/키워드: practical tracing

검색결과 55건 처리시간 0.021초

환경 친화적 스마트 아웃도어 재킷제작 및 사용성 평가 (Eco-friendly Smart Outdoor Jacket Production and Usability Evaluation)

  • 이정란
    • 한국의류학회지
    • /
    • 제38권6호
    • /
    • pp.845-856
    • /
    • 2014
  • This study focused on the production and usability evaluation of smart outdoor jackets that are designed to provide convenience to middle-aged people by embedding devices for lighting and location tracing. The results were as follows. 1. Jacket power supplier was a assembled system composed of battery, charger, controller and switch. A solar cell was attached on the upper arm, and a wire type EL on the center line of a raglan sleeve along with a GPS on the left sleeve with a transparent vinyl pocket. The total weight of the jacket embedded with devices was 385-520g. 2. Operation of function, activity, acceptability, safety, convenience for device use, appearance, practical maintenance were selected based on an analysis of evaluation criteria of previous smart wear research. Criteria were narrowed to three major categories of satisfaction, appearance and maintenance. 3. Use satisfaction criterion consisted of wearable device functionality and physical, psychological use convenience. The evaluation indicated actual functionality. EL functions were especially effective and necessary. Convenience of use showed that a smart jacket was thought to be safe and the size was moderate regardless of age and gender. Outer appearance was satisfactory and respondents praised the color. The practical maintenance evaluation indicated that there was no challenge in doing the laundry since the solar battery and GPS were detachable. The practical use of smart outdoor jackets confirmed by fabric that was washable and dried quickly.

생산자동화시스템 PLC 제어프로그램의 안전성 정형검증에 관한 연구 (Formal Verification of PLC Program Safety in Manufacturing Automation System)

  • 박창목
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.179-192
    • /
    • 2015
  • In an automated industry PLC plays a central role to control the automation system. Therefore, fault free operation of PLC controlled automation system is essential in order to maximize a firm's productivity. A prior test of control system is a practical way to check fault operations, but it is a time consuming job and can not check all possible fault operation. A formal verification of PLC program could be a best way to check all possible fault situation. Tracing the history of the study on formal verification, we found three problems, the first is that a formal representation of PLC control system is incomplete, the second is a state explosion problem and the third is that the verification result is difficult to use for the correction of control program. In this paper, we propose a transformation method to reproduce the control system correctly in formal model and efficient procedure to verify and correct the control program using verification result. To demonstrate the proposed method, we provided a suitable case study of an automation system.

73/78 해양오염방지협약의 개정동향과 개요 (A Study on the Recent Amendment relating to the International Convention for the Prevention of Pollution from Ship, 1973/1978)

  • 황석갑
    • 한국항해학회지
    • /
    • 제17권2호
    • /
    • pp.29-56
    • /
    • 1993
  • The International Convention for the Prevention of Pollution from Ship, 1973, as modified by the Proto-col of 1978 relating thereto, well known as MARPOL 73/78, is probably the most important international agreement on the subject of marine pollution. The main purpose of the Convention is to reduce the total oil remaining on board vessel to minimum. MARPOL is a combination of different sets of rules on oil, chemicals, noxious substances in package forms, sewage and garbage as shown on each Annex. Since the Convention has globally set forth in 1973, it has amended so often whenever reasonable articles are requi-red by contracting states under guidelines of IMO. The amendments, for instance, have continuously perfo-rmed more than 8 times regarding articles, protocols, and five annexes because the original text was badly drafted as the control measures were expressed in general way. This paper, therefore, is intend to summa-rize a main point relating to each amendment, so that persons who have an interest in the Convention would be completely understand for practical implementation. Especially, for legislative purpose or annen-dement of domestic law, it could timely be contributable if specific consolidation and unified interpretations are followed with this paper. Consequently it is much more worth to study for preventing marine pollution from ship with tracing every moment whenever the Convention formally adopted through amending up-to-data.

  • PDF

An Efficient Dynamic Group Signature with Non-frameability

  • Xie, Run;Xu, Chunxiang;He, Chanlian;Zhang, Xiaojun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권5호
    • /
    • pp.2407-2426
    • /
    • 2016
  • A group signature scheme allows any member to sign on behalf of a group. It is applied to practical distributed security communication environments, such as privacy-preserving, data mining. In particular, the excellent features of group signatures, including membership joining and revocation, anonymity, traceability, non-frameability and controllable linkability, make group signature scheme more attractive. Among these features, non-frameability can guarantee that a member's signature cannot be forged by any other (including issuer), and controllable linkability supports to confirm whether or not two group signatures are created by the same signer while preserving anonymity. Until now, only Hwang et al.'s group schemes (proposed in 2013 and 2015) can support all of these features. In this paper, we present a new dynamic group signature scheme which can achieve all of the above excellent features. Compared with their schemes, our scheme has the following advantages. Firstly, our scheme achieves more efficient membership revocation, signing and verifying. The cost of update key in our scheme is two-thirds of them. Secondly, the tracing algorithm is simpler, since the signer can be determined without the judging step. Furthermore, in our scheme, the size of group public key and member's private key are shorter. Lastly, we also prove security features of our scheme, such as anonymity, traceability, non-frameability, under a random oracle model.

복사열 반사판의 설계를 위한 광학적 해석 및 실험기법 (Optical Analysis and Experimental Method for Design of Radiative Thermal Reflector)

  • 정해용;송태호;유승열
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.563-569
    • /
    • 2008
  • Radiative, heating is suitable for outdoor heating system in windy and cold seasons. Optimal design of the reflector is very important to maximize heat transfer to a specific target area in the open space. The geometrical optical theory can be applied to analyze efficiency of the reflector. Commercial ray tracing computer programs are available only for limited geometries of the reflector. Alternatively, it may be designed and analyzed through an approximated simple lens theory. Two types of reflectors are analyzed using either of these methods. The key issue in this paper is to propose a new illumination experimental method for determination of the radiative efficiency. Optical light source and illuminometer are employed. The calculated efficiency of the reflector is compared with experimental one for checking the reliability. The relative errors between the experimental and analytical results are less than 5%, which proves the validity of this method. Based on these methodologies, a practical reflector and heating lamp unit is developed.

Assessment of Total Transfer Capability Using IPLAN: An Application of UPFC for Total Transfer Capability Enhancement

  • Lee Byung Ha;Kim Jung-Hoon;Kwak No-Hong;Lee Woon-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.244-251
    • /
    • 2005
  • Power transfer capability has been recently highlighted as a key issue in many utilities. It is determined by the thermal stability, dynamic stability and voltage stability limits of generation and transmission systems. In particular, voltage stability affects power transfer capability to a great extent in many power systems. This paper presents a tool for determining total transfer capability from a static voltage stability viewpoint using IPLAN, which is a high level language used with the PSS/E program. The tool was developed so as to analyze static voltage stability and to determine the total transfer capability between different areas from a static voltage stability viewpoint by tracing stationary behaviors of power systems. A unified power flow controller (UPFC) is applied for enhancing total transfer capability between different areas from the viewpoint of static voltage stability. Evaluation of the total transfer capability of a practical KEPCO power system is performed from the point of view of static voltage stability, and the effect of enhancing the total transfer capability by UPFC is analyzed.

Current methodologies in construction of plant-pollinator network with emphasize on the application of DNA metabarcoding approach

  • Namin, Saeed Mohamadzade;Son, Minwoong;Jung, Chuleui
    • Journal of Ecology and Environment
    • /
    • 제46권2호
    • /
    • pp.126-135
    • /
    • 2022
  • Background: Pollinators are important ecological elements due to their role in the maintenance of ecosystem health, wild plant reproduction, crop production and food security. The pollinator-plant interaction supports the preservation of plant and animal populations and it also improves the yield in pollination dependent crops. Having knowledge about the plant-pollinator interaction is necessary for development of pesticide risk assessment of pollinators and conservation of endangering species. Results: Traditional methods to discover the relatedness of insects and plants are based on tracing the visiting pollinators by field observations as well as palynology. These methods are time-consuming and needs expert taxonomists to identify different groups of pollinators such as insects or identify flowering plants through palynology. With pace of technology, using molecular methods become popular in identification and classification of organisms. DNA metabarcoding, which is the combination of DNA barcoding and high throughput sequencing, can be applied as an alternative method in identification of mixed origin environmental samples such as pollen loads attached to the body of insects and has been used in DNA-based discovery of plant-pollinator relationship. Conclusions: DNA metabarcoding is practical for plant-pollinator studies, however, lack of reference sequence in online databases, taxonomic resolution, universality of primers are the most crucial limitations. Using multiple molecular markers is preferable due to the limitations of developed universal primers, which improves taxa richness and taxonomic resolution of the studied community.

말기신부전 환자의 혈액투석 치료가 안면 색에 미치는 영향 (The Influence of Hemosialysis to the Face Color of Patients in End Stage Renal Disease)

  • 이세환;조동욱
    • 정보처리학회논문지B
    • /
    • 제17B권6호
    • /
    • pp.437-444
    • /
    • 2010
  • 본 논문에서는 한의학의 진단법인 사진법 중 망진(望診)이론을 기반으로 인체 오장 중 가장 중요한 장기의 하나인 신장의 질환 진단을 위해 영상처리기법을 적용하여 색과 신장 질환과의 상관성을 분석하는 방법을 제안하고자 한다. 이를 위해 안면 영상을 처리하고 분석하여 신장 질환에 따른 얼굴색의 색차를 시각화, 객관화하기 위한 방법을 제시하고자 한다. 특히 본 논문은 신장질환자 중 만성신부전으로 인해 혈액 투석 치료 중인 신장 기능 이상자 들을 대상으로 피 실험자 집단군을 구성하고 안면 영상 및 임상 자료를 수집하여 한의학적 망진 이론에서 신장과 관련된 얼굴 부위가 지각 이며 신장에 이상이 생길 경우 이 부위를 통해 흑색이 발현한다는 이론을 가설로 제시하고 안면 영상 중 지각 부위를 추출하는 알고리즘과 이 부위의 흑색의 변화를 측정 하는 방법에 대해 제안하고자 한다. 끝으로 임상 실험 및 자료 분석을 통해 제안한 방법의 유용성을 입증하고자 한다.

해군 함정 내부공간에 대한 2.4GHz 대역의 채널 특성과 경로손실모델 분석 (Analysis of Path Loss Model and Channel Characteristics at 2.40Hz on Navy Warship's Internal Space)

  • 최대근;이정규;김영훈;김성철
    • 한국통신학회논문지
    • /
    • 제36권11B호
    • /
    • pp.1422-1432
    • /
    • 2011
  • 무선 네트워크가 요즘 들어 기술적인 도약을 이루면서 그 적용범위나 역할이 중요해지고 있다. 국방 분야에서도 무선 네트워크를 도입하여 유선의 한계를 극복하고 개선하려는 움직임도 적지 않으며 특히 현재 해군 함정 내부에서의 대부분의 통신을 유선을 이용하기 때문에 복잡하고 비효율적이다. 본 논문에서는 함정 내 무선 네트워크 구축을 위해서 일반적인 실내 전파환경과는 많은 차이점을 가지는 함정 내 격실 및 복도에 대해 전파 환경 측정실험을 실시하고 모델링을 하였다. 함체 전체가 철 구조물로 이뤄진 특수 환경인 함정 내에서 2.4GHz 대역의 주파수에 대한 CW 측정을 통해 전파환경 특성을 분석하고 함정 내부공간에 대한 전파 경로 손실 모델을 제시하며, 전파 추적 시뮬레이션 기법을 통해 측정 결과와 비교 분석하였다. 더욱이, 기존에 연구되었던 실내 전파환경에 대한 전파 경로손실 모텔과 비교 분석하여 차이점을 도출하여 함정 내 무선 네트워크의 활용방안에 대해 고찰하였다.

발전보일러의 최적연소조정에 대한 실험적 연구 (The Study of Optimized Combustion Tuning for Fossil Power Plant)

  • 정재진;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.102-108
    • /
    • 2009
  • Fossil power plants firing lower grade coals or equipped with modified system for NOx controls are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. In order to develop a on-line combustion tuning system, field test was conducted at operating power boiler. During the field test the exhaust gases' $O_2$, NOx and CO was monitored by using a spatially distributed monitoring grid located in the boiler's high temperature vestibule and upper convective back-pass region. At these locations, the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. using these monitored information we can improving combustion at every point within the furnace, therefore the boiler can operate at reduced excess $O_2$ and gas temperature deviation, reduced furnace exit gas temperature levels while also reducing localized hot spots, corrosive gas conditions, slag or clinker formation and UBC. Benefits include improving efficiency, reducing NOx emissions, increasing output and maximizing availability. Discussion concerning the reduction of greenhouse gases is prevalent in the world. When taking a practical approach to addressing this problem, the best way and short-term solution to reduce greenhouse gases on coal-fired power plants is to improve efficiency. From this point of view the real time optimized combustion tuning approach is the most effective and implemented with minimal cost.

  • PDF