• Title/Summary/Keyword: power-on rising time

Search Result 106, Processing Time 0.026 seconds

Proposal of Practical Reference-Model and It's Performance Improvement for PID Control (PID제어를 위한 실용적인 기준 모델 제안과 성능개선)

  • Hur, J.G.;Yang, K.U.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.66-72
    • /
    • 2007
  • This study proposed new method to decide the reference model necessary for design PID controller. In generally, control design problems using the reference model have the following two factors. One factor is that numerical model of the controlled system can be obtained extremely, and the other is that specification for the closed-loop dynamic performance is pure moderate. Therefore, the control design procedure is essentially based on the partial reference model matching which offers a reasonable method to simplify the design and the controller configuration under the controlled system uncertainty. ITAE(Integral of time-multiplied absolute error) performance index and Kitamori method etc. which were used a reference model method had a limit to settling time and rising time of reference model that it arrived to steady state response according to the controlled system. On this study, if it only knew peak time of overshoot and settling time by measurement signal of the controlled system, it can be made the reference model easily. We proposed new method to improve performance index of the reference model superior to existing reference model index and illustrate the numerical simulation results to show the effectiveness of proposed control method design.

  • PDF

Effect of Operational Parameters on the Removal of Microcystis aeruginosa in Electro-flotation Process

  • Lucero, Arpon Jr;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1417-1426
    • /
    • 2016
  • Despite the low removal efficiencies reported by previous studies, electro-flotation still stands out among other microalgae removal methods for its economical and environmental benefits. To enhance removal efficiency, the important factors that limit the performance of this method must be investigated. In this study, the possible ways of increasing the removal efficiency of microalgae have been explored by investigating the effects of several important variables in electro-flotation. Eight parameters, namely flotation time, rising time, current density, pH, conductivity, electrode distance, temperature and initial concentration were evaluated using a one-parameter-at-a-time approach. Results revealed that the operational parameters that greatly affected the removal efficiency of microalgae were electro-flotation time, current density, pH, and initial concentration. The effect of conductivity, electrode distance, and temperature on removal efficiency were insignificant. However, they exhibited positive an indirect positive effect on power demand, which is nowadays considered an equally important aspect in the running of a feasible and economically efficient electro-flotation process.

A Study on the Improvement of ripple factor tube voltage waveforms in inverter type X-ray generator (인버터식 X선장치의 관전압 맥동율 개선에 관한 연구)

  • 이성길;임홍우;조금배;정수복;백형래
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.234-238
    • /
    • 1999
  • In order to radiate X-ray, the low ripple stabilized high voltage DC over the range of 40KV to 150KV is directly inflicted to X-ray tube. The energy characteristics of the radiated X-ray depend on the pulsating waveforms of the DC voltage supplied X-ray tube. In general, the low ripple voltage waveforms with fast rising times are required to increase with the dosage per unit time lest the exposure time should be longer in orde that the motion artifacts of an object may be eliminated in actual. The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing new power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple, a high frequency PWM inverter is connected between DC source and high voltage transformer. This paper describes the output characteristics according to stabilize ripple of X-ray tube voltage and compared the reproducibility, direcibility and doesage.

  • PDF

A Study on High Frequency Resonant Type X-ray Generator (고주파 공진형 방식 X-선 발생장치에 관한 연구)

  • Yoo, Dong-Wook;Ha, Sung-Woon;Baek, Joo-Won;Kim, Jong-Soo;Kim, Hack-Seong;Won, Chung-Yuen
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.209-211
    • /
    • 1995
  • This paper is concerned with High Frequency, High Voltage Generator for X-ray using zero-voltage soft-switching PWM DC-DC high-power converter by Resonant method, which makes the most of the parastic LC parameters of high-voltage transformer link, for diagnostic X-ray power generator. The converter circuit basically utilizes phase-shift pulse width modulated series Resonant full-bridge PWM DC-DC high-power converter operating at a constant frequency;25kHz. The converter output regulation is digitally controlled using DSP (Digital Signal Processor) for obtaining a fast rising time and adjust output voltage within a wide load range.

  • PDF

Design and analysis of disk bump to Improve unloading performance (언로드 성능향상을 위한 디스크 범프의 디자인 및 해석)

  • Lee, Hyung-Jun;Lee, Yong-Hyun;Kim, Ki-Hoon;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.140-143
    • /
    • 2006
  • Load/Unload(L/UL) technology includes the benefits, that is, increased areal density, reduced power consumption and improved shock resistance. The main issues of L/UL are no slider-disk contact and no media damage. To make sure L/UL stability, we consider many design parameters in L/UL systems. This paper is focused on disk design parameters through designing a disk bump in outer guard band(OGB). In the case of bump design on the disk, we create a bump by changing bump design parameters as like size and amplitude. From dynamic analysis, we choose optimal bump model with the highest flying height and the longest rising time. When a slider passes over a bump in dynamic system, the slider rise above bump according to bump shape. On the basis of this rising effect on the bump, we apply bump design to classical L/UL system having slider-disk contact possibility. This study is based on the simulation, we finally realize improved slider unloading performance by applying slider dynamic result on unload simulation.

  • PDF

A Study on Review of the Current Noise Impact Assessment for the Power Plant (발전소 플랜트 소음영향평가 현황 및 민원사례를 통한 개선방향 연구)

  • Choung, Tae-Ryang;Park, Young-Min;Son, Jin-Hee;Cho, Man-Hee;Hong, Woong-Ki;Song, Jeong-Un
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.941-949
    • /
    • 2012
  • The various plants including power plants have been increased near downtown in accordance with the policy objective of rising the power feed rate and development projects. As a result of these various plants near residential area, noise damage complaints has been raised very often. The power plant is included with the range of environmental impact assessment project. Nevertheless, environmental noise issues regarding construction of these power plants have arisen. Accordingly it is time to consider the environmental and social issues of plants noise in accordance with the government's policy objectives of increased power production. In this study, we reviewed the current noise impact assessment and we also sought solutions to these issues. In order to minimize the problem of noise impact on neighborhood and residents, we intended to propose alternative method of 3D simulation in dealing with these issues.

A Study on Operating Characteristics of the CO2 Laser with Inductively Pulsed Power System (유도형(誘導型) Pulsed Power 전원을 이용한 CO2 레이저 동작 특성에 관한 연구)

  • Kim, Geun-Yong;Min, Byoung-Dae;Kim, Yong-Cheol;Lee, Yu-Soo;Chung, Hyun-Ju;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1710-1713
    • /
    • 2002
  • Recently, the pulsed power system has been used to many applications. Such as remediation of environmental hazards, food sterilization, air pollution control E/P (Electrostatic Precipitator), DeNOx/DeSOx power system, ozone generator, high energy physics, and other power source applications. A pulse energy efficiency for load depends on the rising time, peak value. Pulse duration and impedance matching etc. The pulsed power system generally required for short pulse duration and high peak value was forced to consider its volume and economy. In this paper, we investigated operating characteristics of the CO2 laser using an inductively pulsed power system.

  • PDF

A New High Speed Pulsed Mode Switching DC Power Supply with High Power Factor (새로운 방식의 고속 펄스모드 스위칭 기능을 갖는 고역률 직류전원장치)

  • 안종수;노의철;김인동
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.1
    • /
    • pp.47-54
    • /
    • 2004
  • A new high voltage DC power supply is proposed. The proposed power supply is constructed with several power converters connected in series. It is easy to obtain high DC voltage for the same structure of each power converter. The output DC power of the proposed power supply can be disconnected from the load within several hundred microseconds at the instant of a load short-circuit fault. The rising time of the output DC voltage is also as small as several hundred microseconds, and there is no overshoot of the voltage because all of the output filter capacitors keep undischarged state even in load short-circuit condition. Therefore, the proposed scheme is suitable for the protection of frequent output short-circuit and fast on/off switching of output DC voltage. The proposed power supply has improved features such as simple structure, high power factor, and reduced size and volume compared with the conventional schemes. The operating principle is described and the validity of the proposed scheme is proved through simulations and experiments.

Error Correction Technique of Distance Measurement for ToF LIDAR Sensor

  • Moon, Yeon-Kug;Shim, Young Bo;Song, Hyoung-Kyu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.2
    • /
    • pp.960-973
    • /
    • 2018
  • This paper presents design for error correcting algorithm of the time of flight (ToF) detection value in the light detection and ranging (LIDAR) system sensor. The walk error of ToF value is generated by change of the received signal power depending on distance between the LIDAR sensor and object. The proposed method efficiently compensates the ToF value error by the independent ToF value calculation from the received signal using both rising point and falling point. A constant error of ~0.05 m is obtained after the walk error correction while an increasing error up to ~1 m is obtained with conventional method.

The Study on the Mutual Characteristics Between Transmitting Efficiency of Pulse Energy and Wall Plug Consumed Power of Non-Thermal Plasma (저온 플라즈마의 펄스에너지 전송효율과 Wall Plug 소비전력과의 상호 특성에 관한 연구)

  • Jeong, Jong-Han;Jeong, Hyeon-Ju;Kim, Hwi-Yeong;Jeong, Yong-Ho;Song, Geum-Yeong;Kim, Geun-Yong;Kim, Hui-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.506-510
    • /
    • 2002
  • In this paper, we study on the mutual characteristics between transmitting efficiency of pulse energy and wall plug consumed power of non-thermal Plasma for removing environmental pollutive gas of coal plant. To obtain high pulse energy of our system, we used MPC(magnetic pulse compressor) of power switch and tested their characteristics by adjusting electrode length of reactor and charging voltage in capacitor. As a result, we obtained consumed power of wall plug and a compressed pulse of voltage 110kV, rising time 500ns. Impedance of load on increasing electrode length was decreased, but electrical efficiency was increased. These results indicate we can control critical voltage of pulse corona and electrical efficiency of economic cost in power plant.