• 제목/요약/키워드: power transmission

검색결과 5,796건 처리시간 0.034초

전기유변성 클러치의 동력전달 메커니즘 제3보 : ER 클러치 성능에 관한 실험적 고찰 (Power Transmission Mechanism of Electrorheological Clutch Part III: Experimental considerations on performance of ER clutch)

  • 이규한;심현해;김창호;임윤철
    • Tribology and Lubricants
    • /
    • 제13권4호
    • /
    • pp.1-9
    • /
    • 1997
  • ER clutch is a device using ER fluid, so called "intelligent material" and is a power transmission system controlled with electric field strength. In this paper(Part III), the behavior of ER clutch under proper conditions was investigated experimentally and compared to theoretical analyses developed from Part I, II. Considering the optimum design concept proposed from Part I, the concentric cylinder type of ER clutch was designed and the experimental apparatus for the performance test was constructed. The comparisons made indicated that the power transmission model of ER clutch and the temperature rise model of ER fluid developed from Part I, II were acceptable for engineering design calculations.culations.

Design and tests of prototype HTS power transmission cables

  • 하홍수;조영식;오상수;성기철;권영길;류강식;조전욱
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.280-284
    • /
    • 2000
  • The prototype high-T$_c$ superconducting (HTS) power transmission cables have been designed and fabricated multi layers of spirally wound HTS tapes. The cables were made Bi-2223 based Ag-sheathed HTS tapes, and tested in LN$_2$. Critical currents of 700A dc and better were achieved. The magnetic flux density and field direction were analyzed in the cable configuration. In this paper the results of analysis and tests of HTS power transmission cables were described.

  • PDF

저압배선의 이상 진단을 위한 시간-주파수영역 반사파계측 방법의 기준신호 설계기법 연구 (Reference Signal Design of TFDR for Low Voltage Power Transmission Line)

  • 이춘구;곽기석;박진배;윤태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1543-1544
    • /
    • 2008
  • In this paper, we introduce a gaussian enveloped linear chirp signal that can change parameters for consideration of target material characteristics. Using the gaussian enveloped linear chirp signal, time-frequency domain reflectomety is able to detect fault location in power transmission line. we suggest design method of reference signal for power transmission line fault detection. This method is verified by locating fault in HIV low voltage power transmission line.

  • PDF

광역정전 복구를 위한 시송전 계통 분석시스템 개발 (Development of the Primary Restorative Transmission System Analyser to Restore Massive Blackout)

  • 이남호;송인준;김경호;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.161-163
    • /
    • 2002
  • Service restoration following a complete or partial collapse starts with reenergizing a transmission line from black-start generators. Voltage problems can arise from Ferranti effect as unloaded transmission line is reenergized. This Paper presents system analyser to develop for verifying the primary restorative transmission system. The algorithm which has been used in the analyser is to handle load pick-up compensating Ferranti effect. and terminal voltage and reactive capability limitation of black-start generators about self-excitation.

  • PDF

계통계획기준 수립을 위한 한전계통의 성능평가 (Performance Evaluation of Korean Power System for Developing the Planning Standards)

  • 국경수;오태규;김태현;김학만;방민재;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.203-205
    • /
    • 2001
  • This paper is part of an ongoing project of KEPCO; 'A Study on Criteria and Standards for Transmission System Planning', The objective of this project is to develop the standards and procedures for transmission system planning. This involves reviewing published literatures, other documents of existing criteria and procedures, and various case studies of advanced countries which are already under the competitive electricity industry. This paper presents the result of evaluating Korean Power System as a pre-study for developing the Planning Standards of Korean Power System. For this, WSCC/NERC's performance criteria for planning transmission system, and KEPCO's 'Long Term Transmission System Planning Criteria' are considered. By doing this, the level of performance criteria which should be applied to Korean Power System and the detailed procedures which would be used in system test were reviewed.

  • PDF

5.8GHz 마이크로파 무선전력전송을 위한 수신기 모듈 설계 및 구현 (Design and Fabrication of a Receiver Module for 5.8GHz Microwave Wireless Power Transmission)

  • 이성훈;손명식
    • 반도체디스플레이기술학회지
    • /
    • 제15권4호
    • /
    • pp.16-21
    • /
    • 2016
  • In this paper, we have designed and fabricated a receiver module for 5.8GHz Microwave Wireless Power Transmission. The receiver module was composed of an antenna, BPF (Band Pass Filter) and RF-DC converter. The antenna was designed to RHCP (Right Hand Circular Polarization). And we used ${\lambda}g/2$ open-circuited stubs for the BPF. In addition, the RF-DC converter used the tripler voltage circuit for voltage multipliers. The integrated receiver RF module for 5.8GHz Microwave Wireless Power Transmission has been designed and fabricated. The voltage was measured to the distance of 50cm.

Computationally Efficient 2-D DOA Estimation Using Two Parallel Uniform Linear Arrays

  • Cao, Hailin;Yang, Lisheng;Tan, Xiaoheng;Yang, Shizhong
    • ETRI Journal
    • /
    • 제31권6호
    • /
    • pp.806-808
    • /
    • 2009
  • A new computationally efficient algorithm-based propagator method for two-dimensional (2-D) direction-of-arrival (DOA) estimation is proposed, which uses two parallel uniform linear arrays. The algorithm takes advantage of the special structure of the array which enables 2-D DOA estimation without pair matching. Simulation results show that the proposed algorithm achieves very accurate estimation at a computational cost 4 dB lower than that of standard methods.

Design of a Novel Multi-Dimensional HCOC Multi-code Spread Spectrum System Using Pre-coding Technique for High Speed Data Transmission of DS-CDMA

  • Kong, Hyung-Yun;Lee, Dong-Un
    • Journal of electromagnetic engineering and science
    • /
    • 제7권1호
    • /
    • pp.1-6
    • /
    • 2007
  • Recently, Mc(Multi-code) modulation/demodulation(modem) technique has been explored for high speed data transmission in wireless environment. The conventional Mc modem generates some side effects such as allocating Walsh codes, which motivates to propose a novel Mc modem method with sub-code. Our proposed system should expanded the size of sub-code to provide high-rate data transmission, which also affect adversely to the performance of the system with high PAPR(Peak to Average Power Ratio). Thus, in this paper, we propose a novel pre-coded Multi-Dimensional HCOC(High Capacity Orthogonal Code) Mc modem technique to reduce the high PAPR, which enables the performance improvement. This proposed system can be easily designed by concatenating HCOC Mc modem with the generic Mc modem. The pre-coding technique that is used in this paper is CAC(Constant Amplitude Coding), that helps the system maintain the constant transmission power and reduce the maximum transmission power.

154kV 송전선로용 피뢰기 현장 설치 효과 분석 (A Study on the Effects of Lightning Arrestors Installment on a 154kV Transmission System)

  • 최한열;구성완;민병욱;박순규;이봉희;곽주식
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.184-189
    • /
    • 2009
  • Lightning has been identified as one of the leading causes of outages on transmission and distribution systems. As sensitive loads and reliance on electric power increase year by year, it is getting more focus on stable and high quality of power supply. To protect the transmission and distribution line from lightning, the transmission lightning arrester can be the effective facility on the power system. This paper discusses Gapped type Arresters application results by analysing effects of lightning arresters on transmission and distribution line.

바이트반전 전송방식을 이용한 플리커 방지 가시광통신시스템 (Flicker-Free Visible Light Communication System Using Byte-Inverted Transmission)

  • 이성호
    • 센서학회지
    • /
    • 제26권6호
    • /
    • pp.408-413
    • /
    • 2017
  • In this paper, we newly developed a byte-inverted transmission method for flicker-free visible light communication (VLC). The VLC transmitter sends original data in the former half period of the clock, and inverted data and in the latter half period of the clock. The VLC receiver receives the original data in the in the former half period of the clock. In this system, we used 480Hz clock that was generated from the 60Hz power line. The average optical power of the LED array in the transmitter is constant, thus flicker-free, in the observation time longer than the period of the clock that is about 2ms. This period is shorter than the maximum flickering time period (MFTP) of 5ms that is generally considered to be safe. This configuration is very useful in constructing indoor wireless sensor networks using LED light because it is flicker-free and does not require additional transmission channel for clock transmission.