• 제목/요약/키워드: power to gas

검색결과 4,291건 처리시간 0.033초

병원건물 분산에너지시스템 도입에 따른 경제성분석 (The Basic Study on Economic Evaluation of Distributed Energy System Installed in Hospital)

  • 홍원표;김병수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1136_1138
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that burn gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

병원건물의 마이크로터빈과 신재생에너지도입에 따른 경제성평가 기초연구 (The Basic Study on Economic Evaluation of Micro-turbine and Alternative Energy system Installed in Hospital)

  • 김병수;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.439-444
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of. solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that bum gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

100 MW급 Power-to-Gas 시스템의 사전 경제성 분석 (The Economic Feasibility Analysis of 100-MW Power-to-Gas System)

  • 고아름;박성호;김수현
    • 청정기술
    • /
    • 제26권1호
    • /
    • pp.55-64
    • /
    • 2020
  • 재생에너지 3020 이행계획에 따라 재생에너지 발전 비중 증가에 대비해 잉여전력 저장 및 전력 공급 안정화 기술 필요성이 대두되고 있다. 이를 위해 수요 공급의 불균형으로 활용할 수 없는 전력을 수소 또는 메탄으로 전환하여 저장하는 Power-to-Gas 기술 개발이 활발히 진행되고 있다. 본 연구에서는 국내 실정을 반영한 Power-to-Gas 경제성분석을 수행하였다. 균등화 수소원가를 산정하기 위하여 Total revenue requirement 방법론을 활용하여 경제성 분석 방법론을 재정립하고, 국제에너지기구의 경제성 분석 결과를 통해 검증하였다. 연구결과 국내 기준 100 MW급 Power-to-Gas 시스템 균등화 수소원가는 kg당 8,344원으로 나타났다. 전기 비용, 수전해 장비 비용, 작동 연한에 따른 민감도 분석이 수행되었고, 재생에너지 이용 수소 생산비용과 천연가스 개질 수소 생산비용을 비교하여 경제성을 확보할 수 있는 조건을 제시하였다.

소형 가스엔진 열병합 발전시스템 안전기준 개발 (A Study on the Safety Code Development of Gas Engine Micro Combined Heat and Power System)

  • 권준엽;김민우;이정운
    • 한국가스학회지
    • /
    • 제25권4호
    • /
    • pp.27-35
    • /
    • 2021
  • 최근 "전력 예비율" 급감에 대한 해결책으로 양방향 송배전이 가능한 마이크로 그리드로 전환되고 있다. 마이크로 그리드는 소규모 분산전원과 부하로 구성되는데, 분산전원의 대표적인 기술로 가정·건물에 적용하는 소형 열병합 발전시스템이 있다. 본 연구에서 가스 소비량 232.6kW(20만 kcal/h) 이내의 소형 가스엔진 발전시스템의 안전기준을 도출하고 발전 시스템, 냉각시스템, 윤활 시스템, 배기 시스템으로 구분하여 안전기준(안)을 개발하였다. 발전시스템의 경우 필터를 설치하고 가스 누출 및 엔진 회전수나 출력에 이상이 발생할 경우 이를 감지하여 시스템이 정지하도록 하였고, 냉각시스템은 냉각수 부족이나 과열이 발생할 경우 시스템이 정지하도록 규정하였다. 윤활 시스템은 윤활유의 압력과 온도를 모니터링 하고 이상이 발생할 경우 시스템을 정지하도록 하고, 배기 시스템은 국내·외 기준과 부합하여 배기가스 배출 농도 규제 값을 지정하였다. 본 연구 결과를 통해 가스엔진 발전시스템의 안전성을 향상시키고 제품 확산·보급에 이바지할 수 있다고 판단한다.

펄스전원에 의한 수산화가스 발생기에 관한 연구 (A Study on Analysis of the Hydrogen-Oxygen Gas Generator Using Pulse Power Supply)

  • 이정민;강병희;목형수;최규하
    • 전력전자학회논문지
    • /
    • 제6권5호
    • /
    • pp.377-385
    • /
    • 2001
  • 물을 전기분해하여 얻은 일정 부피비를 갖는 수소와 산소 혼합가스를 수산화가스로 명명하며, 이를 역반응시켜서 열 에너지원으로 사용하고 있다. 수산화가스는 경제성, 안전성 및 환경친화적인 고유한 특성을 지니고 있어서 현재 가스용접기에 적용하고 있으며 여러 가지 응용분야에 적용할 수 있도록 연구 중에 있다. 본 논문에서는 수산화가스의 특성에 관하여 고찰하고 발생기용 전원에 대하여 소개하고 이 중에서 아직까지 적용되지 않은 펄스전원을 적용하여 여러 가지 운전주파수에서 비교분석 하였다.

  • PDF

합성천연가스의 수소함량 변화에 따른 가스터빈 연소특성 평가 (Effects of Hydrogen in SNG on Gas Turbine Combustion Characteristics)

  • 박세익;김의식;정재화;홍진표;김성철;차동진
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.412-419
    • /
    • 2012
  • Increasing demand for natural gas and higher natural gas prices in the recent decades have led many people to pursue unconventional methods of natural gas production. POSCO-Gwangyang synthetic natural gas (SNG) project was launched in 2010. As the market price of natural gas goes up, the increase of its price gets more sensitive due to the high cost of transportation and liquefaction. This project can make the SNG economically viable. In parallel with this project, KEPCO (Korea Electric Power Corporation) joined in launching the SNG Quality Standard Bureau along with KOGAS (Korea Gas Corporation), POSCO and so on. KEPCO Research Institute is in charge of SNG fueled gas turbine combustion test. In this research, several combustion tests were conducted to find out the effect of hydrogen contents in SNG on gas turbine combustion. The hydrogen in synthetic natural gas did not affect on gas turbine combustion characteristics which are turbine inlet temperature including pattern factor and emission performance. However, flame stable region in ${\Phi}$-Air flow rate map was shifted to the lean condition due to autocatalytic effect of hydrogen.

소형 가스엔진 열병합발전 시스템의 안전관리 방안에 관한 연구 (A Study on the Safety Management Methods of Micro-Gas Engine Combined Heat and Power System)

  • 김소현;김민우;이은경;이정운
    • 한국가스학회지
    • /
    • 제22권6호
    • /
    • pp.76-89
    • /
    • 2018
  • 지속적인 산업 발전에 따른 에너지 수급의 불안정 및 환경오염 문제가 대두됨에 따라 이에 대한 해결 방안의 일환으로 열병합발전 시스템의 보급이 활발해지고 있다. 국내의 경우 가스엔진을 이용한 열병합발전기의 안전성능에 대한 검사기준이 미비하므로 이에 대한 연구가 필요한 실정이다. 본 연구에서는 20 kW급 가스엔진 열병합발전 시스템에 적용 가능한 안전성능 관련 표준화 연구 수행을 위해 열병합발전 시스템의 국내 외 기준에 대한 안전성능 및 구조/재료 평가기준을 분석하였다. 또한, 위험요소 분석 및 HAZOP (Hazard and Operability Studies)을 이용한 위험성평가를 수행하여 가스엔진 열병합발전 시스템의 안전성능 평가(안)을 도출하였으며, 평가항목으로는 안전성능 관련 엔진 시동, 배관 기밀 성능, 살수 및 온도 상승 성능, 연소 성능, 전기 효율, 열효율, 종합 효율, 습도 성능 등이 포함된다. 가스엔진 열병합발전 시스템의 구조 및 재료와 관련하여 가스 및 수배관, 가스 조절 및 차단밸브, 금속 또는 비금속 재료의 내구성, 내열성, 내한성에 대한 평가항목을 도출하였다.

반도체 공정장비 Gas Scrubber의 에너지 모니터링 시스템개발 (Development of an Energy MonItorIng System for Gas Scrubber)

  • 김선만;임익태;안강호
    • 반도체디스플레이기술학회지
    • /
    • 제10권2호
    • /
    • pp.13-17
    • /
    • 2011
  • We have developed a new energy-consuming monitoring system that has made it possible to measure the energy consumption of a gas scrubber, one of semiconductor processing equipments, and installed this system to the gas scrubber under operating at a manufacture site. Using this system, we have measured consumptions of electric power and processing gas consumed at standby to operating mode. In case of the gas scrubber, processing gas flows continuously into it at standby and operating mode. Therefore, if the electric power has been supplied, the processing gas can flows into the device for 24 hours. Moreover, at operating of gas scrubber, the amount of electricity consumption is 5 kWh. At Standby of gas scrubber, it spends 3kwh. It is certain that the energy consumption is greater at operating mode than at standby mode. The carbon emission rates from 24 hour gas scrubber operation are 236 $kgCO_2$/day of $N_2$, 57 $kgCO_2$/day of electric power and 0.001 $kgCO_2$/day of cooling water. Most of carbon is emitted from $N_2$ gas and electric power consumption.

Syngas및 수소를 연료로 사용하는 발전용 가스터빈 성능해석 (Performance Analysis of a Gas Turbine for Power Generation using Syngas as a Fuel)

  • 이종준;차규상;손정락;김동섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3241-3246
    • /
    • 2007
  • Integrated Gasification Combined Cycle (IGCC) power plant converts coal to syngas, which is mainly composed with hydrogen and carbon monoxide, by the gasification process and produces electric power by the gas and steam turbine combined cycle power plant. The purpose of this study is to investigate the influence of the syngas to the performance of a gas turbine in a combined cycle power plant. For this purpose, a commercial gas turbine is selected and its performance characteristics are analyzed with three different fuels, i.e., natural gas ($CH_4$), syngas and hydrogen. It is found that different heating values of those fuels and chemical compositions in their combustion gases are the causes in the different performance characteristics.

  • PDF

저전력 신호 추출 기법이 내장된 가스 센서 시스템 개발 (Development of a Gas Sensor System with Built-in Low-power Signal Extraction Technique)

  • 현장수;김현준
    • 센서학회지
    • /
    • 제32권2호
    • /
    • pp.105-109
    • /
    • 2023
  • In this study, we present a power-efficient driving method for gas sensor systems based on the analysis of input signal characteristics. The analysis of the gas sensor output signal characteristics in the frequency domain shows that most of the signal portions are distributed in a relatively low frequency region when extracting the gas sensor signal, which can lead to further performance improvement of the gas sensor system. Therefore, the proposed gas signal extracting technique changes the operating frequency of the read-out circuit based on the frequency characteristics of the output signal of the gas sensor, resulting in a reduction of power consumption at the whole system level. The proposed sensing technique, which can be applied to a general-purpose commercial gas sensor system, was implemented in a printed circuit board (PCB) to verify its effectiveness at the commercial level.