• Title/Summary/Keyword: power system monitoring

Search Result 1,943, Processing Time 0.028 seconds

Development of Unmanned Remote Monitoring System for MW Class Wind Turbines (대형 풍력터빈을 위한 무인 원격감시시스템 개발)

  • Park, Joon-Young;Kim, Beom-Joo;Lee, Jae-Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.5
    • /
    • pp.412-418
    • /
    • 2011
  • The scale of wind turbines has continuously increased over the last decade. Especially, the rapid growth of the rotor diameter has brought about the increase of the tower height and the load on the rotor blade, as can be seen in the case of a 5MW class wind turbine with 126m rotor diameter. This trend means the increasing possibility of system failure. In addition to that, it is impossible for human operators to stay and manage all the turbines in the case of a large-scale wind farm. For these reasons, the operation and maintenance technology is getting more importance. In this paper, we present an unmanned remote monitoring system for MW class wind turbines and its application to YeungHeung wind test bed.

A Study on the Information Exchange Technique among Electric Power Facilities and Monitoring Systems (전력 설비 감시 시스템들 간의 정보 교환 기법에 관한 연구)

  • Hong, Chang-Ho;Park, Chan-Eom;Lee, Seung-Chul;Hoon, Un-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.453-456
    • /
    • 2006
  • In this paper, we introduce the design and implementation of Information exchange technique among power system facilities and/or their monitoring systems based on Universal Description, Discovery and Integration Service and Simple Object Access Protocol. The rapid progresses in high speed network, 4G web language S/W and embedded H/W enabled faster and easier communications among electric power systems monitoring facilities. However, each facility or system has its own specific protocol like RS-232 and RS-486, which somewhat limits the capability of flexible information exchange among thor In this paper, we try to demonstrate the potential of utilizing the SOAP and UDDI services in exchanging the metadata and possibly high abstraction level informations among electric power facilities and/or their monitoring systems.

  • PDF

A study on field test of diagnostic Monitoring System for Power Transformers (전력용 변압기 예방진단 시스템의 실 계통 적용 연구)

  • Kim, Y.H.;Lee, C.R.;HwangBo, S.W.;Shin, Y.T.;Park, G.C.;Park, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.91-93
    • /
    • 2004
  • This study presents recent trends on the on-line monitoring and diagnostic systems for oil-immersed transformers. Specially, our system on Yeo Su thermal power plant is introduced for high sensitivity and accuracy of ours. It is combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

Low-power wireless communication System for Biosignal transmission (생체신호 무선 송수신을 위한 소형,저전력 통신시스템 개발)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Kim, Kyeong-Seop;Kim, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.370-372
    • /
    • 2005
  • Inconveniences which might arise in transmitting measured biological data based on cable protocols generally are recognized critical points in tele-monitoring environment and also restrict the mobility of the user. a. Especially, activity monitoring which is importantly recognized as a core parameter in ubiquitous healthcare arena and weight management, pervasive and wireless measuring technology is most needed. In this paper, we would like to suggest lower power, miniaturized communication system in order to solve the above problems. The suggested system is powered by small coin-size battery. Also, The suggested system is compared with a blue-tooth module which is generally available in the commercial market. Even though, the suggested system didn't have higher transmission rate, its low power consumption make the suggested system would be feasible in ubiquitous monitoring of biological signals in ubiquitous healthcare arena.

  • PDF

Development of monitoring system of static frequency converter in pumped storage power plant (양수발전소 SFC 감시시스템 개발)

  • Lee, Joo-Hyun;Lim, Ick-Hun;Ryu, Ho-Sun;Sin, Man-Soo;Kim, Bong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.213-215
    • /
    • 2006
  • A static frequency converter(SFC) in a pumped storage power plant is important equipment for converting electric motor kinetic energy into electric Bower. A SFC monitoring system consists of high voltage thyristor firing equipment, fault detection module, data gathering module, real time data processing equipment and man machine Interface system. This paper describes SFC system overview, developed SFC monitoring system configuration including system characteristics. and successful application result to San-Cheong pumped storage power plant.

  • PDF

A Study on Electric Power Monitoring System per Appliance (기기별 전력 모니터링 시스템 개발에 관한 연구)

  • Park, Sung-Wook;Kim, Jong-Shick;Lim, Su-Jin;HwangBo, Sea-Hee;Son, Joon-Ik;Lee, In-Yong;Wang, Bo-Hyeun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.5
    • /
    • pp.638-644
    • /
    • 2010
  • This paper presents ideas of service scenarios for home residents using electric power monitoring system per appliance, the implementation of the monitoring system, and analysis of acquired electric power usage pattern. By acquiring and analyzing electric power usage pattern, home residents can get information of power usage pattern of every legacy (non-Demand Response-ready) appliance. Further they can get pieces of recommendation how to reduce energy consumption, intelligent standby power blocking service, and alarming service to abnormality of appliances. In order to check the feasibility of the ideas, a system that can acquire electric power pattern per appliance is implemented, and electric power pattern of some appliances are stored to a database and it was analyzed to show if auto-identification of a type of a device is possible, which is a basic required function for the scenarios presented.

On-line Temperature Monitoring of the GIS Contacts Based on Infrared Sensing Technology

  • Li, Qingmin;Cong, Haoxi;Xing, Jinyuan;Qi, Bo;Li, Chengrong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1385-1393
    • /
    • 2014
  • Gas insulated switchgear (GIS) is widely used in the power systems, however, the contacts overheating of the inside circuit breaker or disconnector may be a potential cause of developing accidents. As the temperature of the contacts cannot be directly acquired due to existence of the metallic shield, an infrared sensor is adopted to directly measure the temperature of the shield and then the contacts temperature can be indirectly obtained by data fitting, based on which the on-line temperature monitoring technology specifically for GIS contacts based on infrared sensing is proposed in this paper. A real GIS test platform is constructed and experimental studies are carried out to account for the influential factors that affect the accuracy of the infrared temperature measurement. A heat transfer model of the GIS module is also developed, together with experimental studies, the nonlinear temperature relationship among the contacts, the metallic shield and the environment based on a neural network algorithm is established. Finally, an integrated on-line temperature monitoring system for the GIS contacts is developed for on-site applications.

A Power Quality Monitoring System(PQMS) : A Standard of User-Friendly-GUI & Analysis Graphic Representation (전력품질 모니터링 시스템 : User-Friendly-GUI 및 분석 그래프 표준)

  • Kim, Young-Il;Han, Jin-Hee;Yoon, Tai-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.127-130
    • /
    • 2002
  • Recently, with the increasing use of power semiconductors and microprocessors which are very sensitive to little change of power quality and for coping positively with anticipating power quality disputes between power providers and consumers which are possible to occur by of power market being formed, the power quality problem has gained preponderance among the contemporary research areas. To serve these purposes, the integrated system has been researched and developed for power quality analysis and monitoring, which provides speedy and powerful functions by the growth of computer hardware and information technology. But the advent of fast and lower price hardware make little difference in an application on many systems. As a result, the key issues of constructing power quality monitoring system are in the management of data obtained, accurate algorithms, graphic representation and user-friendly-environment for easy and clear analysis results. So, in this paper it will be introduced that the standard of user-friendly-GUI(Graphic User Interface) and analysis graphic representation for intuitive understanding of results from power quality analysis based on consideration of several systems currently being in use.

  • PDF

Development for Life Assessment System for Pipes of Thermal Power Plants

  • Hyun, Jung-Seob;Heo, Jae-Sil;Kim, Doo-Young;Park, Min-Gyu
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.583-588
    • /
    • 2016
  • The high-temperature steam pipes of thermal power plants are subjected to severe conditions such as creep and fatigue due to the power plant frequently being started up and shut down. To prevent critical pipes from serious damage and possible failure, inspection methods such as computational analysis and online piping displacement monitoring have been developed. However, these methods are limited in that they cannot determine the life consumption rate of a critical pipe precisely. Therefore, we set out to develop a life assessment system, based on a three-dimensional piping displacement monitoring system, which is capable of evaluating the life consumption rate of a critical pipe. This system was installed at the "M" thermal power plant in Malaysia, and was shown to operate well in practice. The results of this study are expected to contribute to the increase safety of piping systems by minimizing stress and extending the actual life of critical piping.

Designing of Smart WAMAC Infra Architecture based on Synchro-Phasor (Synchro-Phasor 기반의 Smart WAMAC 인프라 아키텍쳐 설계)

  • Kim, Ji-Young;Woo, Doug-Je;Kim, Sang-Tae;Choi, Mi-Hwa;Kim, Yong-Kwang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1549-1559
    • /
    • 2010
  • Modern power system is operated and managed in closed network environment with treating a great variety of data, and requirement of real time power system data is more increasing. However, it is difficult for operators to fast evaluate the condition of power system using only isolation network system such as SCADA or EMS regarding unexpecting situations occurring. Recent technology achievement in areas of distributed computing, networking high speed communications and digital control as well as the availability of accurate GPS time source are rapidly becoming the enabling factors for the development of a new generation of real time power grid monitoring tools. In this paper, architecture of WAMAC which is the wide area monitoring and control system not only to control but also to monitoring in real time is proposed and the plan of integration interface with legacy system such as EMS for providing power system analysis base data effectively is suggested.