• 제목/요약/키워드: power system computer control

검색결과 1,166건 처리시간 0.025초

스마트 홈에서 Zigbee 기반의 대기전력 제어 연구 (A Study of Standby Power Control Based on Zigbee in Smart Home)

  • 이성준;김도현
    • 한국멀티미디어학회논문지
    • /
    • 제17권7호
    • /
    • pp.879-885
    • /
    • 2014
  • This paper designs and implements the 2 plug type standby power control outlet based on IEEE 802.15.4 using Zigbee and IPv6 network in order to reduce the standby power to the user. The standby power control system is consisted of direct power and standby power plug. Also this system can communicate bidirectionally in wireless because built-in wireless communication modules. One gateway is linked with many standby power control outlet in wireless. Each standby power control outlet executes the operation needed in power control independently. Also each standby power control outlet has its own power can be detected in real time independently of the power can be controlled.

Spectrum Reuse Schemes with Power Control for Device-to-Device Communication in LTE-Advanced Cellular Network

  • Chhorn, Sok;Yoon, Seok-Ho;Seo, Si-O;Kim, Seung-Yeon;Cho, Choong-Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권12호
    • /
    • pp.4819-4834
    • /
    • 2015
  • The spectral efficiency of cellular networks can be improved when proximate users engage in device-to-device (D2D) communications to communicate directly without going through a base station. However, D2D communications that are not properly designed may generate interference with existing cellular networks. In this paper, we study resource allocation and power control to minimize the probability of an outage and maximize the overall network throughput. We investigate three power control-based schemes: the Partial Co-channel based Overlap Resource Power Control (PC.OVER), Fractional Frequency Reuse based Overlap Resource Power Control (FFR.OVER) and Fractional Frequency Reuse based Adaptive Power Control (FFR.APC) and also compare their performance. In PC.OVER, a certain portion of the total bandwidth is dedicated to the D2D. The FFR.OVER and FFR.APC schemes combine the FFR techniques and the power control mechanism. In FFR, the entire frequency band is partitioned into two parts, including a central and edge sub-bands. Macrocell users (mUEs) transmit using uniform power in the inner and outer regions of the cell, and in all three schemes, the D2D receivers (D2DRs) transmit with low power when more than one D2DRs share a resource block (RB) with the macrocells. For PC.OVER and FFR.OVER, the power of the D2DRs is reduced to its minimum, and for the FFR.APC scheme, the transmission power of the D2DRs is iteratively adjusted to satisfy the signal to interference ratio (SIR) threshold. The three schemes exhibit a significant improvement in the overall system capacity as well as in the probability of a user outage when compared to a conventional scheme.

디지털 계전기를 이용한 전력감시 및 분산제어 (Power Monitoring and Distributed Control by Digital Relay)

  • 이성환;박상배;안인석
    • 한국산업융합학회 논문집
    • /
    • 제4권3호
    • /
    • pp.263-266
    • /
    • 2001
  • In this paper, intelligent methods using digital protection relay in power SCADA system is developed in order to protect power systems by means of timely fault detection during operation and control at starting for induction motor which have various load environments and capacities in power systems. The digital protective relay was designed with DSP CPU(TMS320C31) to protect and measure more quickly and precisely. The test result on the basis of KEMC 1120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within ${\pm}5%$. Also, we can control motors at starting according to starting types with simple method as programmable sequence editor. So we can improve the demerits of high cost and much manhour for rework.

  • PDF

Power Control for D2D Communication in the Cellular System: The Impact of Channel Estimation Error

  • Oh, Changyoon
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권8호
    • /
    • pp.51-57
    • /
    • 2018
  • In this paper, we investigate the impact of channel estimation error on the D2D power control algorithm. In the previous work, D2D power control algorithm has been proposed under the assumption that the channel between the transmitter and the corresponding receiver is perfectly estimated. In reality, the channel estimation error is more often the case. The first question is that the power control algorithm designed for perfect channel estimation is still valid under the channel estimation error environment ? The second question is, if it is not valid, what could be the possible remedy for the channel estimation error ? In this paper, to answer the first question, we investigate the impact of the channel estimation error on the power control algorithm. We first review the D2D power control algorithm designed for perfect channel estimation. Then, we model the channel estimation error. Finally, we summarize the main results observed from the analysis of the simulation.

A New Battery Approach to Wind Generation System in Frequency Control Market

  • Nguyen, Minh Y.;Nguyen, Dinh Hung;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.667-674
    • /
    • 2013
  • Wind power producers face many regulation costs in deregulated environment, which remarkably lowers the value of wind power in comparison with conventional sources. One of these costs is associated with the real-time variation of power output and being paid in frequency control market according to the variation band. This paper presents a new approach to coordination of battery energy storage in wind generation system for reducing the payment in frequency control market. The approach depends on the statistic data of wind generation and the prediction of frequency control market price to determine the optimal variation band which is then kept by the real-time charging and discharging of batteries, ultimately the minimum cost of frequency regulation can be obtained. The optimization problem is formulated as trade-off between the decrease in the regulation payment and the increase in the cost of using battery, and vice versus. The approach is applied to a study case and the results of simulation show its effectiveness.

동적 핸드오프와 전력제어를 고려한 적응배열 시스템의 네트워크 시뮬레이션 (System Level Network Simulation of Adaptive Array with Dynamic Handoff and Power Control)

  • Yeong-Jee Chung;Jeffrey H. Reed
    • 한국시뮬레이션학회논문지
    • /
    • 제8권4호
    • /
    • pp.33-51
    • /
    • 1999
  • In this study, the system level network simulation is considered with adaptive array antenna in CDMA mobile communication system. A network simulation framework is implemented based on IS-95A/B system to consider dynamic handoff, system level network behavior, and deploying strategy into the overall CDMA mobile communication network under adaptive array algorithm. Its simulation model, such as vector channel model, adaptive beam forming antenna model, handoff model, and power control model, are described in detail with simulation block. In order to maximize SINR of received signal at antenna, Maximin algorithm is particularly considered, and it is computed at each simulation snap shot with SINR based power control and handoff algorithm. Graphic user interface in this system level network simulator is also implemented to define the simulation environments and to represent simulation results on real mapping system. This paper also shows some features of simulation framework and simulation results.

  • PDF

3-level인버터를 이용한 과변조영역에서의 간접벡터 유도전동기 구동 (Driving the induction motor of indirect vector control using the 3-level inverter in the overmodulation region)

  • 이재문;정헌선;노세진;이은규;염상구;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.403-405
    • /
    • 2007
  • This paper presents the over-modulation strategy and indirect vector control drive of NPC type PWM inverter. NPC inverter has three level phase voltage output.It can perform in high voltage through assembling switching components. It has less harmonics and surge voltage stress at motor terminals than the 2 level inverter in same switching frequency through 3 level voltage. The conventional railway vehicle has used the vector control to MI=0.907 and the slip-frequency control from MI=0.907 to six-step mode. The slip-frequency control has bad motive power and slow torque control response. But vector control has good motive power and can instant torque control. In this paper, output voltage is controlled linearly from linear region to six-step mode by using over-modulation strategy. And NPC inverter is used.

  • PDF

GUI를 이용한 컴퓨터 Power Supply 내장형 UPS 시스템의 개발 (Development of UPS System Embedded in Computer Power Supply Using GUI)

  • 노인배;박지호;황기현;김동완;우정인
    • 전기학회논문지P
    • /
    • 제53권4호
    • /
    • pp.190-194
    • /
    • 2004
  • In this paper, UPS, which is embedded in computer power supply, is developed against the poor utility power system. In the developed system, PIC16C54 is used as the main controller, and UPS system consists of micom control module, power failure detecting module, charging module, power module, synchronous transfer module, and GUI module. Additionally, GUI module consists of battery charging state unit, power operating unit and operating state unit. The effectiveness of the developed system has been verified by the experimental results.

PC기반의 발전소 시뮬레이터용 입출력 제어 시스템의 설계 (Design of Input Output Control System for Power Plant Simulator based on PC)

  • 조지용;곽귀일;이진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2258-2260
    • /
    • 2001
  • 최근 급속한 하드웨어 및 소프트웨어 기술의 발달로 인하여 PC기반의 분산제어 시스템들이 산업계에 모습을 보이고 있다. 발전소 시뮬레이터는 발전소의 모든 운영을 통제하는 중앙제어실과 똑같은 형태 및 동작특성을 갖춘 설비로 운전원들이 정상적 상황은 물론 가상적인 사고상황에서도 긴급 대응할 수 있도록 훈련에 이용되는 모의훈련 시스템이다. 본 논문에서는 제어 자동화 통신망으로 떠오르고 있는 필드버스와 함께 시뮬레이터 판넬에 설치된 수만개에 달하는 각종 입출력 신호들을 분산된 PC 시스템에서 수집하고 이 신호들을 실시간 통신기술을 이용하여 원격의 현장(시뮬레이션 컴퓨터)까지 송수신해 주는 입출력 제어 시스템의 설계에 관한 내용을 소개한다. 특히 분산된 PC 시스템 구조와 각 시스템에 탑재될 소프트웨어 모듈들 그리고 TCP/IP를 대신하여 사용하고 있는 필드버스 프로토콜 드라이버의 설계에 관한 내용을 중심으로 소개하고자 한다.

  • PDF

원격 급전소에서 발전소 출력을 제어하기 위한 시스템 연구 (A study on the remote MW control of a steam turbine)

  • 김종안;신윤오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.734-736
    • /
    • 1999
  • The electricity demand has been in the trend of increase for the past 30 years except last year due to economic crisis. The central electrical power dispatch center anticipates each and every hour's electricity demand and dispatch every power plant's output(MW) taking into account of the costs, frequency regulation abilities, locations, reliabilities and so on. to meet the demand as quickly as possible. The large portion of the power plants' output is contolled automatically by the AGC(Automatic Generation Control) function which is a part of the EMS(Energy Manage System) computer in the dispatch center. To receive the electrical power dispatch signal from the EMS, a power plant should have a remote MW control feature in the turbine control system or unit master control system. We investigated the AGC function and a power plant's remote MW control configuration.