• Title/Summary/Keyword: power spectrum analysis

Search Result 884, Processing Time 0.028 seconds

A Study on the Ultrasonic Measurement for Damage Evaluation of Power Plant Bearing (발전용 베어링 손상평가를 위한 초음파 측정 연구)

  • Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1727-1732
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established.

  • PDF

A Study on Nonlinear Distortion Analysis of Power Amplifier using the OFDM for WLAN System (무선랜 시스템에서 OFDM 방식을 사용한 전력증폭기의 비선형 왜곡분석에 관한 연구)

  • Oh Chung-Gyun;Kim Dong-Ok
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.4
    • /
    • pp.42-51
    • /
    • 2003
  • In this paper, we are going to analyze on relation of an output spectrum along phase distortion of power amplifier in wireless LAN system, and then considered an ACPR characteristic of power amplifier and consideration of an OFDM method for this. Also, we did implementation for OFDM modulation and transmission section of an IEEE 802.11a standard to have transmission speed of the maximum 54Mbps in order to know an OFDM modulation method and relation of non-linear characteristic of power amplifier. The non-linear characteristic of power amplifier did modeling with AM-to-AM and AM-to-PM, and we analyzed an output spectrum characteristic along phase distortion composed input signal supply for power amplifier. When output spectrum analysis results phase distortion increased, and an AM-to-PM characteristic of power amplifier in 5 degrees, the output spectrum was satisfied with a demand spectrum in P1 dB, but 10-20 degrees were able to confirm what cannot be satisfied with a demand spectrum in phase distortion. Also, an output spectrum of power amplifier by frequency re-growth generated by a non-linear characteristic of power amplifier did not satisfied in P1dE. therefore, a back-off value was requested according to an AM-to-PM distortion degree, and smaller back-off value were able to know what demand became in case of modulation section that used OFDM.

  • PDF

Interpretating the Spectral Characteristics of Measured Particle Concentrations in Busan (부산지역 대기측정망 자료에 나타난 미세먼지 농도의 시계열 해석)

  • Son, Hye-Young;Kim, Cheol-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.2
    • /
    • pp.133-140
    • /
    • 2009
  • In order to examine the effects of micrometeorological and climatological influences on urban scale particulate air pollutants observed in Busan, power spectrum analysis was applied to the observed particulate matter with aerodynamic diameter ${\le}10{\mu}m$ ($PM_{10}$) for the period from 1991 to 2006. Power spectrum analysis has been employed to the daily mean $PM_{10}$ concentrations obtained at 13 sites to identify different scales of periodicities of $PM_{10}$ concentrations. The results show that, aside from the typical and well-known periodicities such as diurnal and annual variations caused by anthropogenic emission influences, another two significant peaks of power spectrum density were identified: 21 day and $3{\sim}4$ year of periodicities. Cospectrum analysis indicates that the intraseasonal 21 day periodicity are found to be negatively correlated with wind speed and surface pressure but shows consistently positive with relative humidity and temperature. This result implied that 21 day periodicity is presumably relevant to the secondary aerosol formation processes through the photochemical reaction that can be subsequently resulted from hygroscopic characteristics of aerosol formation. However, the interannual $3{\sim}4$ year of periodicity is found to have positive correlation with pressure, and negative with temperature and relative humidity, which is rather consistent with both characteristics of air mass during the Asian dust event and the occurrence frequency of Asian dust whose periodicities have been recorded inter-annually over the Korean peninsula.

Parametric Modelling of Uncoupled System (언커플시스템의 파라메트릭 모델링)

  • Yoon, Moon-Chul;Kim, Jong-Do;Kim, Kwang-Heui
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.3
    • /
    • pp.36-42
    • /
    • 2006
  • The analytical realization of uncoupled system was introduced in this study using times series and its spectrum analysis. The ARMAX spectra of time series methods were compared with the conventional FFT spectrum. Also, the response of second order system uncoupled was solved using the Runge-Kutta Gill method. In this numerical analysis, the displacement, velocity and acceleration were calculated. The displacement response among them was used for the power spectrum analysis. The ARMAX algorithm in time series was proved to be appropriate for the mode estimation and spectrum analysis. Using the separate response of first and second mode, each modes were calculated separately and the response of mixed modes was also analyzed for the mode estimation using several time series methods.

  • PDF

Prediction of Frictional behavior according to geometrical contact condition using FFT-based analysis (FFT해석을 이용한 기하학적 접촉조건에 따른 마찰거동예측)

  • 성인하;이형석;김대은
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.13-18
    • /
    • 2001
  • In this paper, FFT(Fast Fourier Transform) analysis of friction was suggested as a method to interpret the contact conditions. Micro-grooves with various dimensions were fabricated on the silicon surface to investigate the frictional behavior with respect to the change in geometrical contact condition. Frictional forces between micro-grooved surfaces and spheres modeled as surface asperities were measured using a micro-tribotester which was built inside a SEM(Scanning Electron Microscope). The experimental results show that the relative dimensions and distributions of contact asperities between two surfaces can be predicted by the power spectrum and the main frequency in FFT-based analysis of friction coefficient. Also, it was shown that the friction coefficient for multi-asperities was the result of the superposition of that for each asperity.

  • PDF

Formulation and Verification on Ritz Method for In-Cabinet Response Spectrum (캐비닛내부응답스펙트럼 산정을 위한 리츠방법의 정식화 및 단순예제를 통한 검증)

  • Kim, Ki Hyun;Hong, Kee-Jeung;Cho, Sung Gook;Park, Woong Ki
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.279-288
    • /
    • 2019
  • Safety-related cabinets and their electrical parts, such as relays and switches in nuclear power plants, should maintain continuous functioning, as well as structural safety according to the nuclear regulatory guidelines. Generally, an electrical part is qualified if its functioning is maintained without abnormality during excitement by motion compatible with the test response spectrum, which is larger than its in-cabinet response spectrum (ICRS). ICRS can be determined by shake-table test or dynamic analysis. Since existing cabinets in use can hardly be stopped and moved, dynamic analysis is preferred over shake-table test in determining ICRS. The simple method, suggested by the Electric Power Research Institute (EPRI) to determine ICRS, yields conservative or non-conservative results from time to time. In order to determine that the ICRS is better than EPRI method in a simple way, Ritz method considering global and local plate behaviors was suggested by Gupta et al. In this paper, the Ritz method is modified in order to consider the rocking and frame behaviors simultaneously, and it is applied to a simple numerical example for verification. ICRS is determined by Ritz method and compared with the results by finite element method (FEM). Based on this numerical example, recommendations for using Ritz method are suggested.

On Power Allocation Schemes for Bi-directional Communication in a Spectrum Sharing-based Cognitive Radio System

  • Kim, Hyungjong;Wang, Hanho;Hong, Daesik
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.5
    • /
    • pp.285-297
    • /
    • 2014
  • This paper presents the results of an investigation into bi-directional communication in spectrum sharing-based cognitive radio (Bi-CR) systems. A Bi-CR system can increase the spectral efficiency significantly by sharing the spectrum and through the bi-directional use of spatial resources for two-way communication. On the other hand, the primary user experiences more interference from the secondary users in a Bi-CR system. Satisfying the interference constraint by simply reducing the transmission power results in performance degradation for secondary users. In addition, secondary users also experience self-interference from echo channels due to full duplexing. These imperfections may weaken the potential benefits of the Bi-CR system. Therefore, a new way to overcome these defects in the Bi-CR system is needed. To address this need, this paper proposes some novel power allocation schemes for the Bi-CR system. This contribution is based on two major analytic environments, i.e., noise-limited and interference-limited environments, for providing useful analysis. This paper first proposes an optimal power allocation (OPA) scheme in a noise-limited environment and then analyzes the achievable sum rates. This OPA scheme has an effect in the noise-limited environment. In addition, a power allocation scheme for the Bi-CR system in an interference-limited environment was also investigated. The numerical results showed that the proposed schemes can achieve the full duplexing gain available from the bi-directional use of spatial resources.

Analysis of Motor-Current Spectrum for Fault Diagnosis of Induction Motor Bearing in Desulfurization Absorber (탈황 흡수탑 유도전동기 베어링 결함 진단을 위한 전류 스펙트럼 해석)

  • Bak, Jeong-Hyeon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.11 no.2
    • /
    • pp.39-44
    • /
    • 2015
  • According to a research that is based on a previous study, But in a different way, This study shows fault diagnosis of Induction motor bearing which runs in coal-fired power plant industries on Desulfurization absorber agitator using Spectrum analysis of Stator Current and visual inspection. As a result of harmonic content analysis of stator current spectrum, It was possible to detect ball and outer race fault frequency. The comparison in the context of this experiment proves that the amplitude of faulty frequency is increased in three times at a fault in ball and in outer race. Spectrum analysis of stator current can be used to detect the presence of a fault condition as well as experiment in faulty bearings, besides early fault detection in bearings can prevent unexpected power generation loss and emergency maintenance cost.

  • PDF

Performance Analysis of an Energy Detection Based Cooperative Spectrum Sensing with a Single Threshold in the Presence of Noise Uncertainty (잡음 전력의 불확실성이 존재하는 환경에서 단일 임계값을 사용하는 에너지 검파 기반 협력 스펙트럼 감지의 성능 분석)

  • Lim, Chang Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1406-1411
    • /
    • 2012
  • An energy detection based spectrum sensing has been found to be vulnerable to the noise power uncertainty. A cooperative spectrum sensing with an energy detector has appeared as one of the solutions to alleviate this difficulty. However, its performance analysis in a fading environment has not been reported yet in the literature. Motivated by this, this paper presents the performance analysis of the scheme by extending our previous work on evaluating the performance of an energy detector in the presence of noise power uncertainty. The analysis shows that the false alarm probability and detection probability gets higher as the sensing time and/or the number of the secondary users in the OR based cooperative spectrum sensing scheme increase when the noise power uncertainty exists.

Seismic Qualification of the Air Cleaning Units for Nuclear Power Plant Ulchin 5&6 (울진 원자력발전소 5,6 호기용 공기정화기에 대한 내진검증)

  • Kim, Jin-Young;Rhee, Hui-Nam;Lee, Joon-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1376-1383
    • /
    • 2002
  • Seismic qualification of the Air Cleaning Units for nuclear power plant Ulchin 5&6 has been performed with the guideline of ASME Section III and IEEE 344 code. By using the structural and geometrical similarity analysis, the three models to be analyzed are condensed into a single model and, at the same time, the excitation forces and other operating loads for each model are encompassed with respect to different loading conditions. As the fundamental frequencies of the structure are found to be less than 33Hz, which is the upper frequency limit of the seismic load, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the structural and electric stability of the major components, modal analysis theory is adopted to derive the required response spectrum at the component locations. As the all combined stresses obtained from the above procedures are less than allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors confirm the safety of the nuclear equipments Air Cleaning Units studied in this paper.