• Title/Summary/Keyword: power quality

Search Result 5,333, Processing Time 0.036 seconds

Exploiting Quality Scalability in Scalable Video Coding (SVC) for Effective Power Management in Video Playback (계층적 비디오 코딩의 품질확장성을 활용한 전력 관리 기법)

  • Jeong, Hyunmi;Song, Minseok
    • KIISE Transactions on Computing Practices
    • /
    • v.20 no.11
    • /
    • pp.604-609
    • /
    • 2014
  • Decoding processes in portable media players have a high computational cost, resulting in high power consumption by the CPU. If decoding computations are reduced, the power consumed by the CPU is also be reduced, but such a choice generally results in a degradation of the video quality for the users, so it is essential to address this tradeoff. We proposed a new CPU power management scheme that can make use of the scalability property available in the H.164/SVC standard. We first proposed a new video quality model that makes use of a video quality metric(VQM) in order to efficiently take into account the different quantization factors in the SVC. We then propose a new dynamic voltage scaling(DVS) scheme that can selectively combine the previous decoding times and frame sizes in order to accurately predict the next decoding time. We then implemented a scheme on a commercial smartphone and performed a user test in order to examine how users react to the VQM difference. Real measurements show that the proposed scheme uses up to 34% fewer energy than the Linux DVFS governor, and user tests confirm that the degradation in the quality is quite tolerable.

A Study on the Emotional Adjective Extraction and Subjective Evaluation of Sound Quality for Vehicle Power Seat (차량용 파워 시트 작동음의 감성 어휘 추출 및 주관적 음질 평가에 관한 연구)

  • Kim, Sung-Yuk;Jang, Ju-Gwang;Ji, Hyo-Seong;Kim, Ok-Whan;Kim, Key-Sun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.2
    • /
    • pp.29-37
    • /
    • 2019
  • In this study, emotional adjectives about the operating sound quality of the vehicle power seat are constructed, and the effectiveness of the emotional adjectives are verified by evaluating the operating sound quality. First, emotional adjectives were collected from the literature related to the automobile field and other sound qualities. A questionnaire was made using these adjectives. The questionnaire was designed to be able to select all adjectives that could express the operating noise of the power seat slide adjuster by applying the multiple- response method. Next, a subjective sound quality evaluation was conducted using the emotional adjectives. In the evaluation, we first recorded the operating noise for two power seats. Second, the subjective sound quality evaluation was performed on the recorded operating noise using a loudspeaker. Finally, through a statistical analysis on the sound quality evaluation results, the relationship between the semantic space and the preference score was verified, and the validity of the emotional adjectives was verified.

A Study on the Quality Characteristic of Power Bio-Fuel Oil for Alternative Fuel oil (중유 대체연료로서 발전용 바이오중유의 품질특성 연구)

  • Jang, Eun-Jung;Park, Jo-Yong;Min, Kyung-Il;Yim, Eui-Soon;Ha, Jong-Han;Lee, Bong-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.562-571
    • /
    • 2014
  • In these days, many countries carry out many renewable energy policies to increase the renewable energy portion and to reduce the GHG(Green House Gas). In Korea, RPS(Renewable Portfolio Standards) focused on over 500MW power producers is conducting. And they are using the bio-fuel oil to meet their RPS quota. The oil is a mixture of animal and vegetable fat or fatty acid ester of them and should satisfy some specifications to use the power generation such as viscosity, pour point, acid number. Depends on the raw materials, quality characteristics of power bio-fuel oil are changed. By adding the power bio-fuel oil, pour point, density, sulfur content and viscosity are decreased and acid number, iodine number, oxygen content are increased. In this study, we test the quality characteristic of power bio-fuel oil and the property changes by the blending ratio of power bio-fuel oil & conventional fuel oil.

Characterization and Performance Evaluation of Advanced Aircraft Electric Power Systems

  • Eid, Ahmad;El-Kishky, Hassan;Abdel-Salam, Mazen;El-Mohandes, Mohamed T.
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.563-571
    • /
    • 2010
  • A model of an advanced aircraft electric power system is developed and studied under variable-speed constant-frequency (VSCF) operation. The frequency of the generator's output voltage is varied from 400-Hz to 800-Hz for different loading scenarios. Power conversions are obtained using 12-pulse power converters. To reduce the harmonic contents of the generator output waveforms, two high-pass passive filters are designed and installed one at a time at the generator terminals. The performance of the two passive filters is compared according to their losses and effectiveness. The power quality characteristics of the studied VSCF aircraft electric power system are presented and the effectiveness of the proposed filter is demonstrated through compliance with the newly published aircraft electrical standards MIL-STD-704F.

The Effects of Standardization for the Nuclear Power Plants in Korea

  • Kim, Kyoung-Pyo;Kim, Seung-Su;Lee, Young-Gun
    • Journal of Korean Society for Quality Management
    • /
    • v.18 no.2
    • /
    • pp.69-80
    • /
    • 1990
  • This paper highlights the economic effects of nuclear power plants standardization in Korea. The major effects of nuclear power plants standardization appear in the reduction of time-related costs. By using this major economic effects of standardization, an optimal plant mix of electric power until the year 2005 is suggested by means of WASP computer model. And the effects between the standardized case and the non-standardized case is compared.

  • PDF

-Reliability Assessment of Nuclear Power Plants Considering the Qualitative Factors under Uncertainty- (원자력발전소에서 정성적 요인을 고려한 신뢰성 평가)

  • 강영식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.54
    • /
    • pp.167-177
    • /
    • 2000
  • The problem of system reliability is very important issue in the nuclear power plant, because the failure of its system brings about extravagant economic loss, environment destruction, and quality loss. This paper therefore proposes a normalized scoring model by the qualitative factors order to evaluate the robust reliability of nuclear power plants under uncertainty. Especially, the qualitative factors including risk, functional, human error, and quality function factors for the robust justification has been also introduced. Finally, the analytical reliability and safety assessment model developed in this paper can be used in the real nuclear power plant.

  • PDF

An Efficient Control Strategy Based Multi Converter UPQC using with Fuzzy Logic Controller for Power Quality Problems

  • Paduchuri, Chandra Babu;Dash, Subhransu Sekhar;Subramani, C.;Kiran, S. Harish
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.379-387
    • /
    • 2015
  • A custom power device provides an integrated solution to the present problems that are faced by the utilities and power distribution. In this paper, a new controller is designed which is connected to a multiconverter unified power quality conditioner (MC-UPQC) for improving the power quality issues adopted modified synchronous reference frame (MSRF) theory with Fuzzy logic control (FLC) technique. This newly designed controller is connected to a source in order to compensate voltage and current in two feeders. The expanded concept of UPQC is multi converter-UPQC; this system has a two-series voltage source inverter and one shunt voltage source inverter connected back to back. This configuration will helps mitigate any type of voltage / current fluctuations and power factor correction in power distribution network to improve power quality issues. In the proposed system the power can be conveyed from one feeder to another in order to mitigate the voltage sag, swell, interruption and transient response of the system. The control strategies of multi converter- UPQC are designed based on the modified synchronous reference frame theory with fuzzy logic controller. The fast dynamics response of dc link capacitor is achieved with the help of Fuzzy logic controller. Different types of fault conditions are taken and simulated for the analysis and the results are compared with the conventional method. The relevant simulation and compensation performance analysis of the proposed multi converter-UPQC with fuzzy logic controller is performed.

T2PC: Temperature-aware Transmission Power Control Scheme for Wireless Sensor Networks (무선 센서 네트워크를 위한 온도인지형 전송파워 제어 기법)

  • Lee, Jung-Wook;Chung, Kwang-Sue
    • Journal of KIISE:Information Networking
    • /
    • v.37 no.5
    • /
    • pp.403-408
    • /
    • 2010
  • The sensor nodes can be installed in the environment in which the temperature change is considerable, such as desert, urban, and data center. Particularly, because the output power becomes less than the targeted power if a temperature is increasing, link quality is degraded and packet losses are occurred. In order to compensate the temperature changes, existing schemes detect the change of the link quality between nodes and control transmission power through a series of feedback process. However, these approaches can cause heavy overhead by additional control packets. In this paper, we propose the T2PC(Temperature-aware Transmission Power Control) to keep up the link quality despite temperature variation. At each node, T2PC compensates the attenuated link quality by controlling the transmission power based on the local temperature measurement. In addition, the packet reception ratio can be improved with less control packets than ones required in existing transmission power control methods based on the feedback control.

A Study on the Utilization of Air Quality Model to Establish Efficient Air Policies: Focusing on the Improvement Effect of PM2.5 in Chungcheongnam-do due to Coal-fired Power Plants Shutdown (효율적인 대기정책 마련을 위한 대기질 모델 활용방안 고찰: 노후 석탄화력발전소 가동중지에 따른 충남지역 PM2.5 저감효과 분석을 중심으로)

  • Nam, Ki-Pyo;Lee, Dae-Gyun;Lee, Jae-Bum;Choi, Ki-Cheol;Jang, Lim-Seok;Choi, Kwang-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.5
    • /
    • pp.687-696
    • /
    • 2018
  • In order to develop effective emission abatement strategies for coal-fired power plants, we analyzed the shutdown effects of coal-fired power plants on $PM_{2.5}$ concentration in June by employing air quality model for the period from 2013 to 2016. WRF (Weather Research and Forecast) and CMAQ(Community Multiscale Air Quality) models were used to quantify the impact of emission reductions on the averaged $PM_{2.5}$ concentrations in June over Chungcheongnam-do area in Korea. The resultant shutdown effects showed that the averaged $PM_{2.5}$ concentration in June decreased by 1.2% in Chungcheongnam-do area and decreased by 2.3% in the area where the surface air pollution measuring stations were located. As a result of this study, it was confirmed that it is possible to analyze policy effects considering the change of meteorology and emission and it is possible to quantitatively estimate the influence at the maximum impact region by utilizing the air quality model. The results of this study are expected to be useful as a basic data for analyzing the effect of $PM_{2.5}$ concentration change according to future emission changes.

Development of Matlab/Simulink Module for Voltage Flicker Simulation in Distribution Power Systems

  • Cho, Soo-Hwan;Jung, Jae-Ahn;Jang, Gil-Soo;Kwon, Sae-Hyuk;Kang, Moon-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.314-319
    • /
    • 2008
  • Power quality simulation plays an important role in many practical cases, for example, when deciding the capacity of the related mitigation devices, assessing the influence of installing a nonlinear load in the distribution part, dissolving the quality issues between utilities and customers, and so on. For these purposes, many dedicated tools have been used in order to assess the level of quality distortions by various kinds of PQ indices. However, there are few modules that can accurately simulate the flicker phenomenon, that is, $P_{st}$ and the nonlinear and chaotic behavior of the electrical arc furnace, which is one of the representative nonlinear loads. This paper deals with the useful and simple modules for the voltage flicker simulation in the distribution and transmission level under the environment of Matlab/Simulink. With these modules, the various conditions of distribution systems and the capacities of arc furnaces with the chaotic characteristic can be easily taken into account.