• 제목/요약/키워드: power plant modeling

검색결과 375건 처리시간 0.032초

Modeling of chloride diffusion in concrete considering wedge-shaped single crack and steady-state condition

  • Yang, Keun-Hyeok;Cheon, Ju Hyun;Kwon, Seung-Jun
    • Computers and Concrete
    • /
    • 제19권2호
    • /
    • pp.211-216
    • /
    • 2017
  • Crack on concrete surface allows more rapid penetration of chlorides. Crack width and depth are dominant parameters for chloride behavior, however their effects on chloride penetration are difficult to quantify. In the present work, the previous anisotropic (1-D) model on chloride diffusion in concrete with single crack is improved considering crack shape and roughness. In the previous model, parallel-piped shape was adopted for crack shape in steady-state condition. The previous model with single crack is improved considering wedge shape of crack profile and roughness. For verifying the proposed model, concrete samples for nuclear power plant are prepared and various crack widths are induced 0.0 to 1.2 mm. The chloride diffusion coefficients in steady-state condition are evaluated and compared with simulation results. The proposed model which can handle crack shape and roughness factor is evaluated to decrease chloride diffusion and can provide more reasonable results due to reduced area of crack profile. The roughness effect on diffusion is evaluated to be 10-20% of reduction in chloride diffusion.

태양광발전 어레이 표면의 냉각/세정에 대한 장기 실증 실험 (Long-term Experiments of the Cooling/Cleaning on the surface of the PV Power Array)

  • 한준선;김이현;지희관;유상필
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.248-254
    • /
    • 2012
  • In the situation of expanding domestic solar power supply business long-term performance modeling of a proposed solar-cooling and cleaning system to increase electromotive force and light transmission is carried out to test the effectiveness of the system. To test the effectiveness of the system, the data which comparing the solar power planet installing the system to not installing at the same time is used. A difference between the utilization factor of each comparison group were recorded. Approximately from one year to two years Field Test was performed, Result of apply to cooling/cleaning technology, Each of plant by From least 7 percent up to 16 percent utilization factor increased, and the cooling / cleaning is output through improved as a result of the determined.

  • PDF

발전소내 스위치야드 및 주변압기간 연결선로의 적정 피뢰기 위치 선정 (A STUDY ON EFFECTIVE APPLICATION OF SURGE ARRESTER BETWEEN THE SWITCHYARD AND MAIN TRANSFORMER IN POWER PLANT)

  • 이흥찬;함영수;정기수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.503-505
    • /
    • 1995
  • The surge arrester plays a vital role in the protection of substation against transient overvoltages resulting from lightning surges and system switching operations. The proper selection and application of the surge arrester is an integral part of the process of substation equipment insulation level selection. The paper outlines the basic consideration in modeling the lightning stroke, the surge arrester, and the system to be protected. The paper discusses the results of various cases simulated using the alternative transient computer program to evaluate the separation effects.

  • PDF

The μ-synthesis and analysis of water level control in steam generators

  • Salehi, Ahmad;Kazemi, Mohammad Hosein;Safarzadeh, Omid
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.163-169
    • /
    • 2019
  • The robust controller synthesis and analysis of the water level process in the U-tube system generator (UTSG) is addressed in this paper. The parameter uncertainties of the steam generator (SG) are modeled as multiplicative perturbations which are normalized by designing suitable weighting functions. The relative errors of the nominal SG model with respect to the other operating power level models are employed to specify the weighting functions for normalizing the plant uncertainties. Then, a robust controller is designed based on ${\mu}$-synthesis and D-K iteration, and its stability robustness is verified over the whole range of power operations. A gain-scheduled controller with $H_{\infty}$-synthesis is also designed to compare its robustness with the proposed controller. The stability analysis is accomplished and compared with the previous QFT design. The ${\mu}$-analysis of the system shows that the proposed controller has a favorable stability robustness for the whole range of operating power conditions. The proposed controller response is simulated against the power level deviation in start-up and shutdown stages and compared with the other concerning controllers.

파라미터 보간법을 이용한 3MW급 MCFC 시스템의 정상 및 비정상 상태 설계 (Steady and Dynamic Modeling of 3MW MCFC System Conceptual Design Using Parameter Interpolation Method)

  • 김민기;조인정;김윤미;강민관;이상훈;김재식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.87.2-87.2
    • /
    • 2010
  • The steady and dynamic process model for an internal reforming molten carbonate fuel cell power plant is discussed in this paper. The dominant thermal and chemical dynamic processes are modeled for the stack module and balance-of-plant, including cathode gas preparation, heat recovery, heat loss (Each heat loss amount for the stack and MBOP is obtained from real plant data) and fuel processing. Based on dynamic model and control demand, PID controllers are designed in the whole system. By applying these controllers we can obtain temperature balance of stack and control system depending on changing steam to carbon ratio, air feed amount, and transient condition.

  • PDF

전력계통 안정성 향상을 위한 발전기 제어계 특성시험 및 모델링 (Generator Testing and Model Validation for Thermal Plant)

  • 차승태;김용학;오세일;최준호;신정훈;심응보;곽노홍;손현일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.473-474
    • /
    • 2007
  • The Jeju power grid experienced several major power disturbances over the last decade. The postmortem studies of the incidents indicated that some of the generating units did not respond as predicted by system analysis & studies. Consequently, the Korean Power Exchange (KPX) mandated that all units (generators, excitation, governor and turbine systems) in the Korean network greater than or equal to 20MVA be tested to verify the generator reactive power limits as well as the dynamic model data being used for system studies. This paper presents field experiences of the authors in testing and modeling of steam turbines and their associated governors during the generator and model validation.

  • PDF

공간정보 모델링을 이용한 원전 사고의 환경 영향 평가: 체르노빌 사례연구 (Environmental Impact Assessment of Nuclear Power Plant Accident using Spatial Information Modeling: A Case Study of Chernobyl)

  • 이상원;송아람;박노욱
    • 대한원격탐사학회지
    • /
    • 제28권1호
    • /
    • pp.129-143
    • /
    • 2012
  • 이 논문은 1986년에 발생한 체르노빌 원전 사고 사례연구를 통해 환경 모니터링과 영향 평가를 위한 고급 공간정보 모델링 기술의 유용성을 예시하였다. 사고지점 주변에서 1986년과 1992년에 촬영된 Landsat TM 영상자료를 대상으로 선분류 후비교법을 적용하여 변화가 크게 일어난 지역과 토지피복 변화 양상을 분석하였다. 그리고 이 사고의 가장 큰 피해지역으로 알려진 벨로루시 지역을 대상으로 다양한 크리깅 기법을 포함한 공간 모델링 기법을 적용하여 토양 내 세슘 농도와 갑상선 암 발병률 자료와의 상관성을 분석하였다. 변화 탐지 결과, 농경지 면적의 감소와 황무지 면적의 증가가 가장 뚜렷하게 나타났고, 방사능 오염의 확산을 막기 위한 콘크리트 구조물들이 새롭게 생겨난 것을 확인할 수 있었다. 벨로루시 지역의 영향평가 결과, 세슘 오염이 심한 원전 인근 지역에서 포아송 크리깅에 의해 추정된 위험도가 상대적으로 높게 나타났다. 세슘 농도와 사고지점과의 거리를 독립 변수로 사용하여 이 변수들의 공간 변화 양상을 반영할 수 있는 지리적 가중 회귀분석을 적용하였다. 적용 결과, 갑상선 암 위험도와 상관계수 0.98을 나타내는 갑상선 암 발병 위험도 추정이 가능하였으며, 이는 원전 사고가 갑상선 암 발병 위험도에 영향을 준 것을 의미한다. 결론적으로 이 연구에서 적용한 공간정보 모델링 기법들은 환경 영향 평가 및 환경 보건 분야에서 유용하게 사용될 수 있을 것으로 기대된다.

Unstable Operation of Francis Pump-Turbine at Runaway: Rigid and Elastic Water Column Oscillation Modes

  • Nicolet, Christophe;Alligne, Sebastien;Kawkabani, Basile;Simond, Jean-Jacques;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.324-333
    • /
    • 2009
  • This paper presents a numerical simulation study of the transient behavior of a $2{\times}340MW$ pump-turbine power plant, where the results show an unstable behavior at runaway. First, the modeling of hydraulic components based on equivalent schemes is presented. Then, the 2 pump-turbine test case is presented. The transient behavior of the power plant is simulated for a case of emergency shutdown with servomotor failure on Unit 1. Unstable operation at runaway with a period of 15 seconds is properly simulated using a 1-dimensional approach. The simulation results points out a switch after 200 seconds of the unstable behavior between a period of oscillations initially of 15 seconds to a period of oscillation of 2.16 seconds corresponding to the hydraulic circuit first natural period. The pressure fluctuations related to both the rigid and elastic water column mode are presented for oscillation mode characterization. This phenomenon is described as a switch between a rigid and an elastic water column oscillation mode. The influence of the rotating inertia on the switch phenomenon is investigated through a parametric study.

Development of Field Programmable Gate Array-based Reactor Trip Functions Using Systems Engineering Approach

  • Jung, Jaecheon;Ahmed, Ibrahim
    • Nuclear Engineering and Technology
    • /
    • 제48권4호
    • /
    • pp.1047-1057
    • /
    • 2016
  • Design engineering process for field programmable gate array (FPGA)-based reactor trip functions are developed in this work. The process discussed in this work is based on the systems engineering approach. The overall design process is effectively implemented by combining with design and implementation processes. It transforms its overall development process from traditional V-model to Y-model. This approach gives the benefit of concurrent engineering of design work with software implementation. As a result, it reduces development time and effort. The design engineering process consisted of five activities, which are performed and discussed: needs/systems analysis; requirement analysis; functional analysis; design synthesis; and design verification and validation. Those activities are used to develop FPGA-based reactor bistable trip functions that trigger reactor trip when the process input value exceeds the setpoint. To implement design synthesis effectively, a model-based design technique is implied. The finite-state machine with data path structural modeling technique together with very high speed integrated circuit hardware description language and the Aldec Active-HDL tool are used to design, model, and verify the reactor bistable trip functions for nuclear power plants.

Modeling of the Environmental Behavior of Tritium Around the Nuclear Power Plants

  • Park, Heui-Joo;Lee, Hansoo;Kang, Hee-Suk;Park, Yong-Ho;Lee, Chang-Woo
    • Nuclear Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.242-249
    • /
    • 2002
  • The relationship between the tritium release rate from the nuclear power plant and tritium concentration in the environment around the Kori site was modeled. The tritium concentration in the atmosphere was calculated by multiplying the release rates and $\chi$/Q values, and the d3V deposition rate at each sector according to the direction and the distance was obtained using a dry deposition velocity. The area around Kori site was divided into 6 zones according to the deposition rate. The six zones were divided into 14 compartments for the numerical simulation. Transfer coefficients between the compartments were derived using site characterization data. Source terms were calculated from the dry deposition rates. Tritium concentration in surface soil water and groundwater was calculated based upon a compartment model. The semi-analytical solution of the compartment model was obtained with a computer program, AMBER. The results showed that most of tritium deposited onto the land released into the atmosphere and the sea. Also, the estimated concentration in the top soil agreed well to that measured. Using the model, tritium concentration was predicted in the case that the tritium release rates were doubled.