• 제목/요약/키워드: power performance testing

검색결과 463건 처리시간 0.034초

국내 IED 시작품대상 IEC 61850 통신서비스 성능 검증에 관한 연구 (Study on the performance verification of IEC 61850 communication service on domestic IEDs)

  • 이남호;장병태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.3-5
    • /
    • 2008
  • Korea Electric Power Research Institute has being carried out an IEC 61580 based communication service test on domestic IED trial products developed related to power IT project. This paper describes IEC 61850-10 conformance test and testing items established by UCA international Users Group and this study is on the analysis of testing results from IED communication service with selected testing blocks, which consist of Basic association, Dataset, Reporting and GOOSE.

  • PDF

IEC 61850 기반 IED 시스템 성능 시험 절차서에 관한 연구 (Study on the Testing Procedures of IED System Performance based on IEC 61850)

  • 이남호;장병태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1-2
    • /
    • 2008
  • Korea Electric Power Research Institute has carried out verification of communication conformance on IEC 61850 based IEDs related to power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology". Owing to IEC 61850 international standard and digital substation automation system, IED testing process should be changed from the conventional way to the new way described in the paper. This paper describes IED testing procedures based on substation automation system using UML.

  • PDF

한류형 전력퓨즈의 차단성능평가 위한 단락시험에 관한 고찰 (Consideration On Short Circuit Tests For Evaluation Of Breaking Performance Of Current-Limiting Fuses)

  • 김대원;서윤택;윤학동;정희재;김맹현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.543-545
    • /
    • 2003
  • 한류형 전력퓨즈는 계통의 단락사고로 고장 전류가 흐를 때 퓨즈내부에서 발생하는 저항에 의해 고장전류를 회로 고유의 단락전류보다 아주 적은 값으로 제한하고 최소 시간내에 차단하여 회로를 보호하므로 계통기기의 단락용량를 최소한으로 감소시킬 수 있다. 본 논문에서는 이러한 한류형 전력퓨즈의 단락전류 차단성능 평가를 위해 동작책무에 따른 차단성능을 규명하고자 단락발전기를 사용하여 단락전류차단시험을 실시하고 그 결과를 제시하였으며, 또한 차단과정에 따른 스트레스들이 단락시험 시 차단성능에 미치는 영향을 다루고 있다.

  • PDF

원전 증기발생기 와전류검사 시스템 개발 (A Development of Eddy Current Testing System for Steam Generators Inspection in Nuclear Power Plants)

  • 문균영;조찬희;유현주;이태훈;조용배
    • 한국압력기기공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.40-47
    • /
    • 2013
  • The capacity factor of nuclear power plant in Korea is the highest level in the world. However, the integrity assessment of nuclear power plant is depended on foreign country. Especially, most eddy current testing systems for inspecting steam generators in nuclear power plant are currently imported from USA, Canada, and so on. Therefore, the eddy current testing system can react more active and adaptive from economic and managerial standpoint for actual nuclear power plants in Korea is required. In this paper, an eddy current testing system for inspecting steam generators in nuclear power plants is introduced. Frequency generator, analog circuit, analog digital converter circuit, and digital control circuit are composed in eddy current testing system. A benchmarking of acquisition system and acquisition software, eddynet 11i made by Zetec, and modifications are carried out based on the test environment of Korea nuclear power plants. Finally, all eddy current apparatus are integrated to inspect steam generator tubes in nuclear power plants.

전력용 변압기 보호를 위한 통합보호제어장치의 하드웨어 설계와 실시간 성능 시험 (Real-time Testing and Hardware Design of Intelligent Electronic Device for Power Transformer Protection)

  • 박철원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.122-127
    • /
    • 2005
  • This paper proposes a prototype IED hardware design and it's real-time experimental results. To evaluate performance of the IED, the study is well constructed power system model including power transformer utilizing the EMTP software and the testing is made through simulation of various cases. The relaying that is well constructed using DSP chip and RISC CPU etc. has been developed and the prototype IED has been verified through on-line testing by LabVIEW simulator. The results show that an advanced relaying based prototype IED never mis-operated.

  • PDF

1.5MW 풍력발전시스템 출력 성능시험 및 불확도 분석 (Power Performance Testing and Uncertainty Analysis for a 1.5MW Wind turbine)

  • 김건훈;주영철;김대호
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.63-71
    • /
    • 2006
  • The installed capacity of wind turbines in KOREA are growing and enlarging by the central government's support program. Thus, the importance of power performance verification and its uncertainty analysis are recognizing rapidly. This paper described the Power testing results of a 1.5MW wind turbine and analysed an uncertainty level of measurements. The measured power curves are very closely coincide with the calculated one and the annual power production under the given Rayleigh wind speed distribution are estimated with the $4.7{\sim}22.0%$ of uncertainty but, in the dominant wind speed region as $7{\sim}8m/s$, the uncertainty are stably decreased to $7{\sim}8%$.

히트펌프 온수기 개발을 위한 계측 및 성능평가시스템 구축 (Development of Measurement and Performance Testing System for Heat Pump water Heater)

  • 권성철;양승권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2310-2312
    • /
    • 2004
  • In Korea Electric Power Corporation (or KEPCO), several Demand-Side Management (or DSM) program have been carried out to effectively meet electric power demand at least costs by modifying customers electricity use patterns. As one of them, KEPCO applies low-priced night thermal-storage power service for heat appliances to facilitate efficient use of power facilities by shifting relatively high daytime demands to night hours to build loads during the off-peak periods. In the market of heat-storage type water-heater, electric water-heater has been mostly used, but it has low energy efficiency and needs high capacity electric equipments. So in order to replace these electric water heaters, 15 HP air-source heat pump water heater is developed in Korea Electric Research Institute (or KEPRI). This paper shows that measurement system for performance testing of heat pump water heater is established and heating capacity and performance is analyzed and measured for out-door environmental change.

  • PDF

3MW 풍력발전시스템 출력 성능시험 및 불확도 분석 (Power Performance Testing and Uncertainty Analysis for a 3MW Wind Turbine)

  • 김건훈;현승건
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.10-15
    • /
    • 2010
  • The installed capacity of wind turbines in KOREA are growing and enlarging by the central government's support program. Thus, the importance of power performance verification and its uncertainty analysis are recognizing rapidly. This paper described the power testing results of a 3MW wind turbine and analysed an uncertainty level of measurements. The measured power curves are very closely coincide with the calculated one and the annual power production under the given Rayleigh wind speed distribution are estimated with the 3.6~12.7% of uncertainty but, in the dominant wind speed region as 7~8m/s, the uncertainty are stably decreased to 6.3~5.3%.

전지관리장치(BMS)의 서지내성 성능향상 기법 (Surge Immunity Performance Enhancement Techniques on Battery Management System)

  • 김용성;임성정;서우현;정중일
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.196-200
    • /
    • 2015
  • The switching noise in the power electronics of the power conversion equipment (Power Conditioning System) for large energy storage devices are generated. Since the burst-level transient noise from being generated in the power system at a higher power change process influences the control circuit of the low voltage driver circuit. Noise may cause the malfunction of the control device even if no dielectric breakdown leads to a control circuit. To overcome this, this paper proposes the installation of an additional nano-surge protection device on the power supply DC output circuit of the battery management unit.

다결정 실리콘 태양광 모듈의 옥외 성능 평가 (Outdoor Performance Evaluation of Multi-Crystalline Silicon Photovoltaic Module)

  • 이유리;김우경;정재학
    • Current Photovoltaic Research
    • /
    • 제7권3호
    • /
    • pp.71-75
    • /
    • 2019
  • Solar energy is one of the renewable energy sources. It can respond to expanding energy demand. A solar cell module is designed to have a durability that can be developed over a long period of 25 years to be installed outdoors and perform like a stable power supply. We need Standard Test Condition (STC)-based power output data before and after testing to measure the power output of existing modules. The modules are shown to reduce power output by comparing data before and after outdoor experiments regardless of whether they are indoor or outdoor. It is easy to compare the power output quantities through the module simulator in the indoor. However, it takes a lot of testing time and costs to compare the power output on outdoor in the case of a high number of modules and distance from the module simulator. It can save time and costs if we can check the power output using the data in outdoor. We have used the long-term outdoor test to find the elements out that corresponds to the reductions in power output quantities. We have conducted research that matched the actual and the tests.