• Title/Summary/Keyword: power of test

Search Result 10,072, Processing Time 0.039 seconds

Development and Test of a Cooling System for a 154 kV Superconducting Fault Current Limiter

  • Kim, Heesun;Han, Young Hee;Yang, Seong-Eun;Yu, Seung-Duck;Park, Byung Jun;Park, Kijun;Yoo, Jaeun;Kim, Hye-Rim;In, Sehwan;Hong, Yong Joo;Yeom, Hankil
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.141-144
    • /
    • 2015
  • The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.

Substation Power Quality Test of Hanvit 350 running (한국형 고속열차 주행시 전철변전소 전력품질 시험)

  • Lee, Tae-Hyung;Park, Choon-Soo;Im, Young-Chan;Choi, Seong-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1479-1481
    • /
    • 2007
  • It is important to evaluate the power quality at a substation when a test train is running. Especially, the Korea Electric Power Company(KEPCO) restrict the power quality generated from the electrical train within limited value. So, this paper represents the results of the power quality test when Hanvit 350 is running at the KTX high speed line and the assessment.

  • PDF

A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System (특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구)

  • Jung, Heung-Soo;Kim, Min-Young;Kim, Juen-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.36-46
    • /
    • 2008
  • This paper is to study on the Construction of Test circuit and Unification of Experiment Method for high voltage gas-insulated load switch using high power testing system The high power testing system is a equipment to verify electrical and mechanical performance on electrical product. The system consist of short-circuit generator, back-up breaker, making switch, impedance, high voltage transformer, low voltage transformer, measuring and protection system, etc. Using this system, we can test related to high power, for example, short-time current test, active load Current test, magnetizing Current test, capacitive current test, closed loop current test, etc. Standards of high voltage gas-insulated load switch that is in use domestic distribution line are ES 5925-0002, IEC 60265-1, IEC 62271-1 and IEEE C 37.74, etc. In this paper, we standardized on the test procedure, organization of test circuit and analysis of measured data prescribed many difference standards, and applied this test method to 600[MVA] high power testing system. So that we can test the load switch satisfied standards.

A Study on Verification of PowerRail based on Voltage Drop under Extended Feeding Condition (연장급전 전압강하 계산을 위한 전기철도 급전 시뮬레이터의 검증에 관한 연구)

  • Kim, Joorak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.331-337
    • /
    • 2015
  • The power flow analysis of electrified railway is required complicated calculation, because of variable load. Train runs trough rail supplied by electric power therefore, the load value in electrified railway system fluctuates along time. The power flow algorithm in electrified railway system is different from general power system, and the power flow simulation is peformed by the particular simulation software. Powerail is simulation software for analysis of traction power supply system developed by KRRI, in 2008. This consists of load forecasting module, including TPS and time scheduling, and power flow module. This software was verified by measured current under normal feeding condition, however, has not been verified by voltage on the condition of extended feeding. This paper presents the verification of PowerRail based on voltage drop under extended feeding condition. This is performed by comparing simulation result with field test. Field test and simulation is done in commercial railway line.

A Study on the Evaluation of Turbine Efficiency through the Performance Test of New Power Plant (신규 화력발전소의 성능 시험을 통한 터빈 효율의 평가에 관한 연구)

  • Kweon, Y.S.;Chung, H.T.;Jung, Y.B.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • Super-critical type steam power plant, which operates with steam pressure above the super-critical point, has a good reputation recently and is adopted as a new standard of the Korean Electric Power Corporation. The reason for the good reputation lies in it's superior power efficiency. However, the field data of the new power plant for the verification of it's performance are still insufficient, and more empirical data are needed to acquire technologies on the effective operation of it. In this study, the authors analyzed the field test data on power efficiencies got in a super-critical type steam power plant, and evaluated the excellency of the new plant by comparing the efficiency data with the one got in a conventional sub-critical type steam power plant.

  • PDF

The Analysis of power of the Test Statistics for the Randomized Block Design (확률화 블록 실험계획 모형에서 검정 통계량들의 검정력 분석)

  • 배현웅;김제영
    • Journal of the military operations research society of Korea
    • /
    • v.27 no.2
    • /
    • pp.124-133
    • /
    • 2001
  • The purpose of this study is investigate the differences among parametric and nonparametric test statistics for the tree alternative hypothesis in the randomized block design. As the results, it was found that there was no large differences among parametric and nonparametric test statistics in power when the block sizes were larger, and Hollander's statistic had better power than other nonparametric test statistics. It is recommended that Hollander's test statistic is more useful method when we have no information about the distribution of population.

  • PDF

Development of Accurate Load Model for Detailed Power System Stability Analysis (전력계통 안정도 정밀해석을 위한 적정 부하모델 개발)

  • Park, S.W.;Kim, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.201-205
    • /
    • 2001
  • This paper presents the load modeling process and bus load models for KEPCO power system. At first, load devices commonly used in KEPCO power systems were selected, and tested for measuring the voltage and frequency sensitivity of active and reactive power. From this test, about 40 voltage and frequency dependent load models have been obtained. The bus load composition rate for KEPCO power system has been determined using the various recent surveys and papers in order to develop the load model for a power system bus. To verify the accuracy of developed bus load models, the field test for measuring active and reactive power according to artificial variation of the bus voltage was performed at 8 substations for spring summer, autumn, winter cases. With data of this seasonal field test, more reliable bus load models for KEPCO power systems were developed.

  • PDF

The Design of Lumped Constant Circuit for the Simulation of A Real 22.9 kV-y Distribution Line (22.9 kV-y 실긍장 배전선로 모의를 위한 집중정수회로의 설계)

  • Yun, Chul-Ho;Jeong, Yeong-Ho;Han, Yong-Huei
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1186-1188
    • /
    • 1999
  • When we perform the test related to the power distribution system such as artificial fault test, protective coordination test, distribution automation test in short length test line, Lumped Constant Circuit, a kind of variable impedance, should be attached to the test line in order to make it equivalent to a real line in length electrically. In this paper we designed the positive sequence and zero sequence Lumped Constant Circuit with optimized inductor and resister for the modification of long, 16km, distribution line, when they are attached to the short, 4km, distribution test line.

  • PDF

Power Analysis in Experimental Designs with t test Analysis (t 검정 실험 설계 시 표본 크기 결정에 대한 논의)

  • Kang, Jeong-Hee;Bang, Kyung-Sook;Ko, Sung-Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.15 no.1
    • /
    • pp.120-127
    • /
    • 2009
  • Purpose: In the literature power analysis in experimental studies is often executed and reported falsely. This descriptive study was done to promote the correct application of the Cohen(1988)'s power analysis method. Method: Articles of experimental studies from a nursing journal were selected and reviewed to examine the uses of and the reports on the power analysis process. Also, the appropriate power analysis process was discussed with an example of the most common experimental design, an independent two-group design with t test analysis plan. Result: Around half the experimental studies examined reported that they carried out power analysis. Cohen's method was the most frequently utilized but with accuracy in question. Conclusion: Power analysis to estimate sample size is the interplay between alpha, power, and effect size, and other factors in the case of t test analysis. Researchers should have a clear understanding of how to apply the Cohen's power analysis method so they do not produce poorly estimated sample sizes.

The Analysis of Anaerobic Power in Professional Female Basketball Players (여자 프로농구선수의 무산소성 파워 분석)

  • Chang Chung-Hoon;Nam Hyoung-Chun
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.172-180
    • /
    • 2002
  • The purpose of this paper was to make an analysis of anaerobic power in professional female basketball players using the Wingate Test Method with bicycle ergometer. Twenty-three subjects(age $21.6\pm2.8years$, body height $178.0\pm7.4cm$, body weight $70.3\pm7.4kg$) were selected from professional female basketball team whose careers were over 10years and participated in this investigation. Each subject peformed a Wingate anaerobic power test to determine total work, peak power, mean power, fatigue index and blood lactate concentration. The following were obtained from result data analysis; 1. The Total Work of athletes was a $1128.7\pm120.6watt$ 2. The Peak Power of athletes was a $449.5\pm53.1watt$ 3. The Mean Power of athletes was a $369.1\pm39.4watt$ 4. The Fatigue Index of athletes was a $33.5\pm6.9\%$ 5. The blood lactate concentration was $1.85\pm0.85mM/L$ at the normal state and $3.16\pm1.53mM/L$ at the after Wingate test. The blood lactate concentration was $6.96\pm0.81mM/L$ after 3 minute and $6.95\pm1.05mM/L$ after 5 minutes.

  • PDF