• 제목/요약/키워드: power normalization

검색결과 105건 처리시간 0.026초

자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발 (Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement)

  • 김재진;전정채
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.

방사전자파 내성시험(IEC801-3)용 측정시스템 및 S/W 개발에 관한 연구 (Development of Immuity Test System and Software Related with IEC801-3)

  • 김동일;김형근;배대환;민경찬
    • 한국항해학회지
    • /
    • 제19권3호
    • /
    • pp.29-34
    • /
    • 1995
  • IEC and CISPR have continuously endeavored the measurement method of Immunity Test as international unification, but not established yet. The main reason is that the measurement method and the normalization of threshold to obtain the complicated parameters for Immunity Test are difficult. Thus, the Immunity Test Setups are used differently according to the measured electromagnetic environments. This study developed an Immunity Test System and Algorithm for measurement software suitable for IEC801-3 Regulatons using ready-made amplifier, signal generator, and developes interconnecting interface board interacting with other appratus i.e., RF Switch, Power Meter, Field Sensor and Pre-amp. We are to develope an automated software using Top/Down and OOP(Object Oriented Programming) method.

  • PDF

DEFORMING PINCHED HYPERSURFACES OF THE HYPERBOLIC SPACE BY POWERS OF THE MEAN CURVATURE INTO SPHERES

  • Guo, Shunzi;Li, Guanghan;Wu, Chuanxi
    • 대한수학회지
    • /
    • 제53권4호
    • /
    • pp.737-767
    • /
    • 2016
  • This paper concerns closed hypersurfaces of dimension $n{\geq}2$ in the hyperbolic space ${\mathbb{H}}_{\kappa}^{n+1}$ of constant sectional curvature evolving in direction of its normal vector, where the speed equals a power ${\beta}{\geq}1$ of the mean curvature. The main result is that if the initial closed, weakly h-convex hypersurface satisfies that the ratio of the biggest and smallest principal curvature at everywhere is close enough to 1, depending only on n and ${\beta}$, then under the flow this is maintained, there exists a unique, smooth solution of the flow which converges to a single point in ${\mathbb{H}}_{\kappa}^{n+1}$ in a maximal finite time, and when rescaling appropriately, the evolving hypersurfaces exponential convergence to a unit geodesic sphere of ${\mathbb{H}}_{\kappa}^{n+1}$.

GENERATION OF AIRBORNE LIDAR INTENSITY IMAGE BY NORMALIZAING RANGE DIFFERENCES

  • Shin, Jung-Il;Yoon, Jong-Suk;Lee, Kyu-Sung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.504-507
    • /
    • 2006
  • Airborn Lidar technology has been applied to diverse applications with the advantages of accurate 3D information. Further, Lidar intensity, backscattered signal power, can provid us additional information regarding target's characteristics. Lidar intensity varies by the target reflectance, moisture condition, range, and viewing geometry. This study purposes to generate normalized airborne LiDAR intensity image considering those influential factors such as reflectance, range and geometric/topographic factors (scan angle, ground height, aspect, slope, local incidence angle: LIA). Laser points from one flight line were extracted to simplify the geometric conditions. Laser intensities of sample plots, selected by using a set of reference data and ground survey, werethen statistically analyzed with independent variables. Target reflectance, range between sensor and target, and surface slope were main factors to influence the laser intensity. Intensity of laser points was initially normalized by removing range effect only. However, microsite topographic factor, such as slope angle, was not normalized due to difficulty of automatic calculation.

  • PDF

전자파내성시험용 측정시스템의 개발에 관한 연구 (Development of Electromagnetic Wave Immunity Test system)

  • 정세모;김동일;배대환
    • 한국항해학회지
    • /
    • 제20권2호
    • /
    • pp.97-107
    • /
    • 1996
  • The method of Electromagnetic Wave Immunity Test is continuously endeavored by IEC and CISPR as international unification, but it has not been established yet. The main reason is why it is difficult to obtain the measurement method and normalization of threshold to find out the complicated parameters for Electromagnetic Wave immunity Test. So far, thus, the Electromagnetic Wave Immunity Test is carried out case by case as the electromagnetic environment, which is set up Electromagnetic Wave Immunity Test. This study has developed an algorithm and measurement software suitable for IEC1000-4 Regulations, where a ready-made Amplifier, and Signal Generator have been used and an interconnecting Interface Board has been constructed for connecting with the other apparatuses, i.e., RF Switch, Power Meter, Field Sensor, Pre-Amp., etc. Therefore, we have achieved the aim to develop an automated software using OOP method and the measurement system.

  • PDF

A Square Root Normalized LMS Algorithm for Adaptive Identification with Non-Stationary Inputs

  • Alouane Monia Turki-Hadj
    • Journal of Communications and Networks
    • /
    • 제9권1호
    • /
    • pp.18-27
    • /
    • 2007
  • The conventional normalized least mean square (NLMS) algorithm is the most widely used for adaptive identification within a non-stationary input context. The convergence of the NLMS algorithm is independent of environmental changes. However, its steady state performance is impaired during input sequences with low dynamics. In this paper, we propose a new NLMS algorithm which is, in the steady state, insensitive to the time variations of the input dynamics. The square soot (SR)-NLMS algorithm is based on a normalization of the LMS adaptive filter input by the Euclidean norm of the tap-input. The tap-input power of the SR-NLMS adaptive filter is then equal to one even during sequences with low dynamics. Therefore, the amplification of the observation noise power by the tap-input power is cancelled in the misadjustment time evolution. The harmful effect of the low dynamics input sequences, on the steady state performance of the LMS adaptive filter are then reduced. In addition, the square root normalized input is more stationary than the base input. Therefore, the robustness of LMS adaptive filter with respect to the input non stationarity is enhanced. A performance analysis of the first- and the second-order statistic behavior of the proposed SR-NLMS adaptive filter is carried out. In particular, an analytical expression of the step size ensuring stability and mean convergence is derived. In addition, the results of an experimental study demonstrating the good performance of the SR-NLMS algorithm are given. A comparison of these results with those obtained from a standard NLMS algorithm, is performed. It is shown that, within a non-stationary input context, the SR-NLMS algorithm exhibits better performance than the NLMS algorithm.

나카가미 페이딩 채널에서 딥러닝 기반 송신 전력 제어 기법을 이용하는 무선통신 시스템에 대한 성능 분석 (Performance Analysis of Wireless Communication Systems Using Deep Learning Based Transmit Power Control in Nakagami Fading Channels)

  • 김동현;김동연;이인호
    • 한국정보통신학회논문지
    • /
    • 제24권6호
    • /
    • pp.744-750
    • /
    • 2020
  • 본 논문에서는 무선통신 시스템의 주파수 효율과 에너지 효율을 개선하기 위하여 딥러닝 기반의 송신 전력 제어 기법을 제안한다. 무선통신 시스템에서 다수의 송수신기의 위치는 균일 분포를 따르고 송수신기 간 채널은 나카가미 페이딩 채널을 가정하여 제안하는 송신 전력 제어 기법에 대한 주파수 효율과 에너지 효율의 성능을 분석한다. 제안하는 송신 전력 제어 기법은 딥러닝 기반의 학습에서 주파수 효율과 에너지 효율을 개선하기 위하여 배치 정규화 기법을 이용한다. 시뮬레이션을 통해 송수신기의 위치 범위를 제한하는 지형적 크기와 나카가미 페이딩 지수에 대하여 제안하는 송신 전력 제어 기법과 기존의 송신 전력 제어 기법의 주파수 효율과 에너지 효율의 성능 결과를 비교한다. 성능 결과의 비교를 통해 제안하는 기법이 기존의 기법보다 우수한 성능을 제공함을 입증한다.

Monitoring observation of PG0934+013 using The Southern African Large Telescope

  • Park, Dawoo;Woo, Jong-Hak;Romero-Colmenero, Encarni;Crawford, Steven M.;Barth, Aaron J.;Pei, Liuyi
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.54-54
    • /
    • 2013
  • We performed spectroscopic and photometric monitoring observations of a QSO, PG0934+013 for a reverberation-mapping analysis, using the 9-m Southern African Large Telescope (SALT) for spectroscopy and the 2-m Faulkes Telescope North and the South for photometry. The monitoring campaign was carried out for 5 month between December 2012 to April 2013, providing 20 spectroscopic epochs and ~40 photometric epochs. Based on the obtained spectra, which typically have a signal-to-noise ratio to 30-60, we performed multicomponent decomposition using various components, i.e., power-law continuum, FeII emission complex, and broad and narrow emission lines, to properly measure the Hbeta line flux. After a flux normalization using [O III] 5007 line luminosity, we obtained a rms spectrum from all epochs, which shows clear variability of Hbeta line. We find that Hbeta line flux decreases by ~20% during the monitoring period while the continuum flux obtained from the aperture photometry based on the imaging data, shows similar variability. The current Hbeta light curve shows monotonic decrease and a reliable cross correlation analysis between Hbeta and continuum light is difficult. Nevertheless, we obtained a preliminary lag measurements as ~24 light days.

  • PDF

내부마케팅이 직무만족, 애호도, 기업성과에 미치는 영향 : 로지스틱회귀분석 방법을 이용 (Internal Marketing Approach to Internal Satisfaction, Loyalty and Organization Performance : Using Logistics Regression)

  • 손희영;강만수;박상규
    • 한국경영과학회지
    • /
    • 제39권3호
    • /
    • pp.117-131
    • /
    • 2014
  • As interests in the management of government-owned corporation rise, in these days, debt reduction and normalization of management of those companies have been proceeding under the lead of government. At this point, it is very important to seek internal marketing method for improvement of internal employees' satisfaction, loyalty and organization performance. This study analyzes impact of factors of internal marketing effect on organization satisfaction, loyalty and organization performance in the context of the domestic public companies, the Korea Electric Power Corporation (KEPCO) and the Korea Water Resources Corporation (K-WATER)'s employees empirically. There are some significant differences between the two publics. It is proved that delegation of the authority influences on internal satisfaction and organization performance in the case of KEPCO, and education and training influence on internal satisfaction and organization performance in the case of K-WATER. On the other hand, in the case of K-WATER, any internal marketing factors don't influence on loyalty. The results of this study show somewhat different characteristics depending on the characteristics of firm, however, it is expected that this study can be very useful in regards to similar public enterprises or businesses.

4각 안내덕트 루프형상에 의한 난류특성변화 수치해석 (A Numerical Study of the Turbulent Flow Characteristics in the Inlet Transition Square Duct Based on Roof Configuration)

  • 유근종;최훈기;최기림;신병주
    • 대한기계학회논문집B
    • /
    • 제33권7호
    • /
    • pp.541-551
    • /
    • 2009
  • Configuration of the inlet transition square duct (hereinafter referred to as "transition duct") for heat recovery steam generator (hereinafter referred to as "HRSG") in combined cycle power plant is limited by the construction type of HRSG and plant site condition. The main purpose of the present study is to analyze the effect of a variation in turbulent flow pattern by roof slop angle change of transition duct for horizontal HRSG, which is influencing heat flux in heat transfer structure to the finned tube bank. In this study, a computational fluid dynamics(CFD) is applied to predict turbulent flow pattern and comparisons are made to 1/12th scale cold model test data for verification. Re-normalization group theory (RNG) based k-$\epsilon$ turbulent model, which improves the accuracy for rapidly strained flow and swirling flow in comparison with standard k-$\epsilon$ model, is used for the results cited in this study. To reduce the amount of computer resources required for modeling the finned tube bank, a porous media model is used.