• Title/Summary/Keyword: power matching

Search Result 754, Processing Time 0.027 seconds

Improving Image Fingerprint Matching Accuracy Based on a Power Mask (파워마스크를 이용한 영상 핑거프린트 정합 성능 개선)

  • Seo, Jin Soo
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.1
    • /
    • pp.8-14
    • /
    • 2020
  • For a reliable fingerprinting system, improving fingerprint matching accuracy is crucial. In this paper, we try to improve a binary image fingerprint matching performance by utilizing auxiliary information, power mask, which is obtained while constructing fingerprint DB. The power mask is an expected robustness of each fingerprint bit. A caveat of the power mask is the increased storage cost of the fingerprint DB. This paper mitigates the problem by reducing the size of the power mask utilizing spatial correlation of an image. Experiments on a publicly-available image dataset confirmed that the power mask is effective in improving fingerprint matching accuracy.

Audio fingerprint matching based on a power weight (파워 가중치를 이용한 오디오 핑거프린트 정합)

  • Seo, Jin Soo;Kim, Junghyun;Kim, Hyemi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.6
    • /
    • pp.716-723
    • /
    • 2019
  • Fingerprint matching accuracy is essential in deploying a music search service. This paper deals with a method to improve fingerprint matching accuracy by utilizing an auxiliary information which is called power weight. Power weight is an expected robustness of each hash bit. While the previous power mask binarizes the expected robustness into strong and weak bits, the proposed method utilizes a real-valued function of the expected robustness as weights for fingerprint matching. As a countermeasure to the increased storage cost, we propose a compression method for the power weight which has strong temporal correlation. Experiments on the publicly-available music datasets confirmed that the proposed power weight is effective in improving fingerprint matching performance.

Design method of stable RF power amplifiers using 3dB coupled line (3dB coupled line을 이용한 안정한 RF전력증폭기 설계방법)

  • 김선욱;강원태;강충구;장익수
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.10
    • /
    • pp.24-31
    • /
    • 1997
  • A new design method of stable RF power amplifier using 3dB coupled line is proposed in this thiesis. The proposed method of broadband matching consist of resistive matching circuits at low frequency and lossless matching circuits at microwave band. This design method increase the stability of an amplifier and is suitable for interstage matching. When high power amplifier is designed using this method for PCS base transceiver station, the measured resutls show thst the gain of 18.5dB, and 9W (39.5dBm) output power. We use motorola's MRF6401 for medium power and MRF 6402 for large power and cascaded them.

  • PDF

Design of Low Noise Amplifier Utilizing Input and Inter Stage Matching Circuits (다양한 매칭 회로들을 활용한 저잡음 증폭기 설계 연구)

  • Jo, Sung-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.6
    • /
    • pp.853-856
    • /
    • 2021
  • In this paper, a low noise amplifier having high gain and low noise by using input and inter stage matching circuits has been designed. A current-reused two-stage common-source topology is adopted, which can obtain high gain and low power consumption. Deterioration of noise characteristics according to the source inductive degeneration matching is compensated by adopting additional matching circuits. Moreover trade-offs among noise, gain, linearity, impedance matching, and power dissipation have been considered. In this design, 0.18-mm CMOS process is employed for the simulation. The simulated results show that the designed low noise amplifier can provide high power gain and low noise characteristics.

Understanding of RF Impedance Matching System Using VI-Probe

  • Lee, Ji Ha;Park, Hyun Keun;Lee, Jungsoo;Hong, Snag Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The demand for stable plasma has been on the rise because of the increased delivery power amount in the chamber for improving productivity, and fast and accurate plasma impedance matching become a crucial performance measure for radio frequency (RF) power system in semiconductor manufacturing equipment. In this paper, the overall impedance matching was understood, and voltage and current values were extracted with voltage - current (VI) probe to measure plasma impedance in real-time. Actual matching data were analyzed to derive calibration coefficient for V and I measurements to understand the characteristics of VI probe, and we demonstrated the tendency of RF impedance matching according to changes in load impedance. This preliminary empirical research can contribute to fast RF matching as well as advanced equipment control for the next level of detailed investigation on embedded system based-RF matching controller.

Design and Implementation of L/Ku-band Broadband Power Detector using Schottky Diode (Schottky 다이오드를 이용한 Six-port용 L/Ku-band 광대역 Power detector 설계 제작)

  • Kim Young-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.615-618
    • /
    • 2006
  • The broadband power detector for direct- onversion Six-port output circuit was designed and implementaed in this paper. The power detector should linearly operated to produce the linear amplitude and phase signal fer input RF signal in required broadband. So, the power detector should be designed under conditions of matching circuit with low VSWR. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with matching circuit and isolator, respectively, were evaluated in the performances.

  • PDF

A study on application of aggregation method based on power flow matching technique and multi-variable control method to the power system (선로 조류 유지 기법에 근거한 계통축약 및 다변수 제어기법 적용 연구)

  • Lee, Byung-Ha;Oh, Min-Hyuk;Baek, Jung-Myoung
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.342-344
    • /
    • 2006
  • The modem enormous electric power system has made power system analysis much more complex and difficult. For effective analysis of the power system, model reduction and aggregation is required. In this paper, a new aggregation method is presented to aggregate the coherent generators in the large scale power system while matching the power flow. In order to demonstrate the effects of this aggregation method, it is applied to a small scale power system. A multi-variable control technique of $H_{\infty}$ control is also applied to enhance the dynamic stability of the aggregated power system.

  • PDF

Impedance Characteristics of N2 Plasma and Matching Circuit Design (질소 플라즈마의 임피이던스 특성 및 정합회로 설계)

  • 황기웅;김원규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.12
    • /
    • pp.560-566
    • /
    • 1986
  • In the design of an RF discharge system, the electrical equivalence of the gas discharge must be known. With this knowledge, one can design a suitable matching network for a maximum power transfer from the RF generator into the discharge. For this purpose, an experiment has been conducted in which the electrical impedance (conductance and capacitance) was determined as a function of power. In parallel with this, a detailed theoretical analysis has been done and the results are in accord with those of our experiment. Design equations are also given for a simple matching network, and a design example is presented to demonstrate its application. During the actual operation of an RF discharge system, however, it has been often observed that the reflected power tends to vary in small values due to the changes in the impedance of the system. This problem can be relieved by adding an automatic impedance matching circuit to the system and this paper presents such an automatic impedance matching network.

  • PDF

A Novel Impedance Matching Topology for Magnetically Coupled Wireless Power Transfer

  • Lee, Gunbok;Park, Wee Sang
    • International journal of advanced smart convergence
    • /
    • v.1 no.2
    • /
    • pp.16-19
    • /
    • 2012
  • A modified 4-coil magnetic resonance wireless power transfer (MRWPT) system is proposed. Four coils based on 2-coil system with additional two matching coils were used in this topology. When Tx-Rx distance is changed, the input impedance is changed. However, it can be adjusted by coil parameters of matching coils to maintain impedance matching for maximum efficiency. The equivalent circuit of MRWPT system was analyzed for both transmission function and optimum coupling coefficient of the matching coils. By using four spiral resonant coils, these design considerations was experimentally verified. The measured data agreed well with the calculated data and the transmission function of the proposed system was more efficient than that of conventional 2-coil system.

A Novel Online Multi-section Weighed Fault Matching and Detecting Algorithm Based on Wide-area Information

  • Tong, Xiaoyang;Lian, Wenchao;Wang, Hongbin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2118-2126
    • /
    • 2017
  • The large-scale power system blackouts have indicated that conventional protection relays that based on local signals cannot fit for modern power grids with complicated setting or heavily loaded-flow transfer. In order to accurately detect various faulted lines and improve the fault-tolerance of wide-area protection, a novel multi-section weighed fault matching and detecting algorithm is proposed. The real protection vector (RPV) and expected section protection vectors (ESPVs) for five fault sections are constructed respectively. The function of multi-section weighed fault matching is established to calculate the section fault matching degrees between RPV and five ESPVs. Then the fault degree of protected line based on five section fault degrees can be obtained. Two fault detecting criterions are given to support the higher accuracy rate of detecting fault. With the enumerating method, the simulation tests illustrate the correctness and fault-tolerance of proposed algorithm. It can reach the target of 100% accuracy rate under 5 bits error of wide-area protections. The influence factors of fault-tolerance are analyzed, which include the choosing of wide-area protections, as well as the topological structures of power grid and fault threshold.