• Title/Summary/Keyword: power line environment

Search Result 359, Processing Time 0.026 seconds

Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier

  • Yoo, Sun-K.
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.5
    • /
    • pp.601-605
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

LOS and NLOS Path-loss Characteristics at 3.4, 5.3, and 6.4 ㎓ in an Urban Environment (3.4, 5.3, 6.4 ㎓ 대역 신호의 가시 및 비가시 구간에서의 경로손실 특성)

  • 조한신;박병성;육종관;박한규;이정수
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.127-131
    • /
    • 2002
  • This paper presents the a measured path-loss characteristics in urban line-of-sight(LOS) and non line-of-sight(NLOS) environments for 3.4, 5.3, and 6.4 ㎓ band signals. A two-ray model is applied to analyse the path-loss characteristics in LOS areas. In LOS areas, an empirical break point, whose distance is shorter than a theorical break point, is founded. Further, a sudden power level drop occurs at a transition point from LOS region to NLOS area and different path-loss exponents are occured various cases. The power level drop due to comer loss and path-loss exponents both increase as the distance between the transmitter and the corner increases.

  • PDF

Remote Dimming Control System Development of LED Street Light using PLC (전력선 통신을 이용한 LED 가로등의 원격조도제어 시스템 개발)

  • Kim, Ki-Nam;Yoo, Jin-Wan;Park, Jong-Yeon
    • Journal of Industrial Technology
    • /
    • v.30 no.B
    • /
    • pp.113-118
    • /
    • 2010
  • In this paper, We proposed remote dimming control system for Light Emitting Diode(LED) street light using Power Line Communication(PLC). LED will be used widly by indoor or outdoor lighting because of semi-permanent life and environment restriction. For energy saving of street light, the dimming control system is very necessary and the PLC is a very efficient technique. Thus, in this paper we proposed the remote dimming control system for LED street light using PLC. A performance of the proposed system was validated by experimental results.

  • PDF

Analysis of characteristics for clamping voltage fellowing the application of element for preventing the short circuit of Metal Oxide Varistors for ZnO (ZnO 계열의 금속산화물 바리스터의 단락 방지용 소자 적용에 따른 제한전압 특성 분석)

  • Jeong, Tae-Hoon;Choi, Sung-Wook;Jeong, Je-Seon;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1531-1532
    • /
    • 2006
  • Recently, the natural environment changes drastically, and the frequency of occurrence for lightning has gradually been increased. Such lightning delivers high volume of energy along the power line and communication line to the equipment in use. The high volume of energy arising from the lightning surge develops in fast velocity to destroy the facilities in power source and many other facilities in operation in sequential destruction with vast energy. In this thesis, the analysis on the change of clamping voltage characteristics by the contact resistance and lead inductance by using several case studies through the application of element for preventing the short circuit of Metal Oxide Varistor for ZnO.

  • PDF

Improvement of the Conductor Temperature Calculation Algorithm for Calculating the Allowable Current in the Underground Channel (지중관로에서의 실제 허용전류 산출을 위한 도체온도 계산 알고리즘 개선에 관한 연구)

  • Lee, Hyang-Beom;Lee, Byung-Chul;Kim, Jung-Hoon;Nam, Yong-Hyun;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.352-357
    • /
    • 2018
  • In this paper, the improvement of the conductor temperature calculation algorithm is studied. The allowable current of the underground transmission line is determined by the conductor temperature limit. Usually to calculate the allowable current limit, the conductor temperature is assumed in the most worst environment condition. It is possible to increase the transmission capacity if the actual burial environment is considered. Therefore, in this paper an algorithm is proposed to calculate the conductor temperature by distinguishing two area of a underground transmission line condition - the manhole where the temperature sensor can be installed and the underground transmission line in which the temperature sensor can not be installed easily. When calculating the conductor temperature by the underground line in the pipeline, the existing standard describes each environment as a single soil heat resistance and one ambient temperature. In order to compensate this situation, thermal resistance model that can take into consideration the ground surface temperature and under ground temperature is proposed. It is shown that the accuracy of the proposed model is increased compared with the existing standard calculation result.

A Study on the Power and Smoke Characteristics for the Intake System Improvement using Air Conditioning System in a Diesel Vehicle (디젤 자동차의 에어컨 사용시 흡기계통 개선에 따른 출력 및 매연 특성에 관한 연구)

  • Youn, Y.C.;Kwon, K.R.;Pyeon, H.
    • Journal of Power System Engineering
    • /
    • v.15 no.6
    • /
    • pp.11-15
    • /
    • 2011
  • This study investigated the symptoms of the a reduction in output while driving on the road, or increasing of fumer out exhaust gas on inclined road while working air-conditioner in summer. Notice how the experiment in 2010, the Ministry of Environment(Chapter No. 2010-46), and how the vehicle emissions inspection was carried out. 2500cc Diesel cars used in the study were used and compare to output of engine, exhaust gas, inhalation temperature measurement Inhalation of cold air has not been supplied to all agencies when comparing the results when cold air intake temperature of the supply air-conditioning switch range control from 1 to 4, the temperature drops $98^{\circ}C$ to $78^{\circ}C$. At the momentum of switch level 4, output from 63ps to 66ps after the connection has increased 9.6 percent, the highest concentration of exhaust emissions were reduced by 42.8%. This research can contribute in part to the reduction of exhaust directly supply into the cooling air intake line, doing the output of diesel cars in the summer. In addition, construction equipment and machinery that are currently being used excluding the engine's intercooler cooling of the supply line via a separate output in the summer and help reduce exhaust emissions is expected.

The Study on the Efficient HVDC Capacity Considering Extremely Low Probability of 765kV Double Circuit Transmission Lines Trip

  • Moon, Bong-Soo;Ko, Boyung;Choi, Jin-San
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1046-1052
    • /
    • 2017
  • The load on the power grid of South Korea is expected to grow continuously until the late 2020s, and it is necessary to increase the transfer capacity from the Eastern grid to the Seoul-Gyeonggi region by reinforcing the transmission network for the electric power system to remain stable. To this end, the grid reinforcement by two bipole LCC HVDC transmission systems have been considered on account of the public acceptability and high growth of the fault current level, even though an additional 765kV system construction is more economical. Since the probability of the existing 765kV double circuit transmission line trip is extremely low, a dynamic simulation study was carried out to estimate the efficient HVDC capacity able to stabilize the transient stability by utilizing the HVDC overload capability. This paper suggests the application plan to reduce the HVDC construction capacity with ensuring the transient stability during the 765kV line trip.

A study on the application of TALK-BACK system in a radio communication environment (토크백 시스템 무선통신 적용방안 연구)

  • Yeo, Yong-Joo;Yoon, In-Young;Nam, Joung-In;Choi, Yoon-Seog
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1294-1302
    • /
    • 2008
  • Talk-Back systems comprised of master-equipment at the control room and slave-equipment at turnouts refer to the intercommunication facilities that optimize mutual communication between maintenance staff on trackside and the control room to facilitate quickness and accuracy of train operation control and its maintenance within depot and on mainlines with turnouts for direction switching of the trains in operation. The weakness lies in additional maintenance costs of cables since the Talk-Back system installed on line 1 along with line 2-4 has a profound effect on the voice quality leading to the attenuation and crosstalk of the system due to the deterioration of cables and environmental factors. This paper discusses the Talk-Back system in a radio communication environment with the application of RF(Radio Frequency) communication system from the wire communication system by cables to ameliorate these problems, and deals with the energy saving environmentally friendly facilities in consideration of replacing power section at salve-equipment with solar batteries benefitting the system in light of energy consumption.

  • PDF

Real-Time Haptic Rendering for Tele-operation with Varying Communication Time Delay (가변적인 통신지연시간을 갖는 원격 작업 환경을 위한 실시간 햅틱 렌더링)

  • Lee, K.;Chung, S.Y.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.71-82
    • /
    • 2009
  • This paper presents a real-time haptic rendering method for a realistic force feedback in a remote environment with varying communication time-delay. The remote environment is assumed as a virtual environment based on a computer graphics, for example, on-line shopping mall, internet game and cyber-education. The properties of a virtual object such as stiffness and viscosity are assumed to be unknown because they are changed according to the contact position and/or a penetrated depth into the object. The DARMAX model based output estimator is proposed to trace the correct impedance of the virtual object in real-time. The output estimator is developed on the input-output relationship. It can trace the varying impedance in real-time by virtue of P-matrix resetting algorithm. And the estimator can trace the correct impedance by using a white noise that prevents the biased input-output information. Realistic output forces are generated in real-time, by using the inputs and the estimated impedance, even though the communication time delay and the impedance of the virtual object are unknown and changed. The generated forces trace the analytical forces computed from the virtual model of the remote environment. Performance is demonstrated by experiments with a 1-dof haptic device and a spring-damper-based virtual model.

  • PDF

Power System Education System using 3-Dimensional Graphic Animation (3차원 그래픽 애니메이션을 이용한 전력계통 교육시스템)

  • Park, In-Kwon;Won, Jong-Ryul;Lee, Jin;Yoon, Yong-Beum
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.6
    • /
    • pp.593-601
    • /
    • 2001
  • This paper presents an efficient system for power system education using 3-D computer graphics animation in the PC environment. Several power system phenomena are simulated using Real-Time Digital Simulator. Results are transmitted through on-line communication line to PC for graphic animation, and simulated in the 3-D graphics animation. It can immediately reflect user control input and re-simulated this result. The proposed method was tested on both the sub-synchronous resonance phenomena and multi-bus system. It is expected that the proposed method would be helpful for the operator training as well as power system education.

  • PDF