• Title/Summary/Keyword: power line communication technology

Search Result 296, Processing Time 0.028 seconds

A Resonance Power Combining Technique Using CRLH-Transmission Line (CRLH 전송 선로를 이용한 공진 기법의 전력 결합 기술)

  • Kim, Ell-Kou;Kim, Young;Kwon, Sang-Keun;Yoon, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.673-679
    • /
    • 2009
  • This paper proposes a resonance power-combining technique using CRLH-transmission line. The circuits using proposed technique consist of the parallel capacitances and transmission lines to satisfy matching conditions and to combine power of amplifiers. The CRLH(Composite Right/Lefi-Handed) transmission lines are used to reduce the circuit size. As a result, the power combining amplifier using proposed techniques is measured that a gain is equal and the output power is increased about 2.2 dB higher than the single amplifier. Also, a size of amplifier is 78.3 % smaller than the conventional amplifier using RH transmission line.

A Study on Short-Range Wireless Communication System Development Using LED Based on Power Line Communication (전력선통신기반 LED를 이용한 단거리 무선통신 시스템 개발에 관한 연구)

  • Yun, Ji-Hun;Kim, Yong-Kab
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.1
    • /
    • pp.19-23
    • /
    • 2010
  • This study is to develop power line communication and short-range wireless communication system using LED. I will create optical receiver and transmitter using LED and optical sensor and connectors for display device and communication in receiver and transmitter were created. Experiment method is to signal and waveform through oscilloscope date from optical sensor after chosen a highly efficient LED. In addition, reception and transmitter of smoothly data using visible light communication program were checked. I will compliment problems through this experiment and constantly study, improve on power loss.

  • PDF

The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway (전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성)

  • Kim, Jae-Moon;Ahn, Seung-Ho;Kim, Yang-Su;Kim, Chul-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

Visible Light Communication Systems for Sensor Networks Using Synchronizing Pulse Transmission Through the Power Lines (전력선 전송 동기신호를 이용한 센서 네트워크용 가시광통신시스템)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.212-218
    • /
    • 2013
  • In this paper, we introduce a new method to reduce the inter-channel crosstalk in visible light communication (VLC) systems using the synchronizing pulses transmitted through the power lines. Synchronizing pulses are simultaneously transmitted to multiple VLC transmitters and receivers through the 220V power line. Each VLC transmitter modulates an LED and each VLC receiver demodulates the signal light in the time slot that is allocated with reference to the synchronizing pulses. This method is very simple and effective to prevent the inter-channel crosstalk in VLC systems for sensor networks because every VLC system can easily get the synchronizing pulses from the nearby power line.

A study for chirp signal method & system implementation in the PLC modem with low speed (저속 PLC 모뎀에서의 Chirp 신호 방식과 시스템 구현에 관한 연구)

  • Jeong, Young-Hwa;Sang-Gun Lee
    • The Journal of Information Technology
    • /
    • v.7 no.3
    • /
    • pp.37-45
    • /
    • 2004
  • The representative communication method which is applied in the low-speed power line communication modem with 60bps is single carrier method. It has been used mainly for the control. The single carrier method is very sensitive to a power line communication channel environment. Specially, the severe attenuation of the transmission signal according to the notch characteristics of channel becomes the main cause of communication error. Domestic power line channel environment has this notable feature. In this paper, we implemented the low-speed power line communication system which used the chirp signal method to be strong in notch and noise characteristics. In this research, we proposed the method which transmits 1- '1 Unit symbol Chirp signal' with a 100${\mu}s$ time within 1ms for 1 bit. Also it applied for the Convolution code for an error correction and the Manchester code for a collision perception and an error detection. It used the method which uses the bit correlator for signal detection in the receiver parts. We confirmed that the communication method of the chirp method has a excellent performance compared to single carrier methods with a result of experiment of the low-speed power line communication system with the 60bps.

  • PDF

Data Transmission over Power Line with Lightning Protection Devices

  • Kim, Sungeon;Jeon, Taehyun
    • International journal of advanced smart convergence
    • /
    • v.2 no.1
    • /
    • pp.27-29
    • /
    • 2013
  • This paper discusses comparative analysis of the effects of surge protection devices (SPD) upon the power line communication channels. The quality of the data transmission channel is measured based on the data rate for the various channel parameters which include channel length and application method of the lightning protection device. The performance measurements are also carried out for various lengths of the communication channel. Experiment results show that specific combination of SPDs applied in the network causes severe degradation of the channel quality which is associated with the combination of grade levels and channel lengths.

Analysis of the Competitiveness of Broadband over Power Line Communication in Korea

  • Jeong, Gi-Cheol;Koh, Dae-Young;Lee, Jong-Su
    • ETRI Journal
    • /
    • v.30 no.3
    • /
    • pp.469-479
    • /
    • 2008
  • This study analyzes factors affecting the competitiveness of broadband over power line communication (BPLC) and predicts demand for the service, based on quantitative information about consumer preferences drawn from a survey of Korean consumers. Findings from the estimation suggest that, although consumers value some beneficial features of BPLC, to be competitive the speed and stability of its data transmission needs to be improved. Moreover, on the basis of a market simulation, we expect BPLC to occupy only a small portion of Korea's Internet access market in the future, a finding we expect would hold true for other developed countries whose Internet access markets are already mature.

  • PDF

Robust Approach for Channel Estimation in Power Line Communication

  • Huang, Jiyan;Wang, Peng;Wan, Qun
    • Journal of Communications and Networks
    • /
    • v.14 no.3
    • /
    • pp.237-242
    • /
    • 2012
  • One of the major problems for accurate channel estimation in power line communication systems is impulsive noise. Traditional channel estimation algorithms are based on the assumption of Gaussian noise, or the need to locate the positions of impulsive noise. The algorithms may lose optimality when impulsive noise exists in the channel, or if the location estimation of impulsive noise is inaccurate. In the present paper, an effective channel estimation algorithm based on a robust cost function is proposed to mitigate impulsive noise. The proposed method can provide a closed-form solution, and the application of robust estimation theory enables the proposed method to be free from localization of impulsive noise and thus can guarantee that the proposed method has better performance. Simulations verified the proposed algorithm.

Investigations on IT/ET and IT/BT Convergence Technology Using Power Line Communications (Power Line Communications을 이용한 IT/ET, IT/BT 컨버젼스 기술에 관한 연구)

  • Park, Mi-Kyoung;Huh, Young;Oh, Sang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.250-252
    • /
    • 2006
  • Due to enhanced high IT (information technology) development, IT-based technology convergences such as IT/ET(electric technology), IT/BT(biology technology) and IT/NT(nano technology) are actively merging trend and their applications spread wide. In this paper PLC (power line communication), one of the merging IT, is investigated as one of the potential IT candidates for IT/ET and IT/BT convergence technology for DLC (direct load control) or bio-medical engineering such as ubiquitous health cares or D2H2 (distributed diagnosis and home health care).

  • PDF

A Method for Fault detecting on Power Transmission Network by use of M-sequence Correlation

  • Nishiyama, Eiji;Kuwanami, Kenshi;Owaki, Kosuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2570-2575
    • /
    • 2003
  • Monitoring a power transmission line is significant for power electric companies. In this paper, we propose a new method for detecting an fault point of power transmission line by use of M-sequence correlation technique. In this method, detecting signal is used as one or plural M-sequences ( same characteristic polynomial, including normal and reverse mark, synchronized ). In receiving point, we make same sequence with the input one and take crosscorrelation function between M-sequence and the received signal. We can see transfer fanctions of plural paths between inputs and a output taps separated from different of delay times on the crosscorrelation function, and from these transfer fanctions, so we compare them when fault occurred with in usual.

  • PDF