• Title/Summary/Keyword: power image

Search Result 1,796, Processing Time 0.035 seconds

Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members

  • Woo, Sangkyun;Chu, Inyeop;Youn, Byongdon;Kim, Kijung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.293-298
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.

Histogram Learning-based Solar Power Plant Failure Reading System (히스토그램 학습 기반 태양광발전소 고장 판독 시스템)

  • Youm, SungKwan;Shin, Kwang-Seong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.572-573
    • /
    • 2021
  • By optimizing the development of IoT-type thermal image-based photovoltaic fault detection equipment and interworking with drones using a drone with an intelligent path movement function, real-time analysis of the acquired image data facilitates fault reading of solar power plants. , design a system that can read out the failure of a solar panel using the image subtraction analysis technique and the presentation of the basic technology that can improve the power generation rate of the solar power plant and make an efficient maintenance model.

  • PDF

Regional Contrast Enhancement for Local Dimming Backlight on Small-sized Mobile Display

  • Chung, Jin-Young;Kim, Ki-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.972-974
    • /
    • 2009
  • This paper presents smart regional contrast enhancement technique of partitioned image for local dimming backlight on small-sized mobile display to reach two goals. One is to save the power consumption, and the other to improve contrast ratio of display image. Recently new advanced method is proposed, named local dimming method, that backlight LED is positioned on backside of the display panel. So it is important to partition an image by sub blocks and then post-processing independantly. This means regional contrast enhancement. After partitioning, we compare the mean luminance(Y) value of each sub-block image with the one of original whole image. If some blocks have the mean value lower than the one of whole image, they are processed with the proposed method and others are bypassed. Simultaneously the information of the processed blocks are transferred to BLC(Backlight LED Controller). And then the supply current of each backlight LED is reduced to realize the contrast ratio enhancement and at the same time to power consumption reduction. In addition, we verify this proposed method is free from blocking artifacts.

  • PDF

A Calculation of Superconductor Bearing Characteristics (초전도 베어링 특성 계산)

  • 윤희중;한영희;한상철;정년호;김경진;박병삼;오제명;성태현
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.141-143
    • /
    • 2004
  • For designing a flywheel system using superconductor, it is necessary to understand the basic characteristics of the classical superconductor bearing. It is difficult to expect the characteristics of superconductor bearings using models that have been introduced up to now. In the "Frozen image" concept, the farce between the permanent magnet and the superconductor can be divided into two forces between permanent magnet and two imaginary magnets in the superconductor; one represents attraction farce and the other represents a repulsion force. We calculated the characteristics of two superconductor bearings, such as an axial, the radial stiffness and the levitation force. This calculation method was very helpful to expect the characteristics of the superconductor bearings. Using this model, we established the optimum condition for the superconductor bearing.r bearing.

  • PDF

The study of plant application at flame management system with flame monitoring for pulverized coal firing boiler of thermal power plant (발전용 미분탄 연소 보일러 화염감시장치의 현장적용에 관한 연구)

  • Baeg, Seung-Yeob;Kim, Seung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.535-537
    • /
    • 2004
  • The flame image processing and it's analysis system has been developed for optimal coal firing of thermal power plant, especially for reducing NOx and safe operations. We aimed at gaining the relationship between burner flame image, emissions of NOx and LOI(Loss on ignition) in furnace by utilizing the flame image processing methods. And the relationship determines quantitatively the conditions of combustion on the individual burners. The test was conducted on Samchonpo thermal power plant #4 unit(560MW) of KOSEP which has 24 burners. The system simplified the burner adjustment works in accordance with the real time trending of flame behavior like NOx profiles and unburned carbon profiles for individual burners. But, This kind of conventional method increases the cost as the number of burner are increased. Also there is a difficulty to measure exhausted gas of each burner because of measurement errors. This paper intends to propose the useful "Flame Monitoring System" that can find Low NOX and LOI at the upper furnace and to compare with the conventional System.

  • PDF

A Development of Image Transfer Remote Maintenance Monitoring System for Hand Held Device (휴대용 화상전송 원격정비 감시시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.276-284
    • /
    • 2009
  • In this paper, we develop the image transfer remote maintenance monitoring system for hand held device which can compensate defects of human mistake. The human mistakes always happen when the worker communicate information each other to check and maintenance the equipment of the power plant under bad circumstance such as small place and long distance in power plant. A worker couldn't converse with other when in noisy place like Power plant. So, we make some hand device for handy size and able to converse in noisy place. The developed system can have improvement of productivity through increasing plant operation time. And developed system is composed of advanced H/W(hard ware) system and S/W(soft ware)system. The H/W system consist of media server unit, communication equipment with hand held device, portable camera, mike and head set. The advanced s/w system consist of data base system, client pc(personal computer) real time monitoring system which has server GUI(graphic user interface) program, wireless monitoring program and wire ethernet communication program. The client GUI program is composed of total solution program as pc camera program, and phonetic conversation program etc.. We analyzed the required items and investigated applicable part in the image transfer remote maintenance monitoring system with hand held device. Also we investigated linkage of communication protocol for developed prototype, developed software tool of two-way communication and realtime recording skill of voice with image. We confirmed the efficiency by the field test in preventive maintenance of plant power.

Improved Performance Evaluation Method for EUT in Power Frequency Magnetic Field Immunity Test (전원주파수 자계 내성시험의 개선된 EUT 성능평가방법)

  • 정기범;최재훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.796-802
    • /
    • 2003
  • In this paper, an improved EUT(Equipment Under Test) evaluation method using image monitor for power frequency magnetic field immunity test was proposed and development of an automated real time image monitoring program was described. The proposed power frequence magnetic field immunity test detects automatically the change between the affected and unaffected image of EUT under the influence of electromagnetic wave. The proposed method for real time decision supplements shortcomings of the currently used method which is subjective to tester´s decision by ensuring the repeatability of the test. The change detection of EUT image provides a possibility of the immunity decision for PC monitors. In addition, the method to draw quantitative value in EUT immunity decision is suggested in accordance with the international standards and domestic trends.

Image Analysis by CNN Technique for Maintenance of Porcelain Insulator (자기애자의 유지 관리를 위한 CNN 기법을 이용한 이미지 분석)

  • Choi, In-Hyuk;Shin, Koo-Yong;Koo, Ja-Bin;Son, Ju-Am;Lim, Dae-Yeon;Oh, Tae-Keun;Yoon, Young-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.239-244
    • /
    • 2020
  • This study examines the feasibility of the image deep learning method using convolution neural networks (CNNs) to maintain a porcelain insulator. Data augmentation is performed to prevent over-fitting, and the classification performance is evaluated by training the age, material, region, and pollution level of the insulator using image data in which the background and labelling are removed. Based on the results, it was difficult to predict the age, but it was possible to classify 76% of the materials, 60% of the pollution level, and more than 90% of the regions. From the results of this study, we identified the potential and limitations of the CNN classification for the four groups currently classified. However, it was possible to detect discoloration of the porcelain insulator resulting from physical, chemical, and climatic factors. Based on this, it will be possible to estimate the corrosion of the cap and discoloration of the porcelain caused by environmental deterioration, abnormal voltage, and lightning.

A Research of Power-Efficient Driving Scheme for Auto-Focus on Image Sensor Module (이미지 센서 모듈을 위한 자동-초점 기능의 전력-효율적인 구동 방법에 대한 연구)

  • Cha, Sang-Hyun;Park, Chan-Woo;Lee, Yuen-Joong;Hwang, Byoung-Won;Kwon, Oh-Jo;Park, Deuk-Hee;Kwon, Kyoung-Soo;Lee, Jae-Shin;Hwang, Shin-Hwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.12
    • /
    • pp.1197-1202
    • /
    • 2009
  • We present a power-efficient driving scheme that consists of piezoelectric actuator and driver IC for AF (Auto-Focus) on ISM (Image Sensor Module). The piezoelectric actuator is more power-efficient than conventional voice coil motor actuator. And high power-efficiency driver IC is designed. So the proposed driving scheme using designed piezoelectric actuator and driver IC is more close to recent trend of green IT. The diver IC should guarantee fast and accurate performance. So, the optimum driving method and high accurate frequency synthesizer are proposed. The die area of designed driver IC is $2.0{\times}1.6mm^2$ and power consumption is 2.8mW.

Study on the Multi-measuring Method for Evaluation of Internal Leak of Power Plant Valve (발전용 밸브누설 평가를 위한 다중계측 연구)

  • Lee, S.G.;Park, S.K.;Park, J.H.;Kim, K.H.;Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.35-40
    • /
    • 2007
  • Leak would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leak at present are analysis of ${\Delta}T$, AE(Acoustic Emission) analysis, and thermal image. The result for test of secondary system in nuclear power plant Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leak is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So we think that using the Multi-Measuring method is more sound judgment than single-measuring method.

  • PDF