• Title/Summary/Keyword: power distribution

Search Result 6,652, Processing Time 0.03 seconds

Criteria and Limitations for Power Rails Merging in a Power Distribution Network Design

  • Chew, Li Wern
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.4
    • /
    • pp.41-45
    • /
    • 2013
  • Modern electronic devices such as tablets and smartphones are getting more powerful and efficient. The demand in feature sets, functionality and usability increase exponentially and this has posed a great challenge to the design of a power distribution network (PDN). Power rails merging is a popular option used today in a PDN design as numerous power rails are no longer feasible due to form factor limitation and cost constraint. In this paper, the criteria and limitations for power rails merging are discussed. Despite having all the advantages such as pin count reduction, decoupling capacitors sharing, lower impedance and cost saving, power rails merging can however, introduce coupling noise to the system. In view of this, a PDN design with power rails merging that fulfills design recommendations and specifications such as noise target, power well placement, voltage supply values as well as power supply quadrant assignment is extremely important.

Properties of the Poisson-power Function Distribution

  • Kim, Joo-Hwan
    • Communications for Statistical Applications and Methods
    • /
    • v.2 no.2
    • /
    • pp.166-175
    • /
    • 1995
  • When a neutral particle beam(NPB) aimed at the object and receive a small number of neutron signals at the detector without any errors, it obeys Poisson law. Under the two assumptions that neutral particle scattering distribution and aiming errors have a circular Gaussian distributions that neutral particle scattering distribution and aiming errors have a circular Gaussian distribution respectively, an exact probability distribution of neutral particles vecomes a Poisson-power function distribution. We study and prove some properties, such as limiting distribution, unimodality, stochastical ordering, computational recursion fornula, of this distribution. We also prove monotone likelihood ratio(MLR) property of this distribution. Its MLR property can be used to find a criteria for the hypothesis testing problem.

  • PDF

Current Limiting Characteristics due to Application Location of a Superconducting Fault Current Limiter in a Simulated Power Distribution System (모의배전계통에 초전도한류기의 도입위치에 따른 전류제한 특성)

  • You, Il-Kyoung;Kim, Jin-Seok;Kim, Myoung-Hoo;Kim, Jae-Chul;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.90-95
    • /
    • 2009
  • The application of a large power transformer into a power distribution system was inevitable due to the increase of power demand and distributed generation. However, the decrease of the power transformer‘s impedance causes the short-circuit current of the power distribution system to increase and thus, the higher short-circuit current exceeds the cut-off ratings of the protective devices such as a circuit breaker. To solve these problems, several countermeasures have been proposed to protect the power system effectively from the higher fault current and the superconducting fault current limiter (SFCL) has been expected to be the promising countermeasure. However, the current limiting effect of SFCL including its bus voltage drop compensation depends on SFCL's application location in a distributed power system. In this paper, the current limiting and the bus-voltage drop compensating characteristics of the SFCL applied into a power distribution system were studied. In addition, the quench and the recovery characteristics of the SFCLs in each location of the power distribution system were compared each other.

Calculation of Distribution Network Charging for DG Embedded Distribution System (분산전원 투입을 고려한 배전망 이용요금 산정에 관한 연구)

  • Hwang, Seok-Hyun;Kim, Mun-Kyeom;Park, Jong-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.513-521
    • /
    • 2012
  • With the advent of smart grid, distribution network charges have been one of keystones of ongoing deregulation and privatization in power industries. This paper proposes a new charging methodology to allocate the existing distribution network cost with an aim of reflecting the true cost and benefit of network customers, especially of distribution generator (DG). The proposed charging methodology separates distribution network costs due to the respective real and reactive power flows. The costs are then allocated to network users according to each charge for the actual line capacity used and available capacity. This distribution network charging model is able to provide the economic signals to reward network users who are contributing to better power factors, while penalizing customers who worsen power factors. The proposed method is shown on IEEE 37 bus system for distribution network, and then the results are validated through the comparison with the MW-Miles and MVA-Miles methods. The charges derived from the proposed method can provide appropriate incentives/penalties to network customers to behave in a manner leading to a better network condition.

Study on Capacity Design of Active Phase Controller for Distribution Line Reconfiguration (배전선로 재구성을 위한 능동위상제어기의 용량 선정 연구)

  • Jeong, Da-Woom;Kim, Soo-Yeon;Park, Sung-Jun;Kim, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.369-375
    • /
    • 2020
  • Distribution energy resources have been increasing in recent years. However, output power is limited for distribution network stability. This study proposes an active distribution network that can reconfigure distribution lines by using an active phase controller. A conventional distribution network has a fixed structure, whereas an active distribution network has a variable structure. Therefore, the latter can increase the output power of distribution energy resources and decrease the overload of distribution line facilities. An active phase controller has two operation modes for minimizing circulating current during dynamic reconfiguration. In this study, voltage and current control algorithms are proposed for active phase controllers. The simulation of the proposed methods for active phase controllers is performed using PSIM software.

Analysis on Recloser-Fuse Coordination in a Power Distribution System linked Small Scale Cogeneration System with Superconducting Fault Current Limiter (소형 열병합발전 시스템이 연계된 배전계통에 초전도 전류제한기 적용시 리클로져-퓨즈 협조 분석)

  • Kim, Myoung-Hoo;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Lee, Joon-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.499-505
    • /
    • 2010
  • This paper analyzed that the coordination of recloser-fuse when a superconducting fault current limiter (SFCL) is installed to a power distribution system linked small scale cogeneration system. As a rule, the recloser to properly protect against both permanent and temporary fault is installed to upstream of fuse. Therefore, in a power distribution system linked small scale cogeneration system, the fault current is increased by adding fault current of small scale Cogeneration system when a permanent fault occurs, and the fuse could melt during the first fast operation of the recloser because of more sufficient heat from the increased current. However, when SFCLs are applied into a power distribution system linked small scale cogeneration system, the coordination of recloser-fuse could be accomplished due to decreased fault current as the effect of the impedance value of the SFCL. Therefore, to solve these problems, we analysed the operation of recloser-fuse coordination in a power distribution system linked small scale cogeneration system with SFCL using PSCAD/EMTDC.

The Simplified Economic Evaluation of Extra-High Voltage Distribution System in the Large Apartment Complex (대단위 아파트에서 특고압 배전시스템의 경제성 평가)

  • Yun, Man-Soo;Chung, Chan-Soo;Park, Hyung-Joon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.117-124
    • /
    • 2007
  • This paper is about the Extra-High voltage distribution system in the customer's area. The power loss in the distribution system in the customer's area is disregarded and rarely managed so far. But, economically, this loss is not small quality to ignore. So, in this paper, we calculate the power loss of the Extra-High voltage distribution system in the customer's area by changing the locations of power transformer and other power facilities to decrease power loss in decreased secondary line length. And we also show the payback time of the proposed Extra-High voltage distribution system in the customer's area by simplified calculations.

Coordinated Voltage Control Scheme for Multi-Terminal Low-Voltage DC Distribution System

  • Trinh, Phi Hai;Chung, Il-Yop;Kim, Taehoon;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1459-1473
    • /
    • 2018
  • This paper focuses on voltage control schemes for multi-terminal low-voltage direct current (LVDC) distribution systems. In a multi-terminal LVDC distribution system, there can be multiple AC/DC converters that connect the LVDC distribution system to the AC grids. This configuration can provide enhanced reliability, grid-supporting functionality, and higher efficiency. The main applications of multi-terminal LVDC distribution systems include flexible power exchange between multiple power grids and integration of distributed energy resources (DERs) using DC voltages such as photovoltaics (PVs) and battery energy storage systems (BESSs). In multi-terminal LVDC distribution systems, voltage regulation is one of the most important issues for maintaining the electric power balance between demand and supply and providing high power quality to end customers. This paper focuses on a voltage control method for multi-terminal LVDC distribution system that can efficiently coordinate multiple control units, such as AC/DC converters, PVs and BESSs. In this paper, a control hierarchy is defined for undervoltage (UV) and overvoltage (OV) problems in LVDC distribution systems based on the control priority between the control units. This paper also proposes methods to determine accurate control commands for AC/DC converters and DERs. By using the proposed method, we can effectively maintain the line voltages in multi-terminal LVDC distribution systems in the normal range. The performance of the proposed voltage control method is evaluated by case studies.

The Study on Correction of Protective Relaying Set Value for the Power Electric Network Paralleled with Wind Farm (풍력전단지의 계통 연계 운전에 따른 보호 계전기 설정치 정정에 관한 고찰)

  • Jang, Sung-Il;Choi, Don-Man;Choi, Jeong-Hwan;Kim, Kwang-Ho;Oh, Jong-Youl;Kim, Joo-Yearl
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.487-490
    • /
    • 2002
  • Wind farm paralleled with electric power network can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the power line with wind farm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator. Consequently, it is difficult to detect the fault happened in the distribution network connected with wind generator. This paper describes the influence of wind turbine generator on the protective relaying system for detecting the fault occurred in a power line network. Simulation results shows that the fault current depends on the fault impedance, location, and the capacity of wind farm and distribution network load.

  • PDF

Impacts of Wind Power Integration on Generation Dispatch in Power Systems

  • Lyu, Jae-Kun;Heo, Jae-Haeng;Kim, Mun-Kyeom;Park, Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.453-463
    • /
    • 2013
  • The probabilistic nature of renewable energy, especially wind energy, increases the needs for new forms of planning and operating with electrical power. This paper presents a novel approach for determining the short-term generation schedule for optimal operations of wind energy-integrated power systems. The proposed probabilistic security-constrained optimal power flow (P-SCOPF) considers dispatch, network, and security constraints in pre- and post-contingency states. The method considers two sources of uncertainty: power demand and wind speed. The power demand is assumed to follow a normal distribution, while the correlated wind speed is modeled by the Weibull distribution. A Monte Carlo simulation is used to choose input variables of power demand and wind speed from their probability distribution functions. Then, P-SCOPF can be applied to the input variables. This approach was tested on a modified IEEE 30-bus system with two wind farms. The results show that the proposed approach provides information on power system economics, security, and environmental parameters to enable better decision-making by system operators.